Literature DB >> 25303908

Novel concave-convex electrode for colonic anastomoses by radiofrequency thermo-fusion.

Lingxi Zhao1, Chengli Song, Zhigang Wang, Yu Zhou, Xinxiang Li, Wei Zhu, Alfred Cuschieri.   

Abstract

BACKGROUND: Successful vascular sealing by radiofrequency (RF)-induced tissue fusion is well established. The present study reports on a novel electrode structure design together with its experimental assessment for RF thermo-fusion of porcine colonic segments.
MATERIALS AND METHODS: Two types of electrode were constructed and used in the present study: one with a conventional smooth surface (S) and the other with a novel reciprocating concave-convex (CC) configuration. Finite element modeling was used to study the thermal distribution profile of the CC electrode. Ex vivo porcine colonic segments were used to create end-to-end serosa-to-serosa colonic anastomoses by applying a pulse of 160 W RF power for 20 s. Different compression pressures (S1, S2, S3) and (C1, C2, C3, C4, C5), were applied, via specially designed ring carriers, to the S and CC electrodes, respectively. Assessment was based on anastomotic burst pressures and histological appearances using light microscopy of paraffin sections.
RESULTS: In total, 22 RF-induced circular anastomoses were performed. Similar burst pressures were observed for anastomoses created by the two types of electrodes (S, CC) performed under the same compression pressure. In contrast, significant differences were observed on histological examination of tissue anastomotic site. In particular, fusion areas between gaps of the CC electrode showed normal histological appearance, while the S electrode produced a completely flat featureless appearance. Furthermore, the CC electrode produced significantly different burst pressures depending on the applied compression pressure during thermo-fusion: compression pressures C1 vs. C4 produced circular anastomotic fusions with burst pressures of 21.9 ± 9.3 vs. 44.6 ± 8.9 mmHg, (p = 0.034); but the burst pressure beyond C4, declined significantly, with C4 vs. C5, burst pressures of 44.6 ± 8.9 vs. 24.7 ± 8.0 mmHg, (p = 0.034).
CONCLUSIONS: The CC electrode exhibits larger and faster thermal diffusion profiles resulting in normal histological appearances in the gaps between CC electrode by protecting tissue from mechanical and thermal damage.

Entities:  

Mesh:

Year:  2014        PMID: 25303908     DOI: 10.1007/s00464-014-3864-4

Source DB:  PubMed          Journal:  Surg Endosc        ISSN: 0930-2794            Impact factor:   4.584


  22 in total

Review 1.  Healing of experimental intestinal anastomoses. Parameters for repair.

Authors:  T Hendriks; W J Mastboom
Journal:  Dis Colon Rectum       Date:  1990-10       Impact factor: 4.585

2.  Thermal fusion: effects and interactions of temperature, compression, and duration variables.

Authors:  Deogracias A G Reyes; Stuart I Brown; Lynda Cochrane; Luisa S Motta; Alfred Cuschieri
Journal:  Surg Endosc       Date:  2012-07-07       Impact factor: 4.584

3.  Bursting strength with various methods of renal artery ligation and potential mechanisms of failure.

Authors:  Sean P Elliott; Andrew B Joel; Maxwell V Meng; Marshall L Stoller
Journal:  J Endourol       Date:  2005-04       Impact factor: 2.942

4.  Efficacy and quality of vessel sealing: comparison of a reusable with a disposable device and effects of clamp surface geometry and structure.

Authors:  S Richter; O Kollmar; M K Schilling; G A Pistorius; M D Menger
Journal:  Surg Endosc       Date:  2006-05-12       Impact factor: 4.584

5.  High-burst-strength, feedback-controlled bipolar vessel sealing.

Authors:  J S Kennedy; P L Stranahan; K D Taylor; J G Chandler
Journal:  Surg Endosc       Date:  1998-06       Impact factor: 4.584

6.  [Prospective study on the use of nickel-titanium temperature-dependent memory-shape device (CAR27) for anastomosis after colorectal surgery].

Authors:  Xin-Xiang Li; San-Jun Cai; Jin Gao; De-Bing Shi; Wei-Li Gu; Zu-Qing Guan; Ye Xu; Fang-Qi Liu; Li-Yong Huang
Journal:  Zhonghua Wei Chang Wai Ke Za Zhi       Date:  2011-05

7.  Factor contributing to leakage of colonic anastomoses.

Authors:  T R Schrock; C W Deveney; J E Dunphy
Journal:  Ann Surg       Date:  1973-05       Impact factor: 12.969

8.  Dynamic aspects of small intestinal rupture with special consideration of anastomotic strength.

Authors:  T S Nelsen; C J Anders
Journal:  Arch Surg       Date:  1966-08

9.  [Application of laparoscopic compression anastomosis clip for laparoscopic gastrointestinal anastomosis].

Authors:  Xin-Xiang Li; Cheng-Zhu Zheng; Kai Yin; Jing-Li Cai; Raul J Rosenthal
Journal:  Zhonghua Wei Chang Wai Ke Za Zhi       Date:  2008-05

10.  Radiofrequency-induced small bowel thermofusion: an ex vivo study of intestinal seal adequacy using mechanical and imaging modalities.

Authors:  Shobhit Arya; Nancy Hadjievangelou; Su Lei; Hiromi Kudo; Robert D Goldin; Ara W Darzi; Daniel S Elson; George B Hanna
Journal:  Surg Endosc       Date:  2013-04-10       Impact factor: 4.584

View more
  2 in total

1.  In silico evaluation of geometry variations with respect to the thermal spread during coagulation of egg white using bipolar vessel sealing instruments.

Authors:  Jay Wagenpfeil; Christina Schöllig; Volker Mayer; Ronny Feuer; Bernhard Nold; Alexander Neugebauer; Michael Ederer; Ralf Rothmund; Bernhard Krämer; Sara Brucker; Markus Enderle; Oliver Sawodny; Julia Rex
Journal:  Biomed Eng Online       Date:  2016-11-02       Impact factor: 2.819

2.  The impedance analysis of small intestine fusion by pulse source.

Authors:  Yifan Wang; Kefu Liu; Xiaowei Xiang; Caihui Zhu; Hao Wang
Journal:  Open Life Sci       Date:  2020-11-03       Impact factor: 0.938

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.