Literature DB >> 25299600

Influence of preparation design on fit and ceramic thickness of CEREC 3 partial ceramic crowns after cementation.

Jae-Hoon Kim1, Byeong-Hoon Cho, Jin-Hee Lee, Soo-Jung Kwon, Young-Ah Yi, Yooseok Shin, Byoung-Duck Roh, Deog-Gyu Seo.   

Abstract

OBJECTIVE: This study investigated the influence of preparation design on the marginal and internal gap and ceramic thickness of partial ceramic crowns (PCCs) fabricated with the CEREC 3 system.
MATERIALS AND METHODS: Sixteen extracted human mandibular molars were prepared according to two different preparation designs (n = 8): a retentive preparation design with traditional cusp capping (Group I) and a non-retentive preparation design with horizontal reduction of cusps (Group II). PCCs were fabricated from IPS Empress CAD with the CEREC 3 system. The parameters for luting space and minimum occlusal ceramic thickness were set to 30 μm and 1.5 mm, respectively. The fabricated PCCs were cemented to their corresponding teeth with self-adhesive resin cement and were then scanned by micro-computed tomography. The marginal and internal gaps were measured at pre-determined measuring points in five bucco-lingual and three mesio-distal cross-sectional images. The ceramic thicknesses of the PCCs were measured at the measuring points for cusp capping areas.
RESULTS: Group II (167.4 ± 76.4 μm) had a smaller overall mean gap, which included the marginal and internal gap measurements, than that of Group I (184.8 ± 89.0 μm). The internal gaps were larger than the marginal gaps, regardless of preparation design. Group I presented a thinner ceramic thickness in the cusp capping areas than the minimum occlusal ceramic thickness parameter of 1.5 mm. CONCLUSION. Preparation design had an influence on fit, particularly the internal gap of the PCCs. Ceramic thickness could be thinner than the minimum ceramic thickness parameter.

Entities:  

Keywords:  CAD/CAM; internal gap; luting space; marginal gap; micro CT

Mesh:

Substances:

Year:  2014        PMID: 25299600     DOI: 10.3109/00016357.2014.956145

Source DB:  PubMed          Journal:  Acta Odontol Scand        ISSN: 0001-6357            Impact factor:   2.331


  4 in total

1.  Marginal and internal fit of nano-composite CAD/CAM restorations.

Authors:  So-Hyun Park; Yeon-Jee Yoo; Yoo-Jin Shin; Byeong-Hoon Cho; Seung-Ho Baek
Journal:  Restor Dent Endod       Date:  2016-01-19

2.  Are different generations of CAD/CAM milling machines capable to produce restorations with similar quality?

Authors:  Renato Roperto; Hussein Assaf; Thiago Soares-Porto; Lisa Lang; Sorin Teich
Journal:  J Clin Exp Dent       Date:  2016-10-01

3.  Comparative evaluation of marginal and internal fit of endocrowns using lithium disilicate and polyetheretherketone computer-aided design - computer-aided manufacturing (CAD-CAM) materials: An in vitro study.

Authors:  Aamir Zahid Godil; Arshi Ilyas Kazi; Sanaa Akhlaq Wadwan; Kashif Yusuf Gandhi; Ramandeep J S Dugal
Journal:  J Conserv Dent       Date:  2021-10-09

4.  Analysis of Self-Adhesive Resin Cement Microshear Bond Strength on Leucite-Reinforced Glass-Ceramic with/without Pure Silane Primer or Universal Adhesive Surface Treatment.

Authors:  Yoon Lee; Jae-Hoon Kim; Jung-Soo Woo; Young-Ah Yi; Ji-Yun Hwang; Deog-Gyu Seo
Journal:  Biomed Res Int       Date:  2015-10-18       Impact factor: 3.411

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.