Large false lumen area is a predictor of failed false lumen volume reduction after stent-graft repair in type B aortic dissection.

Tae-Hoon Kim1, Young-Guk Ko, Sung Woo Kwon, Donghoon Choi, Do Yun Lee, Won-Heum Shim, Min Su Hyon.   

Abstract

PURPOSE: To investigate the predictors of failed false lumen (FL) volume reduction at 12 months after stent-graft implantation in patients with type B aortic dissection.
METHODS: The retrospective analysis comprised 38 patients (25 men; mean age 60±12 years) with double-barrel type B aortic dissection (9 acute) treated with thoracic endovascular aortic repair (TEVAR) and evaluated with serial computed tomography (CT) scans up to 12 months. Aortic volume changes were determined. Based on FL volume change at 1 year after stent-graft implantation, patients were dichotomized according to the presence or absence of FL volume reduction. Clinical and CT variables were compared between groups to determine risk factors of failed FL volume reduction. A major adverse event (MAE) was defined as death or reintervention.
RESULTS: Patients were followed for 4.2±2.8 years. FL volume reduction (+FLVR) occurred in 27 (71%) patients, whereas 11 (29%) patients had no FL volume reduction (-FLVR). The MAE-free survival rate was significantly higher in the +FLVR patients than in the -FLVR group (88.9% vs. 27.3%, respectively; p=0.001). Chronicity of dissection, location of tear site, or the maximum total aortic lumen area was not associated with failure to achieve FL volume reduction. However, the maximum preprocedure FL area was significantly lower in the +FLVR group than in the -FLVR group (12.6±6.6 vs. 21.0±11.4 cm(2), respectively; p=0.041) and was an independent predictor for failed FL volume reduction (odds ratio 1.3, 95% confidence interval 1.02 to 1.70, p=0.031).
CONCLUSION: Failed FL volume reduction after TEVAR was associated with a significantly increased rate of mortality or reintervention during follow-up. A larger preprocedure maximum FL area was a predictor of failed FL volume reduction after TEVAR in type B dissection.

Entities:  

Keywords:  aortic dissection; aortic volume; false lumen; false lumen area; mortality; reintervention; remodeling; stent-graft; thoracic endovascular aortic repair; true lumen; volume reduction

Mesh:

Year:  2014        PMID: 25290799     DOI: 10.1583/14-4671MR.1

Source DB:  PubMed          Journal:  J Endovasc Ther        ISSN: 1526-6028            Impact factor:   3.487


  2 in total

1.  Aortic remodelling after thoracic endovascular aortic repair for acute and subacute type B aortic dissection.

Authors:  Yi Zhou; Wei-Cheng Wang; Xiao-Ming Zhang; Cui Yang; Jing Zheng; Lin Yang; Ling Dong; Xiao Hu; Tao Zhu; Ya-Li Wang; Yan Yang
Journal:  Quant Imaging Med Surg       Date:  2018-05

2.  Comparison of diametric and volumetric changes in Stanford type B aortic dissection patients in assessing aortic remodeling post-stent graft treatment.

Authors:  Wan Naimah Wan Ab Naim; Zhonghua Sun; Yih Miin Liew; Bee Ting Chan; Shirley Jansen; Jing Lei; Poo Balan Ganesan; Shahrul Amry Hashim; Ganiga Srinivasaiah Sridhar; Einly Lim
Journal:  Quant Imaging Med Surg       Date:  2021-05
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.