| Literature DB >> 25289635 |
Abdirahman I Abdi1, Michelle Muthui2, Esther Kiragu2, Peter C Bull3.
Abstract
The level of plasma soluble ICAM-1 (sICAM-1) has been associated with the pathogenesis of several diseases. Previously, a commercial antibody was reported not to recognize an ICAM-1 allele known as ICAM-1kilifi prevalent among African populations. However, that study was based on 19 samples from African Americans of whom 13 had the wild type allele, five heterozygotes and one homozygote. Here, we compare plasma sICAM-1 measures using three different commercial antibodies in samples from Kenyan children genotyped for ICAM-1kilifi allele. We show that two of these antibodies have some degree of deficiency in detecting the ICAM-1kilifi allele. Consideration of the antibody used to measure sICAM-1 is important as up to 30% of the populations in Africa harbour this allele.Entities:
Mesh:
Substances:
Year: 2014 PMID: 25289635 PMCID: PMC4188575 DOI: 10.1371/journal.pone.0108956
Source DB: PubMed Journal: PLoS One ISSN: 1932-6203 Impact factor: 3.240
Figure 1Plasma sICAM-1 in relation to ICAM-1kilifi genotypes.
A. Venn diagram showing the samples used in this study We measured sICAM-1 in 163, 150, and 58 samples using DY720, BMS201MST, and DCD540 ELISA kits. These samples were genotyped from ICAM-1kilifi mutation. Of these, 145 samples have been measured with both BMS201MST and R&D DY720, 52 with R&D DY720 and R&D DCD540, 48 with BMS201MST and R&D DCD540, and 45 with all the three kits. B. Plasma sICAM1 obtained with three different kits relative to ICAM-1kilifi genotypes C. Plasma sICAM-1 in a subset of 45 samples where a measure was obtained with each of the three antibodies used. Measures of plasma sICAM-1 obtained with the BMS201MST, R&D (DCD540) and R&D (DY720) antibodies are depicted in black, red and green triangles respectively. The horizontal bar indicates the median sICAM-1 value. P value was calculated using Cuzick’s test for trend.
Published work done in Africa that measure sICAM-1.
| Article | Kit used to measure sICAM-1 |
| Bellamy R et al, Trans R Soc Trop Med Hyg 1998 | R&D DY720 |
| Tchinda VH et al Acta Trop 2007 | R&D DY720 |
| Conroy AL et al plos One 2010 | R&D DY720 |
| Cserti-Gazdewich CM et al, Malar J. 2010 | R&D DY720 |
| Adukpo, S et al, Plos One 2013 | R&D DY720 |
| Djoba Siawaya JF et al, J infect 2008 | R&D but not specified |
| Park GS et al, J Pediatric Infect Dis Soc 2012 | R&D but not specified |
| Mita-Mendoza, NK et al Plos One 2013 | R&D LAD000 (Human Adhesion Molecule MultiAnalyte Profiling Base Kit) |
| El-Deek S.E et al Med Princ Pract 2013 | Bender MedSystem GmbH, Campus Vienna Biocenter |