Literature DB >> 25283468

Microdamage assessment of bone-cement interfaces under monotonic and cyclic compression.

Gianluca Tozzi1, Qing-Hang Zhang2, Jie Tong2.   

Abstract

Bone-cement interface has been investigated under selected loading conditions, utilising experimental techniques such as in situ mechanical testing and digital image correlation (DIC). However, the role of bone type in the overall load transfer and mechanical behaviour of the bone-cement construct is yet to be fully quantified. Moreover, microdamage accumulation at the interface and in the cement mantle has only been assessed on the exterior surfaces of the samples, where no volumetric information could be obtained. In this study, some typical bone-cement interfaces, representative of different fixation scenarios for both hip and knee replacements, were constructed using mainly trabecular bone, a mixture of trabecular and cortical bone and mainly cortical bone, and tested under static and cyclic compression. Axial displacement and strain fields were obtained by means of digital volume correlation (DVC) and microdamage due to static compression was assessed using DVC and finite element (FE) analysis, where yielded volumes and strains (εzz) were evaluated. A significantly higher load was transferred into the cement region when mainly cortical bone was used to interdigitate with the cement, compared with the other two cases. In the former, progressive damage accumulation under cyclic loading was observed within both the bone-cement interdigitated and the cement regions, as evidenced by the initiation of microcracks associated with high residual strains (εzz_res).
Copyright © 2014 Elsevier Ltd. All rights reserved.

Keywords:  Bone-cement interface; Digital volume correlation; Finite element analysis; In situ mechanical testing; Microdamage; µCT

Mesh:

Substances:

Year:  2014        PMID: 25283468     DOI: 10.1016/j.jbiomech.2014.09.012

Source DB:  PubMed          Journal:  J Biomech        ISSN: 0021-9290            Impact factor:   2.712


  8 in total

1.  3D powder printed tetracalcium phosphate scaffold with phytic acid binder: fabrication, microstructure and in situ X-Ray tomography analysis of compressive failure.

Authors:  Sourav Mandal; Susanne Meininger; Uwe Gbureck; Bikramjit Basu
Journal:  J Mater Sci Mater Med       Date:  2018-03-08       Impact factor: 3.896

2.  Open-porous magnesium-based scaffolds withstand in vitro corrosion under cyclic loading: A mechanistic study.

Authors:  Roxane Bonithon; Colin Lupton; Marta Roldo; Joseph Nicholas Dunlop; Gordon William Blunn; Frank Witte; Gianluca Tozzi
Journal:  Bioact Mater       Date:  2022-04-29

3.  Changes in microgaps, micromotion, and trabecular strain from interlocked cement-trabecular bone interfaces in total knee replacements with in vivo service.

Authors:  Mark A Miller; Jacklyn R Goodheart; Benjamin Khechen; Dennis Janssen; Kenneth A Mann
Journal:  J Orthop Res       Date:  2015-12-10       Impact factor: 3.494

4.  Experimental and computational micromechanics at the tibial cement-trabeculae interface.

Authors:  Priyanka Srinivasan; Mark A Miller; Nico Verdonschot; Kenneth A Mann; Dennis Janssen
Journal:  J Biomech       Date:  2016-04-02       Impact factor: 2.712

Review 5.  Digital volume correlation for the characterization of musculoskeletal tissues: Current challenges and future developments.

Authors:  Enrico Dall'Ara; Gianluca Tozzi
Journal:  Front Bioeng Biotechnol       Date:  2022-10-04

6.  Full-Field Strain Uncertainties and Residuals at the Cartilage-Bone Interface in Unstained Tissues Using Propagation-Based Phase-Contrast XCT and Digital Volume Correlation.

Authors:  Gianluca Tozzi; Marta Peña Fernández; Sarah Davis; Aikaterina Karali; Alexander Peter Kao; Gordon Blunn
Journal:  Materials (Basel)       Date:  2020-06-05       Impact factor: 3.623

7.  Sub-trabecular strain evolution in human trabecular bone.

Authors:  Mikael J Turunen; Sophie Le Cann; Erika Tudisco; Goran Lovric; Alessandra Patera; Stephen A Hall; Hanna Isaksson
Journal:  Sci Rep       Date:  2020-08-14       Impact factor: 4.379

8.  Measurement of Internal Implantation Strains in Analogue Bone Using DVC.

Authors:  Alexander Marter; Charles Burson-Thomas; Alexander Dickinson; Kathryn Rankin; Mark Mavrogordato; Fabrice Pierron; Martin Browne
Journal:  Materials (Basel)       Date:  2020-09-12       Impact factor: 3.623

  8 in total