Literature DB >> 25281968

Denoised and texture enhanced MVCT to improve soft tissue conspicuity.

Ke Sheng1, Shuiping Gou2, Jiaolong Wu3, Sharon X Qi1.   

Abstract

PURPOSE: MVCT images have been used in TomoTherapy treatment to align patients based on bony anatomies but its usefulness for soft tissue registration, delineation, and adaptive radiation therapy is limited due to insignificant photoelectric interaction components and the presence of noise resulting from low detector quantum efficiency of megavoltage x-rays. Algebraic reconstruction with sparsity regularizers as well as local denoising methods has not significantly improved the soft tissue conspicuity. The authors aim to utilize a nonlocal means denoising method and texture enhancement to recover the soft tissue information in MVCT (DeTECT).
METHODS: A block matching 3D (BM3D) algorithm was adapted to reduce the noise while keeping the texture information of the MVCT images. Following imaging denoising, a saliency map was created to further enhance visual conspicuity of low contrast structures. In this study, BM3D and saliency maps were applied to MVCT images of a CT imaging quality phantom, a head and neck, and four prostate patients. Following these steps, the contrast-to-noise ratios (CNRs) were quantified.
RESULTS: By applying BM3D denoising and saliency map, postprocessed MVCT images show remarkable improvements in imaging contrast without compromising resolution. For the head and neck patient, the difficult-to-see lymph nodes and vein in the carotid space in the original MVCT image became conspicuous in DeTECT. For the prostate patients, the ambiguous boundary between the bladder and the prostate in the original MVCT was clarified. The CNRs of phantom low contrast inserts were improved from 1.48 and 3.8 to 13.67 and 16.17, respectively. The CNRs of two regions-of-interest were improved from 1.5 and 3.17 to 3.14 and 15.76, respectively, for the head and neck patient. DeTECT also increased the CNR of prostate from 0.13 to 1.46 for the four prostate patients. The results are substantially better than a local denoising method using anisotropic diffusion.
CONCLUSIONS: The authors showed that it is feasible to extract more soft tissue contrast information from the noisy MVCT images using a nonlocal means 3D block matching method in combination with saliency maps, revealing information that was originally unperceivable to human observers.

Entities:  

Mesh:

Year:  2014        PMID: 25281968     DOI: 10.1118/1.4894714

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  10 in total

1.  Low-dose CT via convolutional neural network.

Authors:  Hu Chen; Yi Zhang; Weihua Zhang; Peixi Liao; Ke Li; Jiliu Zhou; Ge Wang
Journal:  Biomed Opt Express       Date:  2017-01-09       Impact factor: 3.732

2.  Low-Dose CT With a Residual Encoder-Decoder Convolutional Neural Network.

Authors:  Hu Chen; Yi Zhang; Mannudeep K Kalra; Feng Lin; Yang Chen; Peixi Liao; Jiliu Zhou; Ge Wang
Journal:  IEEE Trans Med Imaging       Date:  2017-06-13       Impact factor: 10.048

3.  Nonlocal Means Denoising of Self-Gated and k-Space Sorted 4-Dimensional Magnetic Resonance Imaging Using Block-Matching and 3-Dimensional Filtering: Implications for Pancreatic Tumor Registration and Segmentation.

Authors:  Jun Jin; Elizabeth McKenzie; Zhaoyang Fan; Richard Tuli; Zixin Deng; Jianing Pang; Benedick Fraass; Debiao Li; Howard Sandler; Guang Yang; Ke Sheng; Shuiping Gou; Wensha Yang
Journal:  Int J Radiat Oncol Biol Phys       Date:  2016-02-06       Impact factor: 7.038

4.  Technical Note: Iterative megavoltage CT (MVCT) reconstruction using block-matching 3D-transform (BM3D) regularization.

Authors:  Qihui Lyu; Chunlin Yang; Hao Gao; Yi Xue; Daniel O'Connor; Tianye Niu; Ke Sheng
Journal:  Med Phys       Date:  2018-04-30       Impact factor: 4.071

5.  Low-dose computed tomography image reconstruction via a multistage convolutional neural network with autoencoder perceptual loss network.

Authors:  Qing Li; Saize Li; Runrui Li; Wei Wu; Yunyun Dong; Juanjuan Zhao; Yan Qiang; Rukhma Aftab
Journal:  Quant Imaging Med Surg       Date:  2022-03

6.  A post-processing method based on interphase motion correction and averaging to improve image quality of 4D magnetic resonance imaging: a clinical feasibility study.

Authors:  Zixin Deng; Jianing Pang; Yi Lao; Xiaoming Bi; Guan Wang; Yuhua Chen; Matthias Fenchel; Richard Tuli; Debiao Li; Wensha Yang; Zhaoyang Fan
Journal:  Br J Radiol       Date:  2019-01-03       Impact factor: 3.039

7.  Radiation-induced CT number changes in GTV and parotid glands during the course of radiation therapy for nasopharyngeal cancer.

Authors:  Shouping Xu; Zhaoxia Wu; Cungeng Yang; Lin Ma; Baolin Qu; Guangpei Chen; Weirong Yao; Shi Wang; Yaqiang Liu; X Allen Li
Journal:  Br J Radiol       Date:  2016-04-01       Impact factor: 3.039

8.  Four-Dimensional Magnetic Resonance Imaging With 3-Dimensional Radial Sampling and Self-Gating-Based K-Space Sorting: Early Clinical Experience on Pancreatic Cancer Patients.

Authors:  Wensha Yang; Zhaoyang Fan; Richard Tuli; Zixin Deng; Jianing Pang; Ashley Wachsman; Robert Reznik; Howard Sandler; Debiao Li; Benedick A Fraass
Journal:  Int J Radiat Oncol Biol Phys       Date:  2015-08-21       Impact factor: 7.038

9.  Improved contrast and noise of megavoltage computed tomography (MVCT) through cycle-consistent generative machine learning.

Authors:  Luciano Vinas; Jessica Scholey; Martina Descovich; Vasant Kearney; Atchar Sudhyadhom
Journal:  Med Phys       Date:  2020-12-27       Impact factor: 4.071

10.  Stacked competitive networks for noise reduction in low-dose CT.

Authors:  Wenchao Du; Hu Chen; Zhihong Wu; Huaiqiang Sun; Peixi Liao; Yi Zhang
Journal:  PLoS One       Date:  2017-12-21       Impact factor: 3.240

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.