Literature DB >> 25278722

Comparative study between real time three dimensional echocardiogram and angiography in evaluation of patent ductus arteriosus, single center experience.

Raghda Ghonimy Elsheikh1, Ahmed Z Darweish1, Mohamed Elsetiha1, Hazem Kamel1.   

Abstract

UNLABELLED: In this study we compared the real time three dimensional echocardiogram data in evaluation of patent ductus arteriosus with the gold standard angiography.
METHODS: This study included 25 patients with PDA referred to Tanta University Hospital for elective cardiac catheterization. The patients comprised seven males and 18 females, with a mean age of 3.7 ± 0.36 years. The study duration was six months. All patients underwent full 2D echocardiogram as well as real time three-dimensional echocardiogram (RT3DE). Essential measurements included the pulmonary end of the duct, duct length, aortic end and aortic ampulla as well as the anatomical type of the PDA. Data obtained by RT3DE were compared against 2D echocardiogram and angiography.
RESULTS: There was no significant difference between 3D echocardiogram and angiography (P = 0.001) in the pulmonary end of the duct measurement. Neither were there any significant differences between the length of the duct or the aortic end measured by 3D echocardiogram and by angiography (P = 0.001 in both). While there was adequate agreement between both 2D and 3D echocardiogram and angiography in determining the anatomical type of the PDA, 3D echocardiogram determined type A and type E ductus more accurately than 2D echocardiogram. The feasibility of Q lab analysis of PDA was 96%, while the feasibility of gated color flow 3D acquisitions in determining anatomical types was 64%.
CONCLUSION: There was complete agreement on location, size, morphology and surrounding structure of PDA between 2D and 3D echocardiogram, and angiography. This result illustrates the need for the proper placement of the device in catheterization laboratories.

Entities:  

Keywords:  3D echocardiography; Amplatzer duct occluder; Patent ductous arteriosus

Year:  2014        PMID: 25278722      PMCID: PMC4179891          DOI: 10.1016/j.jsha.2014.02.005

Source DB:  PubMed          Journal:  J Saudi Heart Assoc        ISSN: 1016-7315


  12 in total

1.  Finding genetic contributions to sporadic disease: a recessive locus at 12q24 commonly contributes to patent ductus arteriosus.

Authors:  Arya Mani; Seyed-Mahmoud Meraji; Roozbeh Houshyar; Jayaram Radhakrishnan; Alaleh Mani; Mehrabeh Ahangar; Tayebeh M Rezaie; Mohammad-Ali Taghavinejad; Behrooz Broumand; Hongyu Zhao; Carol Nelson-Williams; Richard P Lifton
Journal:  Proc Natl Acad Sci U S A       Date:  2002-10-30       Impact factor: 11.205

2.  Live three-dimensional transthoracic echocardiographic delineation of patent ductus arteriosus.

Authors:  Ashish Sinha; Navin C Nanda; Deepak Khanna; Fikret Ilgenli; Maninder Sidhu; Steven G Lloyd; Himanshu Gupta; Benigno Soto; James K Kirklin
Journal:  Echocardiography       Date:  2004-07       Impact factor: 1.724

3.  Multiplanar review of three-dimensional echocardiography gives new insights into the morphology of Ebstein's malformation.

Authors:  Tara Bharucha; Robert H Anderson; Zek S Lim; Joseph J Vettukattil
Journal:  Cardiol Young       Date:  2010-01-19       Impact factor: 1.093

4.  Practical guide for three-dimensional transthoracic echocardiography using a fully sampled matrix array transducer.

Authors:  Hyun Suk Yang; Ramesh C Bansal; Farouk Mookadam; Bijoy K Khandheria; A Jamil Tajik; Krishnaswamy Chandrasekaran
Journal:  J Am Soc Echocardiogr       Date:  2008-09       Impact factor: 5.251

5.  Clinically silent patent ductus arteriosus.

Authors:  T R Lloyd; R H Beekman
Journal:  Am Heart J       Date:  1994-06       Impact factor: 4.749

6.  Real-time 3-dimensional echocardiography in assessing atrial and ventricular septal defects: an echocardiographic-surgical correlative study.

Authors:  Tsung O Cheng; Ming-Xing Xie; Xin-Fang Wang; Ying Wang; Qing Lu
Journal:  Am Heart J       Date:  2004-12       Impact factor: 4.749

7.  Visualization of patent ductus arteriosus using real-time three-dimensional echocardiogram: Comparative study with 2D echocardiogram and angiography.

Authors:  Alaa Roushdy; Azza El Fiky; Dina Ezz El Din
Journal:  J Saudi Heart Assoc       Date:  2012-02-13

Review 8.  The Sideris buttoned devices for transcatheter closure of patent ductus arteriosus.

Authors:  E B Sideris; P S Rao; R Zamora
Journal:  J Interv Cardiol       Date:  2001-04       Impact factor: 2.279

Review 9.  The incidence of congenital heart disease.

Authors:  Julien I E Hoffman; Samuel Kaplan
Journal:  J Am Coll Cardiol       Date:  2002-06-19       Impact factor: 24.094

10.  Impact of multiplanar review of three-dimensional echocardiographic data on management of congenital heart disease.

Authors:  Tara Bharucha; Kevin S Roman; Robert H Anderson; Joseph J Vettukattil
Journal:  Ann Thorac Surg       Date:  2008-09       Impact factor: 4.330

View more
  1 in total

1.  Is transcatheter closure superior to surgical ligation of patent ductus arteriosus among Nigerian Children?

Authors:  Barakat Adeola Animasahun; Motunrayo O Adekunle; Olabode Falase; Mohammed Tunde Gidado; Olusola Y Kusimo; Michael O Sanusi; Adeyemi Johnson
Journal:  Afr J Paediatr Surg       Date:  2018 Apr-Jun
  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.