Simple and robust ICP-MS method for simultaneous determination of serum Co and Cr in routine clinical practice.

Hyun-Jung Choi1, Seung-Jae Lim2, Youn-Soo Park3, Soo-Youn Lee4.   

Abstract

BACKGROUND: Chromium (Cr) and cobalt (Co) metal ions released from orthopedic prostheses, such as metal-on-metal (MoM) bearings, may be related to wear of the bearing surface. These ions may serve as indicators of the in vivo performance of MoM bearing surfaces. We developed a simple and sensitive assay suitable for the simultaneous measurement of serum Cr and Co using inductively coupled plasma-mass spectrometry (ICP-MS) in clinical routine laboratory practice to evaluate analytical performance and clinical utility.
METHODS: We evaluated the linearity, precision, and lower limit of quantification (LOQ) of an ICP-MS method to determine serum Cr and Co concentration in accordance with U.S. Food and Drug Administration guidance for bioanalytical method validation. This method was used to determine the serum Cr and Co levels of 236 clinical samples from 74 patients with MoM hip prosthesis and 51 healthy controls.
RESULTS: The assay showed good linearity (0-20 μg/l, r(2)>0.999) and satisfactory accuracy for all tested concentrations of Cr and Co (%bias, -1.5% to 2.5%, -3.3% to 1.6%, respectively). The CVs for both metal ions were <10% for LOQ (0.02 μg/l Cr, 0.01 μg/l Co) and within 5% for other concentrations (intra- and inter-assay CV, 1.2-2.6 and 1.9-4.4% of Cr; 1.4-2.7 and 1.9-4.7% of Co). The serum Cr and Co concentrations (mean ± SD) were 0.60 ± 0.12 μg/l and 0.29 ± 0.15 μg/l in 51 healthy subjects. In 74 patients (185 serum samples) after HRA (median duration implanted, 48 months; range, 1-138 months), the concentrations of Cr and Co were 2.75 μg/l (range, 0.61-116.80 μg/l) and 1.49 μg/l (range, 0.12-127.80 μg/l), respectively.
CONCLUSIONS: ICP-MS can simultaneously quantify serum Cr and Co levels with suitable analytical performance including a wide analytical range and very low LOQ. This assay will be very useful for evaluating the nutritional status of Cr and Co in healthy humans as well as monitoring the performance of orthopedic prostheses after hip resurfacing arthroplasty.
Copyright © 2014 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Arthroplasty; Chromium; Cobalt; ICP-MS

Mesh:

Substances:

Year:  2014        PMID: 25278349     DOI: 10.1016/j.cca.2014.09.019

Source DB:  PubMed          Journal:  Clin Chim Acta        ISSN: 0009-8981            Impact factor:   3.786


  3 in total

1.  Potential presence of metals in patients treated with metal-metal coupling prostheses for hip arthroplasty at 7 and 10 years of follow-up.

Authors:  Giuseppe Sessa; Gianluca Testa; Salvatore Gioitta Iachino; Luciano Costarella; Calogero Puma Pagliarello; Margherita Ferrante; Alfina Grasso; Vito Pavone
Journal:  Eur J Orthop Surg Traumatol       Date:  2018-01-22

2.  Reference values for trace essential elements in the whole blood and serum samples of the adult Serbian population: significance of selenium deficiency.

Authors:  Aleksandar Stojsavljević; Jovana Jagodić; Ljiljana Vujotić; Slavica Borković-Mitić; Zorica Rašić-Milutinović; Dragana Jovanović; Marija Gavrović-Jankulović; Dragan Manojlović
Journal:  Environ Sci Pollut Res Int       Date:  2019-11-20       Impact factor: 4.223

3.  Serum Concentrations of Trace Elements in Patients with Tuberculosis and Its Association with Treatment Outcome.

Authors:  Rihwa Choi; Hyoung-Tae Kim; Yaeji Lim; Min-Ji Kim; O Jung Kwon; Kyeongman Jeon; Hye Yun Park; Byeong-Ho Jeong; Won-Jung Koh; Soo-Youn Lee
Journal:  Nutrients       Date:  2015-07-21       Impact factor: 5.717

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.