Literature DB >> 25275961

Raman spectroscopic assessment of degree of conversion of bulk-fill resin composites--changes at 24 hours post cure.

M Par, O Gamulin, D Marovic, E Klaric, Z Tarle.   

Abstract

OBJECTIVE: The aim of this study was to determine degree of conversion (DC) of solid and flowable bulk-fill composites immediately and after 24 hours and investigate the variations of DC at surface and depths up to 4 mm.
MATERIALS AND METHODS: Eight bulk-fill composites (Tetric EvoCeram Bulk Fill [shades IVA and IVB], Quixfil, X-tra fil, Venus Bulk Fill, X-tra Base, SDR, Filtek Bulk Fill) were investigated, and two conventional composites (GrandioSO, X-Flow) were used as controls. The samples (n = 5) were cured for 20 seconds with irradiance of 1090 mW/cm(2). Raman spectroscopic measurements were made immediately after curing on sample surfaces and after 24 hours of dark storage at surface and at incremental depths up to 4 mm. Mean DC values were compared using repeated measures analysis of variance (ANOVA) and t-test for dependent samples.
RESULTS: Surface DC values immediately after curing ranged from 59.1%-71.8%, while the 24-hour postcure values ranged from 71.3%-86.1%. A significant increase of DC was observed 24 hours post cure for all bulk-fill composites, which amounted from 11.3% to 16.9%. Decrease of DC through depths up to 4 mm varied widely among bulk-fill composites and ranged from 2.9% to 19.7%.
CONCLUSIONS: All bulk-fill composites presented a considerable 24-hour postcure DC increase and clinically acceptable DC at depths up to 4 mm. Conventional control composites were sufficiently cured only up to 2 mm, despite significant postcure polymerization.

Entities:  

Mesh:

Substances:

Year:  2014        PMID: 25275961     DOI: 10.2341/14-091-L

Source DB:  PubMed          Journal:  Oper Dent        ISSN: 0361-7734            Impact factor:   2.440


  20 in total

1.  Long Term Degree of Conversion of two Bulk-Fill Composites.

Authors:  Matej Par; Matea Lapas-Barisic; Ozren Gamulin; Vlatko Panduric; Nika Spanovic; Zrinka Tarle
Journal:  Acta Stomatol Croat       Date:  2016-12

2.  Three-year clinical evaluation of class II posterior composite restorations placed with different techniques and flowable composite linings in endodontically treated teeth.

Authors:  Emel Karaman; Busra Keskin; Ugur Inan
Journal:  Clin Oral Investig       Date:  2016-08-19       Impact factor: 3.573

3.  Comparative Evaluation of the Depth of Cure and Degree of Conversion of Two Bulk Fill Flowable Composites.

Authors:  Ca Anand Yokesh; P Hemalatha; M Muthalagu; M Robert Justin
Journal:  J Clin Diagn Res       Date:  2017-08-01

4.  Microleakage of "Bulk-Fill" Composite Resin for Class II Restorations Pretreated With CO2 Laser in Deciduous Molars: An In Vitro Study.

Authors:  Larissa Costa Santos; Ravana Angelini Sfalcin; Eugenio José Garcia; Fátima Antônia Aparecida Zanin; Aldo Brugnera Junior; Daniela Fátima Teixeira Silva; Anna Carolina Ratto Tempestini Horliana; Kristianne Porta Santos Fernandes; Raquel Agnelli Mesquita-Ferrari; Sandra Kalil Bussadori
Journal:  J Lasers Med Sci       Date:  2019-10-01

5.  Effect of double-layer application on the early enamel bond strength of universal adhesives.

Authors:  Eizo Hirokane; Toshiki Takamizawa; Yuta Kasahara; Ryo Ishii; Akimasa Tsujimoto; Wayne W Barkmeier; Mark A Latta; Masashi Miyazaki
Journal:  Clin Oral Investig       Date:  2020-05-30       Impact factor: 3.573

6.  In vitro antibacterial and remineralizing effect of adhesive containing triazine and niobium pentoxide phosphate inverted glass.

Authors:  Aline Segatto Pires Altmann; Fabrício Mezzomo Collares; Vicente Castelo Branco Leitune; Rodrigo Alex Arthur; Antonio Shigueaki Takimi; Susana Maria Werner Samuel
Journal:  Clin Oral Investig       Date:  2016-02-19       Impact factor: 3.573

7.  Marginal microleakage and modified microtensile bond strength of Activa Bioactive, in comparison with conventional restorative materials.

Authors:  Saba Tohidkhah; Hamid Kermanshah; Elham Ahmadi; Behnous Jalalian; Ladan Ranjbar Omrani
Journal:  Clin Exp Dent Res       Date:  2022-01-17

8.  Evaluation of the influence of light-curing units on the degree of conversion in depth of a bulk-fill resin.

Authors:  Fernanda-Midori Tsuzuki; Lidiane-Vizioli de Castro-Hoshino; Larissa-Coelho-Pires Lopes; Francielle Sato; Mauro-Luciano Baesso; Raquel-Sano-Suga Terada
Journal:  J Clin Exp Dent       Date:  2020-12-01

9.  Repair Bond Strength of Aged Resin Composite after Different Surface and Bonding Treatments.

Authors:  Michael Wendler; Renan Belli; Reinhard Panzer; Daniel Skibbe; Anselm Petschelt; Ulrich Lohbauer
Journal:  Materials (Basel)       Date:  2016-07-07       Impact factor: 3.623

10.  Methacrylate peak determination and selection recommendations using ATR-FTIR to investigate polymerisation of dental methacrylate mixtures.

Authors:  António H S Delgado; Anne M Young
Journal:  PLoS One       Date:  2021-06-09       Impact factor: 3.240

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.