Evaluation of bioaerosol exposures during hospital bronchoscopy examinations.

Jacques Lavoie1, Geneviève Marchand, Yves Cloutier, Stéphane Hallé, Sylvie Nadeau, Caroline Duchaine, Gilbert Pichette.   

Abstract

During hospital bronchoscopy examinations, aerosols emitted from the patient's during coughing can be found suspended in the ambient air. The aerosols can contain pathogenic microorganisms. Depending on their size, these microorganisms can remain in the air for a long time. The objective of this study was to measure the sizes and concentrations of the biological and non-biological particles produced during bronchoscopy examinations, and to propose preventive or corrective measures. Two bronchoscopy rooms were studied. An aerodynamic particle sizer (UV-APS) was used to establish the concentrations of the particles present and their size distributions. This instrument determines the aerodynamic diameter of the aerosols and can distinguish fluorescent (bioaerosols) and non-fluorescent particles. Reference concentrations were measured before the start of the examinations (morning background concentrations). They were used as comparison levels for the concentrations measured during and at the end of the bronchoscopies. In parallel, computational fluid dynamics (CFD) made it possible to isolate and understand different factors that can affect the concentration levels in bronchoscopy rooms. The concentrations of the non-fluorescent and fluorescent particles (bioaerosols) were significantly higher (p ≤ 0.05) during the bronchoscopy examinations than the reference concentrations. For the investigated factors, the bioaerosol concentrations were significantly higher during bronchoscope insertion tasks. The time required at the end of the day for the bioaerosols to reach the morning reference concentrations was about fifteen minutes. The average particle sizes were 2.9 μm for the fluorescent particles (bioaerosols) and 0.9 μm for the non-fluorescent particles. Our models based on computational fluid dynamics (CFD) enabled us to observe the behaviour of aerosols for the different rooms.

Entities:  

Mesh:

Substances:

Year:  2015        PMID: 25275615     DOI: 10.1039/c4em00359d

Source DB:  PubMed          Journal:  Environ Sci Process Impacts        ISSN: 2050-7887            Impact factor:   4.238


  8 in total

1.  Application of ATP-based bioluminescence for bioaerosol quantification: effect of sampling method.

Authors:  Taewon Han; Melody Wren; Kelsey DuBois; Jennifer Therkorn; Gediminas Mainelis
Journal:  J Aerosol Sci       Date:  2015-12-01       Impact factor: 3.433

Review 2.  Negative pressure of the environmental air in the cleaning area of the materials and sterilization center: a systematic review.

Authors:  Caroline Lopes Ciofi-Silva; Lisbeth Lima Hansen; Alda Graciele Claudio Dos Santos Almeida; Julia Yaeko Kawagoe; Maria Clara Padoveze; Kazuko Uchikawa Graziano
Journal:  Rev Lat Am Enfermagem       Date:  2016-09-01

3.  Characterization of Experimental and Clinical Bioaerosol Generation During Potential Aerosol-Generating Procedures.

Authors:  Nathan Doggett; Chung-Wai Chow; Samira Mubareka
Journal:  Chest       Date:  2020-07-21       Impact factor: 9.410

4.  Potential for occupational exposures to pathogens during bronchoscopy procedures.

Authors:  Maryshe Zietsman; Linh T Phan; Rachael M Jones
Journal:  J Occup Environ Hyg       Date:  2019-08-13       Impact factor: 2.155

5.  Intraluminal gas escape from biopsy valves and endoscopic devices during endoscopy: caution advised during the COVID-19 era.

Authors:  Shinya Urakawa; Teijiro Hirashita; Kota Momose; Makoto Nishimura; Kiyokazu Nakajima; Jeffrey W Milsom
Journal:  Endosc Int Open       Date:  2021-02-19

Review 6.  Safe performance of diagnostic bronchoscopy/EBUS during the SARS-CoV-2 pandemic.

Authors:  Daniel P Steinfort; Felix J F Herth; Louis B Irving; Phan T Nguyen
Journal:  Respirology       Date:  2020-05-13       Impact factor: 6.175

7.  A tracing method of airborne bacteria transmission across built environments.

Authors:  Zonggang Li; Hongning Wang; Weichao Zheng; Baoming Li; Yongxiang Wei; Jinxin Zeng; Changwei Lei
Journal:  Build Environ       Date:  2019-08-09       Impact factor: 6.456

Review 8.  Severe acute respiratory syndrome coronavirus 2 infection risk during elective peri-operative care: a narrative review.

Authors:  J Schutzer-Weissmann; D J Magee; P Farquhar-Smith
Journal:  Anaesthesia       Date:  2020-08-26       Impact factor: 12.893

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.