Literature DB >> 25274161

Feasibility and analysis of bipolar concentric recording of electrohysterogram with flexible active electrode.

Y Ye-Lin1, J Alberola-Rubio, G Prats-Boluda, A Perales, D Desantes, Javier Garcia-Casado.   

Abstract

The conduction velocity and propagation patterns of the electrohysterogram (EHG) provide fundamental information on the electrophysiological condition of the uterus. However, the accuracy of these measurements can be impaired by both the poor spatial selectivity and sensitivity to the relative direction of the contraction propagation associated with conventional disc electrodes. Concentric ring electrodes could overcome these limitations. The aim of this study was to examine the feasibility of picking up surface EHG signals using a new flexible tripolar concentric ring electrode (TCRE), and to compare these signals with conventional bipolar recordings. Simultaneous recording of conventional bipolar signals and bipolar concentric EHG (BC-EHG) were carried out on 22 pregnant women. Signal bursts were characterized and compared. No significant differences were found between the channels in either duration or dominant frequency in the Fast Wave High frequency range. Nonetheless, the high pass filtering effect of the BC-EHG recordings gave lower frequency content between 0.1 and 0.2 Hz. Although the BC-EHG signal amplitude was about 5-7 times smaller than that of bipolar recordings, a similar signal-to-noise ratio was obtained. These results suggest that the flexible TCRE is able to pick up uterine electrical activity and could provide additional information for deducing the uterine electrophysiological condition.

Entities:  

Mesh:

Year:  2014        PMID: 25274161     DOI: 10.1007/s10439-014-1130-5

Source DB:  PubMed          Journal:  Ann Biomed Eng        ISSN: 0090-6964            Impact factor:   3.934


  10 in total

1.  Textile Concentric Ring Electrodes for ECG Recording Based on Screen-Printing Technology.

Authors:  José Vicente Lidón-Roger; Gema Prats-Boluda; Yiyao Ye-Lin; Javier Garcia-Casado; Eduardo Garcia-Breijo
Journal:  Sensors (Basel)       Date:  2018-01-21       Impact factor: 3.576

2.  Evaluation of Bipolar, Tripolar, and Quadripolar Laplacian Estimates of Electrocardiogram via Concentric Ring Electrodes.

Authors:  Javier Garcia-Casado; Yiyao Ye-Lin; Gema Prats-Boluda; Oleksandr Makeyev
Journal:  Sensors (Basel)       Date:  2019-08-31       Impact factor: 3.576

3.  Evaluation of Swallowing Related Muscle Activity by Means of Concentric Ring Electrodes.

Authors:  J Garcia-Casado; G Prats-Boluda; Y Ye-Lin; S Restrepo-Agudelo; E Perez-Giraldo; A Orozco-Duque
Journal:  Sensors (Basel)       Date:  2020-09-15       Impact factor: 3.576

Review 4.  Electrodes in external electrohysterography: a systematic literature review.

Authors:  Thierry R Jossou; Aziz Et-Tahir; Zakaria Tahori; Abdelmajid El Ouadi; Daton Medenou; Abdelmajid Bybi; Latif Fagbemi; Mohamed Sbihi; Davide Piaggio
Journal:  Biophys Rev       Date:  2021-05-09

5.  Optimized Feature Subset Selection Using Genetic Algorithm for Preterm Labor Prediction Based on Electrohysterography.

Authors:  Félix Nieto-Del-Amor; Gema Prats-Boluda; Jose Luis Martinez-De-Juan; Alba Diaz-Martinez; Rogelio Monfort-Ortiz; Vicente Jose Diago-Almela; Yiyao Ye-Lin
Journal:  Sensors (Basel)       Date:  2021-05-12       Impact factor: 3.576

6.  Improving the Accuracy of Laplacian Estimation with Novel Variable Inter-Ring Distances Concentric Ring Electrodes.

Authors:  Oleksandr Makeyev; Walter G Besio
Journal:  Sensors (Basel)       Date:  2016-06-10       Impact factor: 3.576

7.  A Flexible Multiring Concentric Electrode for Non-Invasive Identification of Intestinal Slow Waves.

Authors:  Victor Zena-Giménez; Javier Garcia-Casado; Yiyao Ye-Lin; Eduardo Garcia-Breijo; Gema Prats-Boluda
Journal:  Sensors (Basel)       Date:  2018-01-30       Impact factor: 3.576

8.  Propagation of spontaneous electrical activity in the ex vivo human uterus.

Authors:  Nienke P M Kuijsters; Federica Sammali; Xin Ye; Celine Blank; Lin Xu; Massimo Mischi; Benedictus C Schoot; Chiara Rabotti
Journal:  Pflugers Arch       Date:  2020-07-20       Impact factor: 3.657

9.  A Comparative Study of Vaginal Labor and Caesarean Section Postpartum Uterine Myoelectrical Activity.

Authors:  Alba Diaz-Martinez; Javier Mas-Cabo; Gema Prats-Boluda; Javier Garcia-Casado; Karen Cardona-Urrego; Rogelio Monfort-Ortiz; Angel Lopez-Corral; Maria De Arriba-Garcia; Alfredo Perales; Yiyao Ye-Lin
Journal:  Sensors (Basel)       Date:  2020-05-26       Impact factor: 3.576

10.  Solving the general inter-ring distances optimization problem for concentric ring electrodes to improve Laplacian estimation.

Authors:  Oleksandr Makeyev
Journal:  Biomed Eng Online       Date:  2018-08-30       Impact factor: 2.819

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.