Endoscopic ultrasound-guided placement of plastic vs. biflanged metal stents for therapy of walled-off necrosis: a retrospective single-center series.

Shuntaro Mukai1, Takao Itoi1, Todd H Baron2, Atsushi Sofuni1, Fumihide Itokawa1, Toshio Kurihara1, Takayoshi Tsuchiya1, Kentaro Ishii1, Shujiro Tsuji1, Nobuhito Ikeuchi1, Reina Tanaka1, Junko Umeda1, Ryosuke Tonozuka1, Mitsuyoshi Honjo1, Takuji Gotoda1, Fuminori Moriyasu1, Ichiro Yasuda3.   

Abstract

BACKGROUND AND STUDY AIMS: Recently, a novel fully covered and biflanged metal stent (BFMS)dedicated to the drainage of walled-off necrosis(WON) was developed. The aim of this study was to retrospectively evaluate the safety, efficacy, and cost performance of drainage of WON using the novel BFMS compared with a traditional plastic stent. PATIENTS AND METHODS: A total of 70 patients with symptomatic WON were treated under endoscopic ultrasound (EUS) guidance. Initial drainage was conducted using the single gateway technique with placement of one or more plastic stents or a single BFMS.If drainage was unsuccessful,direct endoscopic necrosectomy (DEN)was performed.
RESULTS: There were no statistically significant differences in rates of technical success, clinical success,and adverse events between plastics stents and BFMS, despite the size of WON in the BFMS group being significantly larger than that in the plastic stent group (105.6 vs. 77.1 mm; P=0.003).The mean procedure times for the first EUS-guided drainage and for re-intervention were significantly shorter in the BFMS group than in the plastic stent group (28.8±7.1 vs. 42.6±14.2, respectively,for drainage, P<0.001; and 34.9±8.5 vs.41.8±7.6, respectively, for re-intervention, P<0.001). There was no statistically significant difference in the total cost between plastic stent and BFMS use in the treatment of WON ($5352vs. $6274; P=0.25).
CONCLUSIONS: Plastic stents and BFMS were safe and effective for the treatment of WON. In particular,BFMS placement appeared to be preferable for initial EUS-guided drainage and additional reintervention(e.g. DEN) as it reduced the procedure time. Prospective randomized controlled trials are warranted.

Entities:  

Mesh:

Substances:

Year:  2014        PMID: 25264765     DOI: 10.1055/s-0034-1377966

Source DB:  PubMed          Journal:  Endoscopy        ISSN: 0013-726X            Impact factor:   10.093


  39 in total

1.  Electrocautery vs non-electrocautery dilation catheters in endoscopic ultrasonography-guided pancreatic fluid collection drainage.

Authors:  Katsuya Kitamura; Akira Yamamiya; Yu Ishii; Tomohiro Nomoto; Tadashi Honma; Hitoshi Yoshida
Journal:  World J Gastrointest Endosc       Date:  2016-07-10

2.  Management of acute pancreatitis in Japan: Analysis of nationwide epidemiological survey.

Authors:  Shin Hamada; Atsushi Masamune; Tooru Shimosegawa
Journal:  World J Gastroenterol       Date:  2016-07-28       Impact factor: 5.742

Review 3.  Efficacy and safety of metallic stents in comparison to plastic stents for endoscopic drainage of peripancreatic fluid collections: a meta-analysis and trial sequential analysis.

Authors:  Rajesh Panwar; Preet Mohinder Singh
Journal:  Clin J Gastroenterol       Date:  2017-07-18

Review 4.  Efficacy and Safety of Lumen-Apposing Metal Stents in Management of Pancreatic Fluid Collections: Are They Better Than Plastic Stents? A Systematic Review and Meta-Analysis.

Authors:  Tariq Hammad; Muhammad Ali Khan; Yaseen Alastal; Wade Lee; Ali Nawras; Mohammad Kashif Ismail; Michel Kahaleh
Journal:  Dig Dis Sci       Date:  2017-12-27       Impact factor: 3.199

5.  Multivariate analysis of the factors affecting the prognosis of walled-off pancreatic necrosis after endoscopic ultrasound-guided drainage.

Authors:  Jintao Guo; Bowen Duan; Siyu Sun; Sheng Wang; Xiang Liu; Nan Ge; Wen Liu; Shupeng Wang; Jinlong Hu
Journal:  Surg Endosc       Date:  2019-06-12       Impact factor: 4.584

6.  Increased Incidence of Pseudoaneurysm Bleeding With Lumen-Apposing Metal Stents Compared to Double-Pigtail Plastic Stents in Patients With Peripancreatic Fluid Collections.

Authors:  Bryan Brimhall; Samuel Han; Philip D Tatman; Toshimasa J Clark; Sachin Wani; Brian Brauer; Steven Edmundowicz; Mihir S Wagh; Augustin Attwell; Hazem Hammad; Raj J Shah
Journal:  Clin Gastroenterol Hepatol       Date:  2018-02-21       Impact factor: 11.382

7.  International, multicenter retrospective trial comparing the efficacy and safety of bi-flanged versus lumen-apposing metal stents for endoscopic drainage of walled-off pancreatic necrosis.

Authors:  Ali Siddiqui; Mariam Naveed; Jahangeer Basha; Sundeep Lakhtakia; Jose Nieto; Janak Shah; Kenneth Binmoeller; Megan Murphy; Rupjyoti Talukdar; Mohan K Ramchandani; Zaheer Nabi; Rajesh Gupta; Thomas E Kowalski; David E Loren; Reem Z Sharaiha; Michel Kahaleh; Patrick Ten Eyck; Arish Noor; Tayebah Mumtaz; Rakesh Kalalala; Nageshwar D Reddy; Douglas G Adler
Journal:  Ann Gastroenterol       Date:  2021-01-04

8.  Complications of Long-Term Indwelling Transmural Double Pigtail Stent Placement for Symptomatic Peripancreatic Fluid Collections.

Authors:  Hiroshi Yamauchi; Tomohisa Iwai; Mitsuhiro Kida; Kosuke Okuwaki; Takahiro Kurosu; Masafumi Watanabe; Kai Adachi; Masayoshi Tadehara; Hiroshi Imaizumi; Wasaburo Koizumi
Journal:  Dig Dis Sci       Date:  2019-02-06       Impact factor: 3.487

9.  Metal versus plastic stents for drainage of pancreatic fluid collection: A meta-analysis.

Authors:  Seung Bae Yoon; In Seok Lee; Myung-Gyu Choi
Journal:  United European Gastroenterol J       Date:  2018-02-28       Impact factor: 4.623

10.  The Evolution of EUS-Guided Transluminal Drainage for the Treatment of Pancreatic Fluid Collections: A Comparison of Clinical and Cost Outcomes with Double-Pigtail Plastic Stents, Conventional Metal Stents and Lumen-Apposing Metal Stents.

Authors:  Vanessa Falk; Sana Kenshil; Simrat Sandha; Christopher Teshima; Pernilla D'Souza; Gurpal Sandha
Journal:  J Can Assoc Gastroenterol       Date:  2018-09-12
View more