Literature DB >> 25262964

Long-term results of aortic valve replacement with mechanical prosthesis or carpentier-edwards perimount bioprosthesis in Japanese patients according to age.

Takahiro Nishida1, Hiromichi Sonoda, Yasuhisa Oishi, Hideki Tatewaki, Yoshihisa Tanoue, Yuichi Shiokawa, Ryuji Tominaga.   

Abstract

BACKGROUND: The long-term results of aortic valve replacement (AVR; n=737) with bileaflet mechanical prosthesis (MP) or Carpentier-Edwards Perimount bioprostheses (BP) were evaluated in different age groups. METHODS AND 
RESULTS: Since 1981, a total of 737 prostheses (424 bileaflet MP vs. 313 BP) were implanted for AVR in 278 patients aged ≥70 years (79 MP vs. 199 BP), in 191 patients aged 60-69 years (128 MP vs. 63 BP) and in 268 patients aged <60 years (217 MP vs. 51 BP). Follow-up was completed for 6,523 patient-years in 98.5% of cases. Among the patients ≥70 years, both the actuarial survival rate (P=0.0434) and freedom from valve-related morbidity (P=0.0205) were better in the BP group than in the MP group without any difference in occurrence of structural valve deterioration in both groups. Among the patients aged 60-69, anticoagulant-related complications occurred less often in the BP group (P=0.0134) without any difference in long-term survival. Among the patients aged <60, long-term survival was significantly better in the MP group, whereas freedom from anticoagulant-related events did not differ.
CONCLUSIONS: The use of BP is suitable in patients aged ≥70 years, while the use of bileaflet MP is preferable in patients aged <60 years. Among patients aged 60-69 years, the use of BP is acceptable because of the lower incidence of anticoagulant-related events and the equivalent long-term survival.

Entities:  

Mesh:

Year:  2014        PMID: 25262964     DOI: 10.1253/circj.cj-14-0466

Source DB:  PubMed          Journal:  Circ J        ISSN: 1346-9843            Impact factor:   2.993


  8 in total

1.  Long-Term Outcome of Prosthetic Valve Replacement in Japanese Patients Aged 65 Years or Older: Are Guidelines for Prosthetic Valve Selection Based on Overseas Data Appropriate for Japanese Patients?

Authors:  Akira Sezai; Shunji Osaka; Hiroko Yaoita; Yusuke Ishii; Munehito Arimoto; Hiroaki Hata; Motomi Shiono
Journal:  Ann Thorac Cardiovasc Surg       Date:  2015-05-25       Impact factor: 1.520

Review 2.  Selection of prosthetic valve and evidence--need for the development of Japan's own guidelines.

Authors:  Akira Sezai; Motomi Shiono
Journal:  Ann Thorac Cardiovasc Surg       Date:  2015-06-09       Impact factor: 1.520

3.  Outcomes of surgical aortic valve replacement using Carpentier-Edwards PERIMOUNT bioprosthesis series in elderly patients with severe aortic valve stenosis: a retrospective cohort study.

Authors:  Naritomo Nishioka; Akira Yamada; Kosuke Ujihira; Yutaka Iba; Ryushi Maruyama; Eiichiro Hatta; Yoshihiko Kurimoto; Katsuhiko Nakanishi
Journal:  Gen Thorac Cardiovasc Surg       Date:  2016-08-04

4.  Choice of Aortic Valve Prosthesis in a Rapidly Aging and Long-Living Society.

Authors:  Yoshimasa Sakamoto; Michio Yoshitake; Yoko Matsumura; Hitomi Naruse; Ko Bando; Kazuhiro Hashimoto
Journal:  Ann Thorac Cardiovasc Surg       Date:  2016-09-12       Impact factor: 1.520

5.  Long-term results after treatment of the ascending aorta for bicuspid aortic valve patients.

Authors:  Sho Matsuyama; Takahiro Nishida; Tomoki Ushijima; Ryuji Tominaga
Journal:  Surg Today       Date:  2015-11-12       Impact factor: 2.549

6.  [Safety of biological valves for aortic valve replacement: A systematic review and meta-analysis].

Authors:  B Q Zeng; S Q Yu; Y Chen; W Zhai; B Liu; S Y Zhan; F Sun
Journal:  Beijing Da Xue Xue Bao Yi Xue Ban       Date:  2020-06-18

7.  Intermediate-term outcomes after aortic valve replacement with a novel RESILIATM tissue bioprosthesis.

Authors:  Krzysztof Bartus; Radoslaw Litwinowicz; Agata Bilewska; Maciej Stapor; Maciej Bochenek; Jacek Rozanski; Jerzy Sadowski; Grzegorz Filip; Boguslaw Kapelak; Mariusz Kusmierczyk
Journal:  J Thorac Dis       Date:  2019-07       Impact factor: 2.895

8.  Late clinical outcomes after mechanical aortic valve replacement for aortic stenosis: old versus new prostheses.

Authors:  Heemoon Lee; Kiick Sung; Wook Sung Kim; Dong Seop Jeong; Joong Hyun Ahn; Keumhee Chough Carriere; Pyo Won Park
Journal:  J Thorac Dis       Date:  2018-06       Impact factor: 2.895

  8 in total