Literature DB >> 25262876

Hemodynamic study of overlapping bare-metal stents intervention to aortic aneurysm.

Peng Zhang1, Anqiang Sun2, Fan Zhan1, Jingyuan Luan3, Xiaoyan Deng4.   

Abstract

To investigate the hemodynamic performance of overlapping bare-metal stents intervention treatment to thoracic aortic aneurysms (TAA), three simplified TAA models, representing, no stent, with a single stent and 2 overlapped stents deployed in the aneurismal sac, were studied and compared in terms of flow velocity, wall shear stress (WSS) and pressure distributions by means of computational fluid dynamics. The results showed that overlapping stents intervention induced a flow field of slow velocity near the aneurismal wall. Single stent deployment in the sac reduced the jet-like flow formed prior to the proximal neck of the aneurysm, which impinged on the internal wall of the aneurysm. This jet-like flow vanished completely in the overlapping double stents case. Overlapping stents intervention led to an evident decrease in WSS; meanwhile, the pressure acting on the wall of the aneurysm was reduced slightly and presented more uniform distribution. The results therefore indicated that overlapping stents intervention may effectively isolate the thoracic aortic aneurysm, protecting it from rupture. In conclusion, overlapping bare-metal stents may serve a purpose similar to that of the multilayer aneurysm repair system (MARS) manufactured by Cardiatis SA (Isnes, Belgium).
Copyright © 2014 Elsevier Ltd. All rights reserved.

Entities:  

Keywords:  Hemodynamics; Numerical simulation; Overlapping bare-metal stents; Thoracic aortic aneurysm

Mesh:

Substances:

Year:  2014        PMID: 25262876     DOI: 10.1016/j.jbiomech.2014.08.025

Source DB:  PubMed          Journal:  J Biomech        ISSN: 0021-9290            Impact factor:   2.712


  5 in total

1.  The hydrodynamic basis of the vacuum cleaner effect in continuous-flow PCNL instruments: an empiric approach and mathematical model.

Authors:  R Mager; C Balzereit; K Gust; T Hüsch; T Herrmann; U Nagele; A Haferkamp; D Schilling
Journal:  World J Urol       Date:  2015-09-10       Impact factor: 4.226

2.  Finite Element Analysis of the Implantation Process of Overlapping Stents.

Authors:  Jiang Xu; Jie Yang; Salman Sohrabi; Yihua Zhou; Yaling Liu
Journal:  J Med Device       Date:  2017-05-03       Impact factor: 0.582

3.  Hemodynamic Study of Flow Remodeling Stent Graft for the Treatment of Highly Angulated Abdominal Aortic Aneurysm.

Authors:  Siang Lin Yeow; Hwa Liang Leo
Journal:  Comput Math Methods Med       Date:  2016-05-09       Impact factor: 2.238

4.  Hemodynamics study of a multilayer stent for the treatment of aneurysms.

Authors:  Yan Xiong; Xuhong Wang; Wentao Jiang; Xiaobao Tian; Qingyuan Wang; Yubo Fan; Yu Chen
Journal:  Biomed Eng Online       Date:  2016-12-28       Impact factor: 2.819

5.  Stent graft coverage of dual-stent strategy in the management of abdominal aortic aneurysms.

Authors:  Yuan Ding; Li Zhongyou; Jiang Wentao; Zhang Yinci; Wang Zhenze; Chen Yu
Journal:  Sci Rep       Date:  2018-11-05       Impact factor: 4.379