PURPOSE: To test the validity and reliability of field critical power (CP). METHOD: Laboratory CP tests comprised three exhaustive trials at intensities of 80, 100 and 105 % maximal aerobic power and CP results were compared with those determined from the field. Experiment 1: cyclists performed three CP field tests which comprised maximal efforts of 12, 7 and 3 min with a 30 min recovery between efforts. Experiment 2: cyclists performed 3 × 3, 3 × 7 and 3 × 12 min individual maximal efforts in a randomised order in the field. Experiment 3: the highest 3, 7 and 12 min power outputs were extracted from field training and racing data. RESULTS: Standard error of the estimate of CP was 4.5, 5.8 and 5.2 % for experiments 1-3, respectively. Limits of agreement for CP were -26 to 29, 26 to 53 and -34 to 44 W for experiments 1-3, respectively. Mean coefficient of variation in field CP was 2.4, 6.5 and 3.5 % for experiments 1-3, respectively. Intraclass correlation coefficients of the three repeated trials for CP were 0.99, 0.96 and 0.99 for experiments 1-3, respectively. CONCLUSIONS: Results suggest field-testing using the different protocols from this research study, produce both valid and reliable CP values.
PURPOSE: To test the validity and reliability of field critical power (CP). METHOD: Laboratory CP tests comprised three exhaustive trials at intensities of 80, 100 and 105 % maximal aerobic power and CP results were compared with those determined from the field. Experiment 1: cyclists performed three CP field tests which comprised maximal efforts of 12, 7 and 3 min with a 30 min recovery between efforts. Experiment 2: cyclists performed 3 × 3, 3 × 7 and 3 × 12 min individual maximal efforts in a randomised order in the field. Experiment 3: the highest 3, 7 and 12 min power outputs were extracted from field training and racing data. RESULTS: Standard error of the estimate of CP was 4.5, 5.8 and 5.2 % for experiments 1-3, respectively. Limits of agreement for CP were -26 to 29, 26 to 53 and -34 to 44 W for experiments 1-3, respectively. Mean coefficient of variation in field CP was 2.4, 6.5 and 3.5 % for experiments 1-3, respectively. Intraclass correlation coefficients of the three repeated trials for CP were 0.99, 0.96 and 0.99 for experiments 1-3, respectively. CONCLUSIONS: Results suggest field-testing using the different protocols from this research study, produce both valid and reliable CP values.
Authors: Andy Galbraith; James Hopker; Stephen Lelliott; Louise Diddams; Louis Passfield Journal: Int J Sports Physiol Perform Date: 2014-03-11 Impact factor: 4.010
Authors: Andrew S Gardner; Shaun Stephens; David T Martin; Evan Lawton; Hamilton Lee; David Jenkins Journal: Med Sci Sports Exerc Date: 2004-07 Impact factor: 5.411
Authors: Michael J Puchowicz; Eliran Mizelman; Assaf Yogev; Michael S Koehle; Nathan E Townsend; David C Clarke Journal: Front Physiol Date: 2018-06-06 Impact factor: 4.566
Authors: Christoph Triska; Bettina Karsten; Bernd Heidegger; Bernhard Koller-Zeisler; Bernhard Prinz; Alfred Nimmerichter; Harald Tschan Journal: PLoS One Date: 2017-12-15 Impact factor: 3.240