Literature DB >> 25255170

Continuous bed motion on clinical scanner: design, data correction, and reconstruction.

V Y Panin1, A M Smith, J Hu, F Kehren, M E Casey.   

Abstract

With the addition of variable bed speed capabilities, continuous bed motion (CBM) becomes an acquisition generalization for axial sensitivity modeling and therefore a flexible tool in axial local image quality adjustment. In this paper, we describe the principles behind CBM mode planning and its influence on image reconstruction. The data correction method underwent the most changes compared to the commonly used step and shoot (S&S) mode. The CBM normalization array accommodates for activity decay, dead time correction, and the fact that various detector pairs acquire the same data for different durations. The normalization array is computed by simulating the movement of an object through the scanner, assisted by the monitoring of basic scanner acquisition parameters such as the singles rate. The sensitivity, which is the number of counts acquired per image plane, is an intrinsic part of normalization computing. Basic equations to estimate acquisition time at matched sensitivity between single speed CBM and S&S mode are presented. The CBM feature was implemented on a Siemens clinical scanner and initial studies of phantoms and patients are presented. The equivalence of single speed CBM and S&S image quality is demonstrated.

Entities:  

Mesh:

Year:  2014        PMID: 25255170     DOI: 10.1088/0031-9155/59/20/6153

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  6 in total

Review 1.  Towards enhanced PET quantification in clinical oncology.

Authors:  Habib Zaidi; Nicolas Karakatsanis
Journal:  Br J Radiol       Date:  2017-11-22       Impact factor: 3.039

2.  Comparison of Step-and-Shoot and Continuous-Bed-Motion PET Modes of Acquisition for Limited-View Organ Scans.

Authors:  Wendy Siman; S Cheenu Kappadath
Journal:  J Nucl Med Technol       Date:  2017-10-17

3.  A randomized, double-blind, crossover comparison of novel continuous bed motion versus traditional bed position whole-body PET/CT imaging.

Authors:  Imke Schatka; Desiree Weiberg; Stephanie Reichelt; Nicole Owsianski-Hille; Thorsten Derlin; Georg Berding; Frank M Bengel
Journal:  Eur J Nucl Med Mol Imaging       Date:  2015-11-06       Impact factor: 9.236

4.  Augmented Whole-Body Scanning via Magnifying PET.

Authors:  Jianyong Jiang; Suranjana Samanta; Ke Li; Stefan B Siegel; Robert A Mintzer; Sanghee Cho; Maurizio Conti; Matthias Schmand; Joseph O'Sullivan; Yuan-Chuan Tai
Journal:  IEEE Trans Med Imaging       Date:  2020-10-28       Impact factor: 10.048

5.  Impact of low injected activity on data driven respiratory gating for PET/CT imaging with continuous bed motion.

Authors:  Joseph G Meier; Radwan H Diab; Trevor M Connor; Osama R Mawlawi
Journal:  J Appl Clin Med Phys       Date:  2022-04-28       Impact factor: 2.243

6.  Benefit of Improved Performance with State-of-the Art Digital PET/CT for Lesion Detection in Oncology.

Authors:  Suleman Surti; Varsha Viswanath; Margaret E Daube-Witherspoon; Maurizio Conti; Michael E Casey; Joel S Karp
Journal:  J Nucl Med       Date:  2020-03-20       Impact factor: 11.082

  6 in total