Literature DB >> 25252042

Axillary vein technique for pacemaker and implantable defibrillator leads implantation: a safe and alternative approach?

Federico Migliore1, Antonio Curnis, Emanuele Bertaglia.   

Abstract

Different methods for venous access are used for permanent pacemaker or implantable cardioverter defibrillator (ICD), of which subclavian vein puncture technique is the most widely practised. Although this approach is relatively easy to learn, quick and offers high success rates, it may be associated with potential serious acute complications including pneumothorax, emopneumothorax, brachial plexus injury and longer-term complications such as lead fracture, loss of lead insulation and subclavian crush syndrome especially in young patients with ICD leads. Axillary vein approach seems to be a favourable technique not only for the prevention of acute complications but also to reduce lead failure including lead insulation and lead fracture prevention with a consequently better long-term lead survival compared with the classical subclavian approach. Although randomized studies are lacking, recent reports not only evaluated the safety and effectiveness of new fluoroscopic axillary venous puncture technique, but also compared it with the conventional intrathoracic subclavian venous puncture technique for the implantation of leads in permanent pacing. Various techniques of axillary vein puncture have been proposed ranging from a blind percutaneous puncture to the use of different tools such as contrast venography and ultrasound. In this article, we report a case of subclavian crush syndrome, the use of a modified Bellot's technique of axillary vein puncture that we currently use and the potential benefits of axillary vein puncture for pacemaker and ICD leads implantation compared with subclavian approach to avoid acute and long-term lead complications.

Entities:  

Mesh:

Year:  2016        PMID: 25252042     DOI: 10.2459/JCM.0000000000000154

Source DB:  PubMed          Journal:  J Cardiovasc Med (Hagerstown)        ISSN: 1558-2027            Impact factor:   2.160


  4 in total

1.  Axillary vein puncture using fluoroscopic landmarks: a safe and effective approach for implantable cardioverter defibrillator leads.

Authors:  Federico Migliore; Mariachiara Siciliano; Manuel De Lazzari; Sonia Ferretto; Chiara Dalla Valle; Alessandro Zorzi; Domenico Corrado; Sabino Iliceto; Emanuele Bertaglia
Journal:  J Interv Card Electrophysiol       Date:  2015-05-09       Impact factor: 1.900

2.  Efficacy of ultrasound-guided axillary/subclavian venous approaches for pacemaker and defibrillator lead implantation: a randomized study.

Authors:  Mattia Liccardo; Pasquale Nocerino; Salzano Gaia; Carmine Ciardiello
Journal:  J Interv Card Electrophysiol       Date:  2018-01-15       Impact factor: 1.900

3.  The axillary vein and its tributaries are not in the mirror image of the axillary artery and its branches.

Authors:  HyeYeon Lee; JongHo Bang; SooJung Kim; HeeJun Yang
Journal:  PLoS One       Date:  2019-01-10       Impact factor: 3.240

4.  Clinical outcomes and mortality in old and very old patients undergoing cardiac resynchronization therapy.

Authors:  Luiz Eduardo Montenegro Camanho; Eduardo Benchimol Saad; Charles Slater; Luiz Antonio Oliveira Inacio Junior; Gustavo Vignoli; Lucas Carvalho Dias; Pedro Pimenta de Mello Spineti; Ricardo Mourilhe-Rocha
Journal:  PLoS One       Date:  2019-12-02       Impact factor: 3.240

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.