Literature DB >> 25246375

Locking plate fixation provides superior fixation of humerus split type greater tuberosity fractures than tension bands and double row suture bridges.

Cinzia Gaudelli1, Jérémie Ménard2, Jennifer Mutch1, G-Yves Laflamme1, Yvan Petit3, Dominique M Rouleau4.   

Abstract

BACKGROUND: This paper aims to determine the strongest fixation method for split type greater tuberosity fractures of the proximal humerus by testing and comparing three fixation methods: a tension band with No. 2 wire suture, a double-row suture bridge with suture anchors, and a manually contoured calcaneal locking plate.
METHODS: Each method was tested on eight porcine humeri. A osteotomy of the greater tuberosity was performed 50° to the humeral shaft and then fixed according to one of three methods. The humeri were then placed in a testing apparatus and tension was applied along the supraspinatus tendon using a thermoelectric cooling clamp. The load required to produce 3mm and 5mm of displacement, as well as complete failure, was recorded using an axial load cell.
FINDINGS: The average load required to produce 3mm and 5mm of displacement was 658N and 1112N for the locking plate, 199N and 247N for the double row, and 75N and 105N for the tension band. The difference between the three groups was significant (P<0.01). The average load to failure of the locking plate (810N) was significantly stronger than double row (456N) and tension band (279N) (P<0.05). The stiffness of the locking plate (404N/mm) was significantly greater than double row (71N/mm) and tension band (33N/mm) (P<0.01).
INTERPRETATION: Locking plate fixation provides the strongest and stiffest biomechanical fixation for split type greater tuberosity fractures.
Copyright © 2014 Elsevier Ltd. All rights reserved.

Entities:  

Keywords:  Biomechanics; Double-row suture-bridge fixation; Greater tuberosity fracture; Locking plate; Tension band

Mesh:

Year:  2014        PMID: 25246375     DOI: 10.1016/j.clinbiomech.2014.08.013

Source DB:  PubMed          Journal:  Clin Biomech (Bristol, Avon)        ISSN: 0268-0033            Impact factor:   2.063


  9 in total

1.  [Osteosynthesis of displaced fractures of the greater tuberosity with the Bamberg plate].

Authors:  D Popp; V Schöffl; W Strecker
Journal:  Oper Orthop Traumatol       Date:  2016-08-02       Impact factor: 1.154

2.  Is Arthroscopic Technique Superior to Open Reduction Internal Fixation in the Treatment of Isolated Displaced Greater Tuberosity Fractures?

Authors:  Weixiong Liao; Hao Zhang; Zhongli Li; Ji Li
Journal:  Clin Orthop Relat Res       Date:  2016-01-04       Impact factor: 4.176

Review 3.  Surgical fixation of isolated greater tuberosity fractures of the humerus- systematic review and meta-analysis.

Authors:  Sachin Kumar; Arya Mishra; Hemant Singh; David Clark; Marius Espag; Amol Tambe
Journal:  J Clin Orthop Trauma       Date:  2021-10-27

4.  Open Reduction and Stable Internal Fixation Using a 3.5-mm Locking Hook Plate for Isolated Fractures of the Greater Tuberosity of the Humerus: A 2-Year Follow-up Study Using an Innovative Fixation Method.

Authors:  Woo-Yong Lee; Hyun-Dae Shin; Kyung-Cheon Kim; Soo-Min Cha; Yoo-Sun Jeon; Dong-Hwan Kim
Journal:  Clin Orthop Surg       Date:  2021-04-01

5.  The influence of fracture severity on postoperative outcome and quality of life after locking plate fixation of proximal humeral fractures.

Authors:  Simon Thelen; Jan P Grassmann; Madeleine Schneider; Carina Jaekel; Dana M Meier; Marcel Betsch; Mohssen Hakimi; Michael Wild
Journal:  GMS Interdiscip Plast Reconstr Surg DGPW       Date:  2022-05-23

6.  [Effectiveness of open reduction and locking compression hook plate in treatment of isolated humeral greater tuberosity fractures].

Authors:  Cheng Long; Zhou Xiang; Gang Zhong; Shiqiang Cen; Song Kuang; Changchun He; Tao Jiang; Fuguo Huang
Journal:  Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi       Date:  2019-04-15

7.  Biomechanical Analysis of the Fixation Strength of a Novel Plate for Greater Tuberosity Fractures.

Authors:  Aristotelis Kaisidis; Panagiotis G Pantos; Dimitrios Bochlos; Horst Lindner
Journal:  Open Orthop J       Date:  2018-06-29

8.  Augmented cerclage wire improves the fixation strength of a two-screw construct for humerus split type greater tuberosity fracture: a biomechanical study.

Authors:  Chao-Jui Chang; Wei-Ren Su; Kai-Lan Hsu; Chih-Kai Hong; Fa-Chuan Kuan; Chih-Hsun Chang; Cheng-Li Lin
Journal:  BMC Musculoskelet Disord       Date:  2021-04-12       Impact factor: 2.362

9.  A new biomechanical classification system for split fractures of the humeral greater tuberosity: guidelines for surgical treatment.

Authors:  Gang Liu; Xiaoguang Guo; Qian Zhao; Bo Qin; Junjie Lu; Dingsu Bao; Shijie Fu
Journal:  J Orthop Surg Res       Date:  2021-11-24       Impact factor: 2.359

  9 in total