Literature DB >> 2523971

Measurement of the force necessary for laparoscopic trocar entry.

S L Corson1, F R Batzer, B Gocial, G Maislin.   

Abstract

A study was designed to measure the force necessary for trocar insertion before laparoscopy. A strain gauge was used to measure the force used with a reusable, pyramid-tipped trocar system sharpened at regular intervals and a disposable trocar system also with a pyramidal point and of equal diameter (10 mm). Variables studied for both groups, 50 patients each, included the type of incision made at the umbilicus; the opening and closing laparoscopic gas source pressure; the volume of gas delivered to create the pneumoperitoneum; the age, weight and height of the patient; and whether the laparoscopy was the first or a repeat. The variables were matched for both groups. The disposable device required half the force for entry required with the reusable device. Since many gynecologists are now women and thus may have less upper body strength than men do, this finding could be important for them. Further, the disposable trocar affords an operator of any size and strength greater control over the potentially dangerous trocar insertion into the abdomen since less force is required.

Entities:  

Mesh:

Year:  1989        PMID: 2523971

Source DB:  PubMed          Journal:  J Reprod Med        ISSN: 0024-7758            Impact factor:   0.142


  5 in total

1.  A cost comparison of disposable vs reusable instruments in laparoscopic cholecystectomy.

Authors:  L Demoulin; K Kesteloot; F Penninckx
Journal:  Surg Endosc       Date:  1996-05       Impact factor: 4.584

2.  Specialized endoscopic equipment.

Authors:  J M Sackier
Journal:  Surg Endosc       Date:  1993 Mar-Apr       Impact factor: 4.584

3.  Reusable instruments are more cost-effective than disposable instruments for laparoscopic cholecystectomy.

Authors:  K N Apelgren; M L Blank; C A Slomski; N S Hadjis
Journal:  Surg Endosc       Date:  1994-01       Impact factor: 4.584

4.  A multicentric prospective study evaluating the safety and efficacy of Kii® Fios® First Entry Trocar in laparoscopic bariatric surgery.

Authors:  Marcelo Loureiro; Mohamad Ramadan; El Mehdi Skalli; Pierre Blanc; Jean Michel Fabre; David Nocca
Journal:  Surg Endosc       Date:  2017-04-07       Impact factor: 4.584

5.  Method for safe Verres needle entry at the umbilicus, with modification for first trocar entry to reduce the complication rate of first entry.

Authors:  Tehemton Erach Udwadia
Journal:  J Minim Access Surg       Date:  2021 Jul-Sep       Impact factor: 1.407