Literature DB >> 25239596

Effect of 25(OH) vitamin D reference method procedure (RMP) alignment on clinical measurements obtained with the IDS-iSYS chemiluminescent-based automated analyzer.

Christine A Simpson1, Anna Maria Cusano2, Jessica Bihuniak3, Joanne Walker4, Karl L Insogna5.   

Abstract

The Vitamin D Standardization Program (VDSP) has identified ID-LC/MS/MS as the reference method procedure (RMP) for 25(OH) vitamin D and NIST Standard SRM2972 as the standard reference material (SRM). As manufacturers align their products to the RMP and NIST standard, a concern is that results obtained in aligned assays will be divergent from those obtained with pre-alignment assays. The Immunodiagnostic Systems Ltd., chemiluminescent, 25(OH) vitamin D iSYS platform assay, was recently harmonized to the RMP. To determine the impact of standardization on results obtained with iSYS reagents, 119 single donor serum samples from eight different disease categories were analyzed in four non-standardized and two standardized iSYS assays. There were strong correlations between the four non-standardized and two standardized assays with Spearman's rank r values between 0.975 and 0.961 and four of the eight r values were >0.97. R(2) values for the eight best-fit linear regression equations ranging between 0.947 and 0.916. None of the slopes were found to be significantly different from one another. Bland-Altman plots showed that the bias was comparable when each of the four non-standardized assays was compared to either of the standardized assays. When the data were segregated in values between 6 and 49ng/mL (15-122nmol/L) or between 50 and 100ng/mL (125-250nmol/L) significant associations remained between results obtained with non-standardized and standardized calibrators regardless of the absolute value. When five recent DEQAS unknowns were analyzed in one non-standardized and one standardized assay the mean percent difference from the NIST target in values obtained using standardized vs. non-standardized calibrators were not significantly different. Finally, strong and statistically significant associations between the results were obtained using non-standardized and standardized assays for six of eight clinical conditions. The only exceptions were hypocalcemia and breast cancer, which likely reflect the small sample sizes for each of these diseases. These initial data provide confidence that the move to a NIST standardized assay will have little impact on results obtained with the iSYS platform. This article is part of a Special Issue entitled '17th Vitamin D Workshop'.
Copyright © 2014 Elsevier Ltd. All rights reserved.

Entities:  

Keywords:  25-hydroxy vitamin D; Harmonization; Standardization

Mesh:

Substances:

Year:  2014        PMID: 25239596     DOI: 10.1016/j.jsbmb.2014.09.013

Source DB:  PubMed          Journal:  J Steroid Biochem Mol Biol        ISSN: 0960-0760            Impact factor:   4.292


  5 in total

1.  Three-Month Randomized Clinical Trial of Nasal Calcitonin in Adults with X-linked Hypophosphatemia.

Authors:  Rebecca Sullivan; Alice Abraham; Christine Simpson; Elizabeth Olear; Thomas Carpenter; Yanhong Deng; Chuqing Chen; Karl L Insogna
Journal:  Calcif Tissue Int       Date:  2018-01-30       Impact factor: 4.333

2.  25OHD analogues and vacuum blood collection tubes dramatically affect the accuracy of automated immunoassays.

Authors:  Songlin Yu; Xinqi Cheng; Huiling Fang; Ruiping Zhang; Jianhua Han; Xuzhen Qin; Qian Cheng; Wei Su; Li'an Hou; Liangyu Xia; Ling Qiu
Journal:  Sci Rep       Date:  2015-09-30       Impact factor: 4.379

3.  Evaluation of new Beckman Coulter 25(OH) Vitamin D assay and potential improvement of clinical interpretation.

Authors:  Özlem Ç Madenci; Asuman Orçun; Zeynep Yildiz; Rana Sirmali; Nazan Tunçbilek; Nihal Yücel; Yusuf Temel; Aycan Bölük
Journal:  Biochem Med (Zagreb)       Date:  2017-06-15       Impact factor: 2.313

4.  Vitamin D deficiency is highly prevalent in malnourished inpatients and associated with higher mortality: A prospective cohort study.

Authors:  Meret Merker; Aline Amsler; Renata Pereira; Rebekka Bolliger; Pascal Tribolet; Nina Braun; Claus Hoess; Vojtech Pavlicek; Stefan Bilz; Sarah Sigrist; Michael Brändle; Christoph Henzen; Robert Thomann; Jonas Rutishauser; Drahomir Aujesky; Nicolas Rodondi; Jaques Donzé; Zeno Stanga; Beat Mueller; Philipp Schuetz
Journal:  Medicine (Baltimore)       Date:  2019-11       Impact factor: 1.889

5.  Serum Vitamin D Levels Explored in the Latvian Cohort of Patients with Basal Cell Carcinoma Linked to the Sonic Hedgehog and Vitamin D Binding Protein Cutaneous Tissue Indices.

Authors:  Jeļena Moisejenko-Goluboviča; Valērija Groma; Šimons Svirskis; Anna Ivanova
Journal:  Nutrients       Date:  2022-08-16       Impact factor: 6.706

  5 in total