Literature DB >> 25236714

Frequency filtering based analysis on the cardiac induced lung tumor motion and its impact on the radiotherapy management.

Ting Chen1, Songbing Qin2, Xiaoting Xu2, Salma K Jabbour3, Bruce G Haffty3, Ning J Yue3.   

Abstract

PURPOSE/
OBJECTIVES: Lung tumor motion may be impacted by heartbeat in addition to respiration. This study seeks to quantitatively analyze heart-motion-induced tumor motion and to evaluate its impact on lung cancer radiotherapy. METHODS/MATERIALS: Fluoroscopy images were acquired for 30 lung cancer patients. Tumor, diaphragm, and heart were delineated on selected fluoroscopy frames, and their motion was tracked and converted into temporal signals based on deformable registration propagation. The clinical relevance of heart impact was evaluated using the dose volumetric histogram of the redefined target volumes.
RESULTS: Correlation was found between tumor and cardiac motion for 23 patients. The heart-induced motion amplitude ranged from 0.2 to 2.6 mm. The ratio between heart-induced tumor motion and the tumor motion was inversely proportional to the amplitude of overall tumor motion. When the heart motion impact was integrated, there was an average 9% increase in internal target volumes for 17 patients. Dose coverage decrease was observed on redefined planning target volume in simulated SBRT plans.
CONCLUSIONS: The tumor motion of thoracic cancer patients is influenced by both heart and respiratory motion. The cardiac impact is relatively more significant for tumor with less motion, which may lead to clinically significant uncertainty in radiotherapy for some patients.
Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.

Entities:  

Keywords:  Cardiac motion; Deformable image registration; Fluoroscopy; Frequency analysis; Lung tumor; Respiratory motion

Mesh:

Year:  2014        PMID: 25236714     DOI: 10.1016/j.radonc.2014.08.007

Source DB:  PubMed          Journal:  Radiother Oncol        ISSN: 0167-8140            Impact factor:   6.280


  3 in total

1.  Characterizing spatiotemporal information loss in sparse-sampling-based dynamic MRI for monitoring respiration-induced tumor motion in radiotherapy.

Authors:  Tatsuya J Arai; Joris Nofiele; Ananth J Madhuranthakam; Qing Yuan; Ivan Pedrosa; Rajiv Chopra; Amit Sawant
Journal:  Med Phys       Date:  2016-06       Impact factor: 4.071

2.  Motion correction for routine X-ray lung CT imaging.

Authors:  Doil Kim; Jiyoung Choi; Duhgoon Lee; Hyesun Kim; Jiyoung Jung; Minkook Cho; Kyoung-Yong Lee
Journal:  Sci Rep       Date:  2021-02-12       Impact factor: 4.379

3.  Real-time measurement of ICD lead motion during stereotactic body radiotherapy of ventricular tachycardia.

Authors:  Lukas Knybel; Jakub Cvek; Radek Neuwirth; Otakar Jiravsky; Jan Hecko; Marek Penhaker; Marek Sramko; Josef Kautzner
Journal:  Rep Pract Oncol Radiother       Date:  2021-02-25
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.