Sunil J Ghelani1, Andrew C Glatz2, Sthuthi David1, Ryan Leahy3, Russel Hirsch4, Laurie B Armsby5, Sara M Trucco6, Ralf J Holzer7, Lisa Bergersen8. 1. Department of Cardiology, Boston Children's Hospital, Boston, Massachusetts. 2. Division of Cardiology, Children's Hospital of Philadelphia, Philadelphia, Pennsylvania. 3. Division of Cardiology, University of Louisville, Louisville, Kentucky. 4. Cincinnati Children's Medical Center, Cincinnati, Ohio. 5. Oregon Health and Science University, Portland, Oregon. 6. Children's Hospital of Pittsburgh, Pittsburgh, Pennsylvania. 7. The Heart Center, Nationwide Children's Hospital, Columbus, Ohio. 8. Department of Cardiology, Boston Children's Hospital, Boston, Massachusetts. Electronic address: lisa.bergersen@cardio.chboston.org.
Abstract
OBJECTIVES: The aim of this study was to define age-stratified, procedure-specific benchmark radiation dose levels during interventional catheterization for congenital heart disease. BACKGROUND: There is a paucity of published literature with regard to radiation dose levels during catheterization for congenital heart disease. Obtaining benchmark radiation data is essential for assessing the impact of quality improvement initiatives for radiation safety. METHODS: Data were obtained retrospectively from 7 laboratories participating in the Congenital Cardiac Catheterization Project on Outcomes collaborative. Total air kerma, dose area product, and total fluoroscopy time were obtained for the following procedures: 1) patent ductus arteriosus closure; 2) atrial septal defect closure; 3) pulmonary valvuloplasty; 4) aortic valvuloplasty; 5) treatment of coarctation of aorta; and 6) transcatheter pulmonary valve placement. RESULTS: Between January 2009 and July 2013, 2,713 cases were identified. Radiation dose benchmarks are presented including median, 75th percentile, and 95th percentile. Radiation doses varied widely between age groups and procedure types. Radiation exposure was lowest in patent ductus arteriosus closure and highest in transcatheter pulmonary valve placement. Total fluoroscopy time was a poor marker of radiation exposure and did not correlate well with total air kerma and dose area product. CONCLUSIONS: This study presents age-stratified radiation dose values for 6 common congenital heart interventional catheterization procedures. Fluoroscopy time alone is not an adequate measure for monitoring radiation exposure. These values will be used as baseline for measuring the effectiveness of future quality improvement activities by the Congenital Cardiac Catheterization Project on Outcomes collaborative.
OBJECTIVES: The aim of this study was to define age-stratified, procedure-specific benchmark radiation dose levels during interventional catheterization for congenital heart disease. BACKGROUND: There is a paucity of published literature with regard to radiation dose levels during catheterization for congenital heart disease. Obtaining benchmark radiation data is essential for assessing the impact of quality improvement initiatives for radiation safety. METHODS: Data were obtained retrospectively from 7 laboratories participating in the Congenital Cardiac Catheterization Project on Outcomes collaborative. Total air kerma, dose area product, and total fluoroscopy time were obtained for the following procedures: 1) patent ductus arteriosus closure; 2) atrial septal defect closure; 3) pulmonary valvuloplasty; 4) aortic valvuloplasty; 5) treatment of coarctation of aorta; and 6) transcatheter pulmonary valve placement. RESULTS: Between January 2009 and July 2013, 2,713 cases were identified. Radiation dose benchmarks are presented including median, 75th percentile, and 95th percentile. Radiation doses varied widely between age groups and procedure types. Radiation exposure was lowest in patent ductus arteriosus closure and highest in transcatheter pulmonary valve placement. Total fluoroscopy time was a poor marker of radiation exposure and did not correlate well with total air kerma and dose area product. CONCLUSIONS: This study presents age-stratified radiation dose values for 6 common congenital heart interventional catheterization procedures. Fluoroscopy time alone is not an adequate measure for monitoring radiation exposure. These values will be used as baseline for measuring the effectiveness of future quality improvement activities by the Congenital Cardiac Catheterization Project on Outcomes collaborative.
Authors: Brian P Quinn; Aimee K Armstrong; Holly D Bauser-Heaton; Ryan Callahan; Howaida G El-Said; Susan R Foerster; Bryan H Goldstein; Andrea S Goodman; Todd M Gudausky; Jacqueline N Kreutzer; Ryan A Leahy; Christopher J Petit; Toby A Rockefeller; Shabana Shahanavaz; Sara M Trucco; Lisa Bergersen Journal: Pediatr Cardiol Date: 2018-11-30 Impact factor: 1.655
Authors: Priscila C Cevallos; Molly J Rose; Laurie B Armsby; Aimee K Armstrong; Howaida El-Said; Susan R Foerster; Andrew C Glatz; Bryan H Goldstein; Michael R Hainstock; Jacqueline Kreutzer; Larry A Latson; Ryan A Leahy; Christopher J Petit; Alejandro Torres; Shabana Shahanavaz; Jeffrey D Zampi; Lisa Bergersen Journal: Pediatr Cardiol Date: 2016-08-08 Impact factor: 1.655
Authors: Matthew S Lazarus; Benjamin H Taragin; William Malouf; Terry L Levin; Eduardo Nororis; Alan H Schoenfeld; Amichai J Erdfarb Journal: Pediatr Radiol Date: 2019-01-10
Authors: Bradley C Clark; Kohei Sumihara; Robert McCarter; Charles I Berul; Jeffrey P Moak Journal: J Interv Card Electrophysiol Date: 2016-01-15 Impact factor: 1.900
Authors: Kevin D Hill; Chu Wang; Andrew J Einstein; Natalie Januzis; Giao Nguyen; Jennifer S Li; Gregory A Fleming; Terry K Yoshizumi Journal: Catheter Cardiovasc Interv Date: 2016-06-17 Impact factor: 2.692