Literature DB >> 25233164

The femoral neck safe zone: a radiographic simulation study to prevent cortical perforation with multiple screw insertion.

Ying Qi Zhang1, Shi Min Chang, Yi Gang Huang, Xin Wang.   

Abstract

OBJECTIVES: To calculate the probability of iatrogenic perforation when screws seem to be safe on radiographs. A risk zone (RZ) gradient is mapped to help surgeons determine the suitable screw positions.
METHODS: Using computed tomography data and image-processing software, 24 proximal femurs were reconstructed. The anteroposterior, lateral, and axial views were then simulated, and the safe zone and RZ were identified and calculated on the axial graphs. Each original axial graph was zoomed and compiled to match a calculated average image, and a gradient figure of the RZs was visualized.
RESULTS: All 24 femoral necks had cortical perforation RZs. The average risk percentage was 23.7%. The individual risk per quadrant was as follows: anterosuperior 2.5%, posteroinferior 3.8%, posterosuperior 6.7%, and anteroinferior 10.7%. Four safe and cortex-touching zones and a safe region were identified in femoral neck for 6.5-mm screws.
CONCLUSIONS: Surgeons should be wary of screws that appear close to the cortex on both radiographs, especially in the posterosuperior and anteroinferior quadrants, because such screws probably perforate the cortex. To minimize iatrogenic perforation, screw position should be assessed using a gradient figure of the RZs.

Mesh:

Year:  2015        PMID: 25233164     DOI: 10.1097/BOT.0000000000000239

Source DB:  PubMed          Journal:  J Orthop Trauma        ISSN: 0890-5339            Impact factor:   2.512


  7 in total

1.  Higher stability and more predictive fixation with the Femoral Neck System versus Hansson Pins in femoral neck fractures Pauwels II.

Authors:  Clemens Schopper; Ivan Zderic; Johanna Menze; David Müller; Mirko Rocci; Matthias Knobe; Etsuo Shoda; Geoff Richards; Boyko Gueorguiev; Karl Stoffel
Journal:  J Orthop Translat       Date:  2020-07-22       Impact factor: 5.191

2.  A radiographic simulation study of fixed superior pubic ramus fractures with retrograde screw insertion.

Authors:  Qi Quan; Lei Hong; Biao Chang; Ruo Xi Liu; Ying Qi Zhang; Qing Zhao; Shi Bi Lu
Journal:  J Orthop       Date:  2016-07-14

3.  Risk of bony violation with standard triple screw configurations for fixation of femoral neck fractures: A preliminary computed tomography based analysis.

Authors:  Vivek Trikha; Arvind Kumar; Samarth Mittal; Jigyasa Passey; Dushyant Chouhan; Siddharth Dubey
Journal:  J Clin Orthop Trauma       Date:  2020-05-05

4.  The Scaphoid Safe Zone: A Radiographic Simulation Study to Prevent Cortical Perforation Arising from Different Views.

Authors:  Qi Quan; Lei Hong; Biao Chang; Ruoxi Liu; Yun Zhu; Jiang Peng; Qing Zhao; Shibi Lu
Journal:  PLoS One       Date:  2017-01-23       Impact factor: 3.240

5.  The application of the 150° oblique tangential fluoroscopic view to detect the posterosuperior femoral neck screw in-out-in intraoperatively.

Authors:  Jian Zhang; Xin Tang
Journal:  Sci Rep       Date:  2022-07-27       Impact factor: 4.996

6.  A Novel 3D-Printed Device for Precise Percutaneous Placement of Cannulated Compression Screws in Human Femoral Neck Fractures.

Authors:  Cheng Long; Jin-Hai Liu; Xiang-Ping Chai; Xiang-Feng Liu; Zhi-Xi Duan
Journal:  Biomed Res Int       Date:  2021-06-10       Impact factor: 3.411

7.  Introduction of a guide based on a femoral neck section for fixation with multiple screws: a cadaveric study.

Authors:  Qiuliang Zhu; Bin Xu; Jinzhu Lv; Maohua Yan
Journal:  BMC Musculoskelet Disord       Date:  2018-04-04       Impact factor: 2.362