Literature DB >> 25231682

Transsacral screw safe zone size by sacral segmentation variations.

John J Lee1, Samuel L Rosenbaum, Alex Martusiewicz, Sven A Holcombe, Stewart C Wang, James A Goulet.   

Abstract

Variations in sacral segmentation may preclude safe placement of transsacral screws for posterior pelvis fixation. We developed a novel automated 3D technique to determine the safe zone size for transsacral screws in the upper two sacral segments in 526 adult pelvis computed tomography scans. Safe zone sizes were then compared by gender and sacral segmentation variations (number of neuroforamen and the presence/absence of lumbosacral transitional vertebrae, ± LSTV). Ten millimeters was used as the safety threshold for a large screw. 3 (0.6%), 366 (70%), and 157 (30%) sacra had 3, 4, or 5 neuroforamen, respectively. Eighty-eight (17%) were +LSTV. Safe zone size depended on gender, number of neuroforamen in -LSTV sacra and presence of LSTV (p < 0.001) but not on the uni- or bilateral nature of the LSTV. 17% of -LSTV sacra were below the safety threshold in S1, 27% in S2, whereas 3% of +LSTV sacra were below in S1, 74% in S2. Of -LSTV sacra that cannot take an S1 screw safely, 77% can do so in S2, leaving only 4% of sacra that cannot accommodate a screw safely in either upper segment. The results demonstrate a predictable pattern of safe zone size based on gender and sacral segmentation variations.
© 2014 Orthopaedic Research Society. Published by Wiley Periodicals, Inc.

Keywords:  lumbosacral transitional vertebrae; sacral dysmorphism; sacral safe zone; sacral segmentation; transsacral screw

Mesh:

Year:  2014        PMID: 25231682     DOI: 10.1002/jor.22739

Source DB:  PubMed          Journal:  J Orthop Res        ISSN: 0736-0266            Impact factor:   3.494


  12 in total

1.  Implications of structural variations in the human sacrum: why is an anatomical classification crucial?

Authors:  Niladri Kumar Mahato
Journal:  Surg Radiol Anat       Date:  2016-03-24       Impact factor: 1.246

2.  Transsacral Osseous Corridor Anatomy Is More Amenable To Screw Insertion In Males: A Biomorphometric Analysis of 280 Pelves.

Authors:  Florian Gras; Heiko Gottschling; Manuel Schröder; Ivan Marintschev; Gunther O Hofmann; Rainer Burgkart
Journal:  Clin Orthop Relat Res       Date:  2016-07-08       Impact factor: 4.176

3.  Computational simulation study on ilio-sacral screw fixations for pelvic ring injuries and implications in Asian sacrum.

Authors:  Chang-Soo Chon; Jin-Hoon Jeong; Bokku Kang; Han Sung Kim; Gu-Hee Jung
Journal:  Eur J Orthop Surg Traumatol       Date:  2017-10-13

Review 4.  Sacral fractures: classification and management.

Authors:  Nicholas M Beckmann; Naga R Chinapuvvula
Journal:  Emerg Radiol       Date:  2017-06-27

5.  Accuracy of navigated and conventional iliosacral screw placement in B- and C-type pelvic ring fractures.

Authors:  Josephine Berger-Groch; Marie Lueers; Johannes Maria Rueger; Wolfgang Lehmann; Darius Thiesen; Jan Philipp Kolb; Maximilian Johannes Hartel; Lars Gerhard Grossterlinden
Journal:  Eur J Trauma Emerg Surg       Date:  2018-07-20       Impact factor: 3.693

6.  Corridor-diameter-dependent angular tolerance for safe transiliosacral screw placement: an anatomic study of 433 pelves.

Authors:  D Alex McLaren; Gennadiy A Busel; Harsh R Parikh; Arthur Only; Jason Patterson; Brandon T Gaston; Ryan McLemore; Brian Cunningham
Journal:  Eur J Orthop Surg Traumatol       Date:  2021-03-01

7.  Re-examining the Spectrum of Lumbosacral Transitional Dysmorphisms: Quantifying Joint Asymmetries and Evaluating the Anatomy of Screw Fixation Corridors.

Authors:  Niladri Kumar Mahato
Journal:  Neurospine       Date:  2019-07-11

8.  Feasibility of iliosacral screw placement in patients with upper sacral dysplasia.

Authors:  Christoph J Laux; Lizzy Weigelt; Georg Osterhoff; Ksenija Slankamenac; Clément M L Werner
Journal:  J Orthop Surg Res       Date:  2019-12-09       Impact factor: 2.359

9.  A useful intraoperative technique for transiliac-transsacral screws: a point-to-point coaxial guide apparatus.

Authors:  Ze-Hang Zheng; Fei Xu; Zheng-Qiang Luo; Ye Ren; Tao Fu; Han-Qing Xu; Bin-Bin Liu
Journal:  J Orthop Surg Res       Date:  2021-01-28       Impact factor: 2.359

10.  Development of generic Asian pelvic bone models using CT-based 3D statistical modelling.

Authors:  Marc-Daniel Ahrend; Hansrudi Noser; Rukmanikanthan Shanmugam; Felix Burr; Lukas Kamer; Tunku Kamarul; Heinz Hügli; Andreas Nagy; Robert Geoff Richards; Boyko Gueorguiev-Rüegg
Journal:  J Orthop Translat       Date:  2019-11-04       Impact factor: 5.191

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.