Literature DB >> 25230185

Simultaneous screening of targeted and non-targeted contaminants using an LC-QTOF-MS system and automated MS/MS library searching.

S Herrera-Lopez1, M D Hernando, E García-Calvo, A R Fernández-Alba, M M Ulaszewska.   

Abstract

Simultaneous high-resolution full-scan and tandem mass spectrometry (MS/MS) analysis using time of flight mass spectrometry brings an answer for increasing demand of retrospective and non-targeted data analysis. Such analysis combined with spectral library searching is a promising tool for targeted and untargeted screening of small molecules. Despite considerable extension of the panel of compounds of tandem mass spectral libraries, the heterogeneity of spectral data poses a major challenge against the effective usage of spectral libraries. Performance evaluation of available LC-MS/MS libraries will significantly increase credibility in the search results. The present work was aimed to evaluate fluctuation of MS/MS pattern, in the peak intensities distribution together with mass accuracy measurements, and in consequence, performance compliant with ion ratio and mass error criteria as principles in identification processes for targeted and untargeted contaminants at trace levels. Matrix effect and ultra-trace levels of concentration (from 50 ng l(-1) to 1000 ng l(-1) were evaluated as potential source of inaccuracy in the performance of spectral matching. Matrix-matched samples and real samples were screened for proof of applicability. By manual review of data and application of ion ratio and ppm error criteria, false negatives were obtained; this number diminished when in-house library was used, while with on-line MS/MS databases 100% of positive samples were found. In our experience, intensity of peaks across spectra was highly correlated to the concentration effect and matrix complexity. In turn, analysis of spectra acquired at trace concentrations and in different matrices results in better performance in providing correct and reliable identification.
Copyright © 2014 John Wiley & Sons, Ltd.

Entities:  

Keywords:  LC-MS/MS library searching; matrix effect; relative intensity of product ions; screening of targets and non-targets; trace analysis

Mesh:

Substances:

Year:  2014        PMID: 25230185     DOI: 10.1002/jms.3428

Source DB:  PubMed          Journal:  J Mass Spectrom        ISSN: 1076-5174            Impact factor:   1.982


  3 in total

1.  Optimization of the Data Treatment Steps of a Non-targeted LC-MS-Based Workflow for the Identification of Trace Chemical Residues in Honey.

Authors:  Annie von Eyken; Stéphane Bayen
Journal:  J Am Soc Mass Spectrom       Date:  2019-03-14       Impact factor: 3.109

Review 2.  Identification of small molecules using accurate mass MS/MS search.

Authors:  Tobias Kind; Hiroshi Tsugawa; Tomas Cajka; Yan Ma; Zijuan Lai; Sajjan S Mehta; Gert Wohlgemuth; Dinesh Kumar Barupal; Megan R Showalter; Masanori Arita; Oliver Fiehn
Journal:  Mass Spectrom Rev       Date:  2017-04-24       Impact factor: 10.946

3.  An Automated Methodology for Non-targeted Compositional Analysis of Small Molecules in High Complexity Environmental Matrices Using Coupled Ultra Performance Liquid Chromatography Orbitrap Mass Spectrometry.

Authors:  Kelly L Pereira; Martyn W Ward; John L Wilkinson; Jonathan Brett Sallach; Daniel J Bryant; William J Dixon; Jacqueline F Hamilton; Alastair C Lewis
Journal:  Environ Sci Technol       Date:  2021-05-18       Impact factor: 9.028

  3 in total