Dynamic fatigue performance of implant-abutment assemblies with different tightening torque values.

Dandan Xia1, Hong Lin1, Shenpo Yuan1, Wei Bai1, Gang Zheng1.   

Abstract

Implant-abutment assemblies are usually subject to long-term cyclic loading. To evaluate the dynamic fatigue performance of implant-abutment assemblies with different tightening torque values, thirty implant-abutment assemblies (Zimmer Dental, Carlsbad, CA, USA) were randomly assigned to three tightening groups (24 Ncm; 30 Ncm; 36 Ncm), each consisted of 10 implants. Five specimens from each group were unscrewed, and their reverse torque values recorded. The remaining specimens were subjected to a load between 30 N~300 N at a loading frequency of 15 Hz for 5 × 10(6) cycles. After fatigue tests, residual reverse torque values were recorded if available. In the 24 Ncm tightening group, all the implants fractured at the first outer thread of the implant after fatigue loading, with fatigue crack propagation at the fractured surface showed by SEM observation. For the 30 Ncm and 36 Ncm tightening groups, a statistical significant difference (p<0.05) between the unloaded and loaded groups was revealed. Compared with the unloaded specimens, the specimens went through fatigue loading had decreased reverse torque values. It was demonstrated that insufficient torque will lead to poor fatigue performance of dental implant-abutment assemblies and abutment screws should be tightened to the torque recommended by the manufacturer. It was also concluded that fatigue loading would lead to preload loss.

Entities:  

Keywords:  Dental implants; fatigue testing; preload; reverse torque value

Mesh:

Year:  2014        PMID: 25226912     DOI: 10.3233/BME-141025

Source DB:  PubMed          Journal:  Biomed Mater Eng        ISSN: 0959-2989            Impact factor:   1.300


  8 in total

Review 1.  Preload loss of abutment screws after dynamic fatigue in single implant-supported restorations. A systematic review.

Authors:  Beatriz Pardal-Peláez; Javier Montero
Journal:  J Clin Exp Dent       Date:  2017-11-01

2.  In Vitro Evaluation of Manual Torque Values Applied to Implant-Abutment Complex by Different Clinicians and Abutment Screw Loosening.

Authors:  Onur Dincer Kose; Burcin Karataslı; Sabit Demircan; Taha Emre Kose; Erhan Cene; Serhan Aydın Aya; Mehmet Ali Erdem; Abdulkadir Burak Cankaya
Journal:  Biomed Res Int       Date:  2017-04-03       Impact factor: 3.411

Review 3.  Systematic analysis of factors that cause loss of preload in dental implants.

Authors:  S Nithyapriya; A S Ramesh; A Kirubakaran; Jeevitha Mani; J Raghunathan
Journal:  J Indian Prosthodont Soc       Date:  2018 Jul-Sep

4.  Influence of Implant Connection, Abutment Design and Screw Insertion Torque on Implant-Abutment Misfit.

Authors:  Jorge Vélez; Jesús Peláez; Carlos López-Suárez; Rubén Agustín-Panadero; Celia Tobar; María J Suárez
Journal:  J Clin Med       Date:  2020-07-24       Impact factor: 4.241

Review 5.  Review of the Mechanical Behavior of Different Implant-Abutment Connections.

Authors:  Ana Sofia Vinhas; Carlos Aroso; Filomena Salazar; Paula López-Jarana; José Vicente Ríos-Santos; Mariano Herrero-Climent
Journal:  Int J Environ Res Public Health       Date:  2020-11-23       Impact factor: 3.390

Review 6.  Implant Bio-mechanics for Successful Implant Therapy: A Systematic Review.

Authors:  Khaled Mosfer Alzahrani
Journal:  J Int Soc Prev Community Dent       Date:  2020-11-24

7.  Implant-Abutment Misfit after Cyclic Loading: An In Vitro Experimental Study.

Authors:  John Eversong Lucena de Vasconcelos; Jefferson David Melo de Matos; Daher Antonio Queiroz; Guilherme da Rocha Scalzer Lopes; Bruna Caroline Gonçalves Vasconcelos de Lacerda; Marco Antonio Bottino; Cecilia Pedroso Turssi; Roberta Tarkany Basting; Flávia Lucisano Botelho do Amaral; Fabiana Mantovani Gomes França
Journal:  Materials (Basel)       Date:  2022-08-03       Impact factor: 3.748

8.  Influence of Manufacturing Methods of Implant-Supported Crowns on External and Internal Marginal Fit: A Micro-CT Analysis.

Authors:  Izabela C M Moris; Silas Borges Monteiro; Raíssa Martins; Ricardo Faria Ribeiro; Erica A Gomes
Journal:  Biomed Res Int       Date:  2018-01-23       Impact factor: 3.411

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.