Literature DB >> 25218838

Relations between contact force, bipolar voltage amplitude, and mapping point distance from the left atrial surfaces of 3D ultrasound- and merged 3D CT-derived images: Implication for atrial fibrillation mapping and ablation.

Naoko Sasaki1, Yasuo Okumura2, Ichiro Watanabe1, Kazumasa Sonoda1, Rikitake Kogawa1, Keiko Takahashi1, Kazuki Iso1, Shiro Nakahara3, Ayako Maruyama4, Saya Takemura4, Atsushi Hirayama1.   

Abstract

BACKGROUND: Catheter tip-derived contact force (CF) and 3-dimensional (3D) maps are key to mapping and ablation of atrial fibrillation.
OBJECTIVE: This study sought to determine the relation between CF and 3D map surfaces.
METHODS: We conducted a validation study of Carto-based 3D ultrasound (3D-US) and 3D-US merged with computed tomography (3D-Merge-CT) left atrium/pulmonary vein images. Under fluoroscopic guidance, 1361 mapping points (20 patients) with CFs and electrogram information were randomly acquired around the PVs.
RESULTS: CF correlated weakly with the distance of mapping points from the 3D-Merge-CT (r = 0.27; P < .001) and 3D-US (r = 0.22; P < .001) surfaces but not with bipolar voltage (r = -0.01; P = .2400). Low CF (0-4 g) yielded points close to the 3D-US surface; moderate (5-9 g) and high CFs (10-20 g) generated points beyond the surface (0.1 ± 3.9, 1.4 ± 3.4, and 2.3 ± 3.4 mm; P < .05 for each). Low, moderate, and high CFs yielded points below, close to, and beyond the 3D-Merge-CT surface (-1.2 ± 3.7, 0.4 ± 3.0, and 1.0 ± 2.9 mm; P < .05 for each).
CONCLUSION: Poor correlation between CF and the distance of mapping points from the 3D map surfaces and electrogram information shows the limitation of 3D mapping and electrogram information for predicting good contact. In addition, mapping seems to require far less CF than ablation requires.
Copyright © 2015 Heart Rhythm Society. Published by Elsevier Inc. All rights reserved.

Entities:  

Keywords:  3D CT image; 3D ultrasound image; Bipolar voltage amplitude; Contact force

Mesh:

Year:  2014        PMID: 25218838     DOI: 10.1016/j.hrthm.2014.09.007

Source DB:  PubMed          Journal:  Heart Rhythm        ISSN: 1547-5271            Impact factor:   6.343


  8 in total

1.  Optimal local impedance drops for an effective radiofrequency ablation during cavo-tricuspid isthmus ablation.

Authors:  Takehito Sasaki; Kohki Nakamura; Mitsuho Inoue; Kentaro Minami; Yuko Miki; Koji Goto; Yutaka Take; Kenichi Kaseno; Eiji Yamashita; Keiko Koyama; Shigeto Naito
Journal:  J Arrhythm       Date:  2020-07-16

Review 2.  Better Lesion Creation And Assessment During Catheter Ablation.

Authors:  Saurabh Kumar; Chirag R Barbhaiya; Samuel Balindger; Roy M John; Laurence M Epstein; Bruce A Koplan; Usha B Tedrow; William G Stevenson; Gregory F Michaud
Journal:  J Atr Fibrillation       Date:  2015-10-31

Review 3.  Catheter Ablation of Atrial Fibrillation Without Radiation Exposure Using A 3D Mapping System.

Authors:  Marco Scaglione; Elisa Ebrille; Francesca Di Clemente; Fiorenzo Gaita; Jason S Bradfield
Journal:  J Atr Fibrillation       Date:  2015-02-28

Review 4.  Left atrial voltage mapping: defining and targeting the atrial fibrillation substrate.

Authors:  Iain Sim; Martin Bishop; Mark O'Neill; Steven E Williams
Journal:  J Interv Card Electrophysiol       Date:  2019-05-10       Impact factor: 1.900

Review 5.  Applications of multimodality imaging for left atrial catheter ablation.

Authors:  Caroline H Roney; Charles Sillett; John Whitaker; Jose Alonso Solis Lemus; Iain Sim; Irum Kotadia; Mark O'Neill; Steven E Williams; Steven A Niederer
Journal:  Eur Heart J Cardiovasc Imaging       Date:  2021-12-18       Impact factor: 6.875

6.  The effect of activation rate on left atrial bipolar voltage in patients with paroxysmal atrial fibrillation.

Authors:  Steven E Williams; Nick Linton; Louisa O'Neill; James Harrison; John Whitaker; Rahul Mukherjee; Christopher A Rinaldi; Jaswinder Gill; Steven Niederer; Matthew Wright; Mark O'Neill
Journal:  J Cardiovasc Electrophysiol       Date:  2017-09

7.  Early and Delayed Alteration of Atrial Electrograms Around Single Radiofrequency Ablation Lesion.

Authors:  Stepan Havranek; Hana Alfredova; Zdenka Fingrova; Lucie Souckova; Dan Wichterle
Journal:  Front Cardiovasc Med       Date:  2019-01-08

8.  Diagnostic accuracy of three-dimensional contrast-enhanced ultrasound for focal liver lesions: A protocol for systematic review and meta-analysis.

Authors:  Meijng Qu; Zhaohua Jia; Lipeng Sun; Hui Wang
Journal:  Medicine (Baltimore)       Date:  2021-12-23       Impact factor: 1.817

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.