Literature DB >> 25216693

Accurate Xe isotope measurement using JPL ion trap.

Stojan M Madzunkov1, Dragan Nikolić.   

Abstract

We report an approach for the reproducible and accurate compositional analysis of different mixtures of Xe isotopes using miniature Jet Propulsion Laboratory Quadrupole Ion Trap (JPL-QIT). A major study objective was to validate the recent instrumental improvements to the long-term operational stability under different pressures, temperatures, and trapping conditions. We propose that the present device can be used in certification of trace amounts of isotopes in mixtures dominated by one or more isotopes. Measured isotopic compositions are verified against commercially available standards with accuracy better than 0.07%. To aid the analysis of experimental data, we developed a scalable replica fitting method and use peak areas as descriptors of relative isotopic abundances. This low-power and low-mass device is ideally suited for planetary explorations aimed to enhance quantitative analysis for major isotopes present in small amounts of atmospheric samples.

Entities:  

Year:  2014        PMID: 25216693     DOI: 10.1007/s13361-014-0980-2

Source DB:  PubMed          Journal:  J Am Soc Mass Spectrom        ISSN: 1044-0305            Impact factor:   3.109


  5 in total

1.  Improved method for peak picking in matrix-assisted laser desorption/ionization time-of-flight mass spectrometry.

Authors:  Martin Kempka; Johan Sjödahl; Anders Björk; Johan Roeraade
Journal:  Rapid Commun Mass Spectrom       Date:  2004       Impact factor: 2.419

Review 2.  Stardust in meteorites.

Authors:  Andrew M Davis
Journal:  Proc Natl Acad Sci U S A       Date:  2011-11-21       Impact factor: 11.205

3.  A general approach to modeling biphasic relationships.

Authors:  William N Beckon; Cary Parkins; Alexey Maximovich; Angela V Beckon
Journal:  Environ Sci Technol       Date:  2008-02-15       Impact factor: 9.028

4.  Digitally synthesized high purity, high-voltage radio frequency drive electronics for mass spectrometry.

Authors:  R T Schaefer; J A MacAskill; M Mojarradi; A Chutjian; M R Darrach; S M Madzunkov; B J Shortt
Journal:  Rev Sci Instrum       Date:  2008-09       Impact factor: 1.523

5.  Consistent van der Waals radii for the whole main group.

Authors:  Manjeera Mantina; Adam C Chamberlin; Rosendo Valero; Christopher J Cramer; Donald G Truhlar
Journal:  J Phys Chem A       Date:  2009-05-14       Impact factor: 2.781

  5 in total
  1 in total

1.  Computer Modeling of an Ion Trap Mass Analyzer, Part I: Low Pressure Regime.

Authors:  Dragan Nikolić; Stojan M Madzunkov; Murray R Darrach
Journal:  J Am Soc Mass Spectrom       Date:  2015-08-19       Impact factor: 3.109

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.