Literature DB >> 25203572

Evaluation of the accuracy of linear measurements on lateral cephalograms obtained from cone-beam computed tomography scans with digital lateral cephalometric radiography: an in vitro study.

Abbas Shokri1, Samira Khajeh, Atefeh Khavid.   

Abstract

OBJECTIVES: A cephalometric analysis especially designed for the patient who requires maxillofacial surgery was developed to use landmarks and measurements that can be altered by common surgical procedures. Identification of landmarks in cephalometry is very important and useful for orthognathic surgery. The aim of this study was to evaluate the accuracy of linear measurement based on digital lateral cephalograms (DLC) and on lateral cephalograms obtained from cone-beam computed tomography (CBCT) scans.
MATERIALS AND METHODS: The linear distances between anatomic landmarks on 6 dry human skulls were measured by 2 observers using digital calipers for sella-nasion (S-N), menton-nasion (M-N), anterior nasal spine-nasion (ANS-N), anterior nasal spine-posterior nasal spine (ANS-PNS), and pogonion-gonion (Pog-Go). Then, images were obtained by using DLCs and in lateral cephalograms obtained from CBCT scans. The measurement errors were calculated for each modality, compared with each other, and analyzed via SPSS software version 18.
RESULTS: For all lines (S-N, M-N, ANS-N, Pog-Go, and ANS-PNS), CBCT-derived values did not differ from actual dry skull dimensions (gold standard) (P > 0.05). In DLC, for S-N, M-N, ANS-N, and Pog-Go lines, measurements were significantly higher than actual measurements (P ≤ 0.05), but ANS-PNS values did not differ from actual measurements (P > 0.05).
CONCLUSIONS: The results showed that the values obtained in CBCT imaging compared with calculated values of the digital lateral cephalometry much closer to the actual distance are more accurate indicators of this type of imaging and that CBCT permits oral surgeons to visualize the position and surgical anatomy of the tooth as it will be seen in the operating theater and allows orthodontists to plan directional traction.

Entities:  

Mesh:

Year:  2014        PMID: 25203572     DOI: 10.1097/SCS.0000000000000908

Source DB:  PubMed          Journal:  J Craniofac Surg        ISSN: 1049-2275            Impact factor:   1.046


  7 in total

1.  Modern 3D cephalometry in pediatric orthodontics-downsizing the FOV and development of a new 3D cephalometric analysis within a minimized large FOV for dose reduction.

Authors:  Pamela Kissel; James K Mah; Axel Bumann
Journal:  Clin Oral Investig       Date:  2021-01-25       Impact factor: 3.573

2.  Position of the hyoid bone and its correlation with airway dimensions in different classes of skeletal malocclusion using cone-beam computed tomography.

Authors:  Abbas Shokri; Vahid Mollabashi; Foozie Zahedi; Leili Tapak
Journal:  Imaging Sci Dent       Date:  2020-06-18

3.  Effect of exposure parameters of cone beam computed tomography on metal artifact reduction around the dental implants in various bone densities.

Authors:  Abbas Shokri; Mohammad Reza Jamalpour; Atefeh Khavid; Zeinab Mohseni; Masoud Sadeghi
Journal:  BMC Med Imaging       Date:  2019-04-29       Impact factor: 1.930

4.  The Effects of Additional Filtration on Image Quality and Radiation Dose in Cone Beam CT: An In Vivo Preliminary Investigation.

Authors:  Jan Houfrar; Bjorn Ludwig; Dirk Bister; Manuel Nienkemper; Ciamak Abkai; Adith Venugopal
Journal:  Biomed Res Int       Date:  2022-03-02       Impact factor: 3.411

5.  Diagnostic Accuracy of Three Cone Beam Computed Tomography Systems and Periapical Radiography for Detection of Fenestration Around Dental Implants.

Authors:  Amir Eskandarloo; Samira Saati; Mahbubeh Purabdolahi Ardakani; Mohamadreza Jamalpour; Naser Mohammad Gholi Mezerji; Vahid Akheshteh
Journal:  Contemp Clin Dent       Date:  2018 Jul-Sep

Review 6.  A novel method for the management of proximal segment using computer assisted simulation surgery: correct condyle head positioning and better proximal segment placement.

Authors:  Yong-Chan Lee; Hong-Bum Sohn; Sung-Keun Kim; On-Yu Bae; Jang-Ha Lee
Journal:  Maxillofac Plast Reconstr Surg       Date:  2015-08-04

7.  Effect of field-of-view size on gray values derived from cone-beam computed tomography compared with the Hounsfield unit values from multidetector computed tomography scans.

Authors:  Abbas Shokri; Leila Ramezani; Mohsen Bidgoli; Mahdi Akbarzadeh; Karim Ghazikhanlu-Sani; Hamed Fallahi-Sichani
Journal:  Imaging Sci Dent       Date:  2018-03-19
  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.