Literature DB >> 25201264

Biomechanical analysis and clinical effects of bridge combined fixation system for femoral fractures.

Da-xing Wang1, Ying Xiong2, Hong Deng1, Fu Jia1, Shao Gu1, Bai-lian Liu1, Qun-hui Li1, Qi Pu1, Zhong-Zi Zhang1.   

Abstract

This work aimed to compare the stress distribution and mechanical properties of our bridge combined fixation system and commonly used metal locking plate screw system by finite element analysis and by using the Zwick/Z100 testing machine. In addition, we also investigated the clinical outcome of our bridge combined fixation system for femoral fractures in 59 patients from June 2005 to January 2013. As a result, the stress distribution in the bone plate and screws of metal locking plate screw system during walking and climbing stairs was significantly lower than that of metal locking plate screw system. No significant difference in the displacement was observed between two systems. The equivalent bending stiffness of bridge combined fixation system was significantly lower than that of metal locking plate screw system. There were no significant differences in the bending strength, yield load, and maximum force between two systems. All the cases were followed up for 12-24 months (average 18 months). The X-ray showed bone callus was formed in most patients after 3 months, and the fracture line was faint and disappeared at 6-9 months postoperatively. No serious complications, such as implant breakage and wound infection, occurred postoperatively. According to self-developed standard for bone healing, clinical outcomes were rated as excellent or good in 55 out of 59 patients (success rate: 93.2%). Therefore, our findings suggest that our bridge combined fixation system may be a promising approach for treatment of long-bone fractures. © IMechE 2014.

Entities:  

Keywords:  Finite element model; bridge combined fixation system; clinical research; metal locking plate screw system

Mesh:

Year:  2014        PMID: 25201264     DOI: 10.1177/0954411914548866

Source DB:  PubMed          Journal:  Proc Inst Mech Eng H        ISSN: 0954-4119            Impact factor:   1.617


  7 in total

1.  Optimal configuration of a three-rod ortho-bridge system in the treatment of Vancouver type B1 periprosthetic femoral fractures: A finite element analysis.

Authors:  Md Ariful Haque; Marcos Roberto Tovani-Palone; Thomas Franchi; Long Zhang; Jing Qin; Luyun Liu; Yingjie Zhang; Ying Xiong; Tong Wu; Jiayu Xiao
Journal:  J Orthop       Date:  2022-02-26

2.  Femoral periprosthetic fracture treatment using the Ortho-Bridge System: a biomechanical study.

Authors:  Yuntao Long; Yubin Qi; Guilai Zuo; Qingjie Zhang; Zhenlin Liu; Wen Wang
Journal:  J Orthop Surg Res       Date:  2022-06-03       Impact factor: 2.677

3.  Comparison of 2 Different Fixation Implants for Operative Treatment of Mid-Shaft Clavicle Fractures: A Retrospective Study.

Authors:  Xindie Zhou; Jin Li; Haoyu Yang; Dong Li; Junjie Zhang; Yi Zhang; Yong Huang; Nanwei Xu
Journal:  Med Sci Monit       Date:  2019-12-19

4.  Analysis of Efficacy, Complications, and Inflammatory Reactions of Bridge Combined Internal Fixation System for Periarticular Fractures of the Shoulder.

Authors:  Haiyun Xu; Youliang Fan; Jiajun Lu; Yixiong Wu; Xiaoguang Feng
Journal:  Comput Math Methods Med       Date:  2022-08-21       Impact factor: 2.809

Review 5.  Experimental testing of fracture fixation plates: A review.

Authors:  Shiling Zhang; Dharmesh Patel; Mark Brady; Sherri Gambill; Kanthan Theivendran; Subodh Deshmukh; John Swadener; Sarah Junaid; Laura Jane Leslie
Journal:  Proc Inst Mech Eng H       Date:  2022-08-03       Impact factor: 1.763

6.  Effectiveness and Biomechanical Analysis of the Ortho-Bridge System on Femoral Fracture Healing: A Retrospective Analysis.

Authors:  Yubin Qi; Lin Yao; Yuntao Long; Guilai Zuo; Qingjie Zhang; Zhenlin Liu; Wen Wang
Journal:  Indian J Orthop       Date:  2022-08-09       Impact factor: 1.033

7.  Ipsilateral proximal and shaft femoral fractures treated with bridge-link type combined fixation system.

Authors:  Liangqi Kang; Hui Liu; Zhenqi Ding; Yiqiang Ding; Wei Hu; Jin Wu
Journal:  J Orthop Surg Res       Date:  2020-09-10       Impact factor: 2.359

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.