Literature DB >> 25199069

Comparative effect of different polymerization techniques on residual monomer and hardness properties of PMMA-based denture resins.

Elif Aydogan Ayaz1, Rukiye Durkan, Ayşegul Koroglu, Bora Bagis.   

Abstract

PURPOSE: The aim of this study was to compare the residual monomer and microhardness of poly(methyl methacrylate) (PMMA)-based denture resins processed by using autoclave and conventional water bath techniques.
METHODS: To determine the amount of residual methyl methacrylate (MMA) monomer, disk-shaped specimens (n=5) were prepared from 3 different acrylic resins (Meliodent, Paladent and Qc-20). Control groups were polymerized in water bath for 30 minutes at 100°C. The study groups were prepared in an autoclave device for 60°C/30 min followed 130°C/10 min and the other group for 60°C/30 min followed by 130°C/20 min. According to standard calibration curves, ultraviolet spectrophotometry at 230 nm was used to determine the residual monomer. For the Vickers hardness measurements, disk-shaped specimens (n=5) were prepared for each test group. Hardness measurements were performed with a Vickers hardness tester under a 4.91-N press load for a 30 seconds, after immersion in distilled water at 37ºC for 48 hours. The data were analyzed by ANOVA and Tukey HSD test (p<0.05).
RESULTS: Autoclave polymerization produced a significant decrease in the amount of residual monomers for all resin groups (p<0.05). This procedure also showed a significant increase in hardness for all resin groups (p<0.05). For the 3 resin groups, no significant differences were found between autoclave polymerization for 10 minutes and for 20 minutes (p>0.05).
CONCLUSIONS: The autoclave polymerization technique exhibited significantly lower residual monomer content and greater hardness than conventional heat polymerization.

Entities:  

Mesh:

Substances:

Year:  2014        PMID: 25199069     DOI: 10.5301/jabfm.5000199

Source DB:  PubMed          Journal:  J Appl Biomater Funct Mater        ISSN: 2280-8000            Impact factor:   2.604


  13 in total

1.  Flexural Properties, Impact Strength, and Hardness of Nanodiamond-Modified PMMA Denture Base Resin.

Authors:  Shaimaa M Fouda; Mohammed M Gad; Passent Ellakany; Maram A Al Ghamdi; Soban Q Khan; Sultan Akhtar; Mohamed S Ali; Fahad A Al-Harbi
Journal:  Int J Biomater       Date:  2022-07-09

Review 2.  Mechanical Properties of the Modified Denture Base Materials and Polymerization Methods: A Systematic Review.

Authors:  Aftab Ahmed Khan; Muhammad Amber Fareed; Abdulkarim Hussain Alshehri; Alhanoof Aldegheishem; Rasha Alharthi; Selma A Saadaldin; Muhammad Sohail Zafar
Journal:  Int J Mol Sci       Date:  2022-05-20       Impact factor: 6.208

3.  Plasticizers and Salt Concentrations Effects on Polymer Gel Electrolytes Based on Poly (Methyl Methacrylate) for Electrochemical Applications.

Authors:  Carmen Rizzuto; Dale C Teeters; Riccardo C Barberi; Marco Castriota
Journal:  Gels       Date:  2022-06-08

4.  Impact of Polymerization Technique and ZrO2 Nanoparticle Addition on the Fracture Load of Interim Implant-Supported Fixed Cantilevered Prostheses in Comparison to CAD/CAM Material.

Authors:  Faris A Alshahrani; Shorouq Khalid Hamid; Lujain Ali Alghamdi; Firas K Alqarawi; Yousif A Al-Dulaijan; Hamad S AlRumaih; Haidar Alalawi; Maram A Al Ghamdi; Fawaz Alzoubi; Mohammed M Gad
Journal:  Dent J (Basel)       Date:  2022-06-08

5.  Effect of Novel Cycloaliphatic Comonomer on Surface Roughness and Surface Hardness of Heat-cure Denture Base Resin.

Authors:  Ranganathan Ajay; Karthigeyan Suma; Vikraman Rakshagan; Elumalai Ambedkar; Vellingiri Lalithamanohari; Murugesan Sreevarun
Journal:  J Pharm Bioallied Sci       Date:  2020-08-28

6.  Influence of polymerization method on the cytotoxicity of three different denture base acrylic resins polymerized in different methods.

Authors:  Zbigniew Raszewski
Journal:  Saudi J Biol Sci       Date:  2020-06-01       Impact factor: 4.219

7.  Discoloration of PMMA, composite, and PEEK.

Authors:  Sina Heimer; Patrick R Schmidlin; Bogna Stawarczyk
Journal:  Clin Oral Investig       Date:  2016-06-25       Impact factor: 3.573

8.  Analysis of residual crosslinking agent content in UV cross-linked poly(ethylene oxide) hydrogels for dermatological application by gas chromatography.

Authors:  Rachel Shet Hui Wong; Mark Ashton; Kalliopi Dodou
Journal:  J Pharm Anal       Date:  2016-04-09

9.  Spectrophotometric Evaluation of Polyetheretherketone (PEEK) as a Core Material and a Comparison with Gold Standard Core Materials.

Authors:  Bogna Stawarczyk; Philipp Schmid; Malgorzata Roos; Marlis Eichberger; Patrick R Schmidlin
Journal:  Materials (Basel)       Date:  2016-06-20       Impact factor: 3.623

10.  Cinnamaldehyde is a biologically active compound for the disinfection of removable denture: blinded randomized crossover clinical study.

Authors:  Marco Antônio Lavorato de Almeida; André Ulisses Dantas Batista; Maria Rejane Cruz de Araújo; Vanessa Fabiana Dei Santi de Almeida; Paulo Rogério Ferreti Bonan; Danielle Nóbrega Alves; Tereza Karla Vieira Lopes da Costa; Diego Figueiredo Nóbrega; Ricardo Dias de Castro
Journal:  BMC Oral Health       Date:  2020-08-17       Impact factor: 2.757

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.