AIM: To assess, in a randomized study, the implant (clinical and radiological) and patient outcomes of guided implant placement at 1-year follow-up, compared to conventional implant treatment. MATERIAL AND METHODS:A total of 314 were placed in 59 patients, randomly assigned to one of the treatment groups. Radiographic and clinical parameters were recorded at the time of implant placement, prosthesis instalment (baseline) and at 1-year follow-up. Patient satisfaction was measured with the oral health-related quality of life instrument (OHIP-49). RESULTS: No implants were lost. The mean marginal bone loss after the first year of loading was 0.04 mm (SD 0.34) for the guided surgery and 0.01 mm (SD 0.38) for the control groups. In the guided surgery groups, the mean number of surfaces with BOP and plaque at 1-year follow-up was 1.41 (SD 1.25) and 1.10 (SD 1.22), for the control groups this was, respectively, 1.37 (SD 1.25) and 1.77 (SD 1.64). The mean pocket probing depth was 2.81 mm (SD 1.1) for the guided, and 2.50 mm (SD 0.94) for the control groups. For all treatment groups, a significant improvement in quality of life was observed at 1-year follow-up (p ≤ 0.01), no differences between groups were observed. CONCLUSION: Within the limitations of this study, no difference could be found at 1-year follow-up between the implant and patient outcome variables of guided or conventional implant treatment.
RCT Entities:
AIM: To assess, in a randomized study, the implant (clinical and radiological) and patient outcomes of guided implant placement at 1-year follow-up, compared to conventional implant treatment. MATERIAL AND METHODS: A total of 314 were placed in 59 patients, randomly assigned to one of the treatment groups. Radiographic and clinical parameters were recorded at the time of implant placement, prosthesis instalment (baseline) and at 1-year follow-up. Patient satisfaction was measured with the oral health-related quality of life instrument (OHIP-49). RESULTS: No implants were lost. The mean marginal bone loss after the first year of loading was 0.04 mm (SD 0.34) for the guided surgery and 0.01 mm (SD 0.38) for the control groups. In the guided surgery groups, the mean number of surfaces with BOP and plaque at 1-year follow-up was 1.41 (SD 1.25) and 1.10 (SD 1.22), for the control groups this was, respectively, 1.37 (SD 1.25) and 1.77 (SD 1.64). The mean pocket probing depth was 2.81 mm (SD 1.1) for the guided, and 2.50 mm (SD 0.94) for the control groups. For all treatment groups, a significant improvement in quality of life was observed at 1-year follow-up (p ≤ 0.01), no differences between groups were observed. CONCLUSION: Within the limitations of this study, no difference could be found at 1-year follow-up between the implant and patient outcome variables of guided or conventional implant treatment.
Authors: Cornelia Edelmann; Martin Wetzel; Anne Knipper; Ralph G Luthardt; Sigmar Schnutenhaus Journal: J Clin Med Date: 2021-04-21 Impact factor: 4.241
Authors: Ali Al-Rimawi; Mostafa EzEldeen; Danilo Schneider; Constantinus Politis; Reinhilde Jacobs Journal: Int J Environ Res Public Health Date: 2019-02-11 Impact factor: 3.390
Authors: Javier Montero; Javier Dolz; Francisco-Javier Silvestre; Javier Flores; Abraham Dib; Cristina Gómez-Polo Journal: Odontology Date: 2019-01-16 Impact factor: 2.634
Authors: Sigmar Schnutenhaus; Anne Knipper; Martin Wetzel; Cornelia Edelmann; Ralph Luthardt Journal: Int J Environ Res Public Health Date: 2021-03-21 Impact factor: 3.390