Literature DB >> 25189647

Immediate effects of breath holding maneuvers onto composition of exhaled breath.

Pritam Sukul1, Phillip Trefz, Jochen K Schubert, Wolfram Miekisch.   

Abstract

Rapid concentration changes due to physiological or pathophysiological effects rather than appearance of unique disease biomarkers are important for clinical application of breath research. Simple maneuvers such as breath holding may significantly affect breath biomarker concentrations. In this study, exhaled volatile organic compound (VOC) concentrations were assessed in real time before and after different breath holding maneuvers. Continuous breath-resolved measurements (PTR-ToF-MS-8000) were performed in 31 healthy human subjects in a side-stream sampling mode. After 1 min of tidal breathing participants held their breath for 10, 20, 40, 60 s and as long as possible. Afterwards they continued to breathe normally for another minute. VOC profiles could be monitored in real time by assigning online PTR-ToF-MS data to alveolar or inspired phases of breath. Sudden and profound changes of exhaled VOC concentrations were recorded after different breath holding maneuvers. VOC concentrations returned to base line levels 10-20 s after breath holding. Breath holding induced concentration changes depended on physico-chemical properties of the substances. When substance concentrations were normalized onto end-tidal CO2 content, variation of acetone concentrations decreased, whereas variations of isoprene concentrations were not affected. As the effects of breathing patterns on exhaled substance concentrations depend on individual substance properties, sampling procedures have to be validated for each compound by means of appropriate real-time analysis. Normalization of exhaled concentrations onto exhaled CO2 is only valid for substances having similar physico-chemical properties as CO2.

Entities:  

Mesh:

Substances:

Year:  2014        PMID: 25189647     DOI: 10.1088/1752-7155/8/3/037102

Source DB:  PubMed          Journal:  J Breath Res        ISSN: 1752-7155            Impact factor:   3.262


  20 in total

1.  Investigation of altered urinary metabolomic profiles of invasive ductal carcinoma of breast using targeted and untargeted approaches.

Authors:  Tushar H More; Ravindra Taware; Khushman Taunk; Venkatesh Chanukuppa; Venkateshwarlu Naik; Anupama Mane; Srikanth Rapole
Journal:  Metabolomics       Date:  2018-08-10       Impact factor: 4.290

2.  Cellular respiration, metabolomics and the search for illicit drug biomarkers in breath: report from PittCon 2017.

Authors:  Joachim Pleil; Jonathan Beauchamp; Wolfram Miekisch
Journal:  J Breath Res       Date:  2017-08-04       Impact factor: 3.262

Review 3.  Evolution of clinical and environmental health applications of exhaled breath research: Review of methods and instrumentation for gas-phase, condensate, and aerosols.

Authors:  M Ariel Geer Wallace; Joachim D Pleil
Journal:  Anal Chim Acta       Date:  2018-02-09       Impact factor: 6.558

4.  Modeling-based determination of physiological parameters of systemic VOCs by breath gas analysis: a pilot study.

Authors:  Karl Unterkofler; Julian King; Pawel Mochalski; Martin Jandacka; Helin Koc; Susanne Teschl; Anton Amann; Gerald Teschl
Journal:  J Breath Res       Date:  2015-05-14       Impact factor: 3.262

5.  Cinema audiences reproducibly vary the chemical composition of air during films, by broadcasting scene specific emissions on breath.

Authors:  Jonathan Williams; Christof Stönner; Jörg Wicker; Nicolas Krauter; Bettina Derstroff; Efstratios Bourtsoukidis; Thomas Klüpfel; Stefan Kramer
Journal:  Sci Rep       Date:  2016-05-10       Impact factor: 4.379

6.  Natural menstrual rhythm and oral contraception diversely affect exhaled breath compositions.

Authors:  Pritam Sukul; Jochen K Schubert; Phillip Trefz; Wolfram Miekisch
Journal:  Sci Rep       Date:  2018-07-18       Impact factor: 4.379

Review 7.  Unravelling the Potential of Salivary Volatile Metabolites in Oral Diseases. A Review.

Authors:  Jorge A M Pereira; Priscilla Porto-Figueira; Ravindra Taware; Pritam Sukul; Srikanth Rapole; José S Câmara
Journal:  Molecules       Date:  2020-07-07       Impact factor: 4.411

Review 8.  Measuring breath acetone for monitoring fat loss: Review.

Authors:  Joseph C Anderson
Journal:  Obesity (Silver Spring)       Date:  2015-11-02       Impact factor: 5.002

9.  FEV manoeuvre induced changes in breath VOC compositions: an unconventional view on lung function tests.

Authors:  Pritam Sukul; Jochen K Schubert; Peter Oertel; Svend Kamysek; Khushman Taunk; Phillip Trefz; Wolfram Miekisch
Journal:  Sci Rep       Date:  2016-06-17       Impact factor: 4.379

Review 10.  Exhaled breath analysis: a review of 'breath-taking' methods for off-line analysis.

Authors:  Oluwasola Lawal; Waqar M Ahmed; Tamara M E Nijsen; Royston Goodacre; Stephen J Fowler
Journal:  Metabolomics       Date:  2017-08-19       Impact factor: 4.290

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.