| Literature DB >> 25187034 |
Zhipeng Lei1, Xuewu Ji2, Ning Li1, James Yang3, Ziqing Zhuang4, Dana Rottach4.
Abstract
In a respirator fit test, a subject is required to perform a series of exercises that include moving the head up and down and rotating the head left and right. These head movements could affect respirator sealing properties during the fit test and consequently affect fit factors. In a model-based system, it is desirable to have similar capability to predict newly designed respirators. In our previous work, finite element modeling (FEM)-based contact simulation between a headform and a filtering facepiece respirator was carried out. However, the headform was assumed to be static or fixed. This paper presents the first part of a series study on the effect of headform movement on contact pressures-a new headform with the capability to move down (flexion), up (extension), and rotate left and right-and validation. The newly developed headforms were validated for movement by comparing the simulated cervical vertebrae rotation angles with experimental results from the literature.Entities:
Keywords: contact pressure; filtering facepiece respirator; finite element method; head movement; headform
Mesh:
Year: 2014 PMID: 25187034 PMCID: PMC5504518 DOI: 10.1093/annhyg/meu051