Literature DB >> 25183591

Total hip replacement through a posterior approach using a 22 mm diameter femoral head : the role of the transverse acetabular ligament and capsular repair in reducing the rate of dislocation.

V Kumar1, S Sharma2, J James1, J P Hodgkinson1, M V Hemmady1.   

Abstract

Despite a lack of long-term follow-up, there is an increasing trend towards using femoral heads of large diameter in total hip replacement (THR), partly because of the perceived advantage of lower rates of dislocation. However, increasing the size of the femoral head is not the only way to reduce the rate of dislocation; optimal alignment of the components and repair of the posterior capsule could achieve a similar effect. In this prospective study of 512 cemented unilateral THRs (Male:Female 230:282) performed between 2004 and 2011, we aimed to determine the rate of dislocation in patients who received a 22 mm head on a 9/10 Morse taper through a posterior approach with capsular repair and using the transverse acetabular ligament (TAL) as a guide for the alignment of the acetabular component. The mean age of the patients at operation was 67 years (35 to 89). The mean follow-up was 2.8 years (0.5 to 6.6). Pre- and post-operative assessment included Oxford hip, Short Form-12 and modified University of California Los Angeles and Merle D'Aubigne scores. The angles of inclination and anteversion of the acetabular components were measured using radiological software. There were four dislocations (0.78%), all of which were anterior. In conclusion, THR with a 22 mm diameter head performed through a posterior approach with capsular repair and using the TAL as a guide for the alignment of the acetabular component was associated with a low rate of dislocation. ©2014 The British Editorial Society of Bone & Joint Surgery.

Entities:  

Keywords:  Total hip replacement; Posterior approach; 22 mm femoral head; TAL; Dislocation

Mesh:

Year:  2014        PMID: 25183591     DOI: 10.1302/0301-620X.96B9.31831

Source DB:  PubMed          Journal:  Bone Joint J        ISSN: 2049-4394            Impact factor:   5.082


  5 in total

1.  Arthroscopic Capsular Reconstruction of the Hip With Acellular Dermal Extracellular Matrix: Surgical Technique.

Authors:  Itay Perets; David E Hartigan; John P Walsh; Edwin Chaharbakhshi; Mary R Close; Benjamin G Domb
Journal:  Arthrosc Tech       Date:  2016-09-05

2.  Effect of changing femoral head diameter on bony and prosthetic jumping angles.

Authors:  Takaaki Ohmori; Tamon Kabata; Yoshitomo Kajino; Daisuke Inoue; Tadashi Taga; Takashi Yamamoto; Tomoharu Takagi; Junya Yoshitani; Takuro Ueno; Ken Ueoka; Hiroyuki Tsuchiya
Journal:  Eur J Orthop Surg Traumatol       Date:  2018-10-30

3.  [Mid- and long-term effectiveness of total hip arthroplasty with Ribbed femoral stem prosthesis in 354 cases].

Authors:  Tao Yang; Jie Xie; Yihe Hu; Senbo An; Long Wang
Journal:  Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi       Date:  2019-09-15

4.  Surgical Approaches for Total Hip Arthroplasty.

Authors:  Vincent M Moretti; Zachary D Post
Journal:  Indian J Orthop       Date:  2017 Jul-Aug       Impact factor: 1.251

5.  Anterior and antero-lateral mini-invasive approaches for primary total hip replacement.

Authors:  Lorenzo Ponziani; Francesco Di Caprio; Francesco Tentoni; Simone Grana; Antimo Di Meo; Marina Gigli
Journal:  Acta Biomed       Date:  2021-07-26
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.