Literature DB >> 25183459

Correlation between the ganglion cell complex and structural measures of the optic disc and retinal nerve fiber layer in glaucoma.

Erica Bresciani-Battilana1, Ivan C Teixeira, Diego T Q Barbosa, Cristiano Caixeta-Umbelino, Maurício D Paolera, Niro Kasahara.   

Abstract

To correlate the ganglion cell complex (GCC) parameters with structural measures of the optic nerve head (ONH) and retinal nerve fiber layer (RNFL) as evaluated by Fourier-Domain optic coherence tomography (OCT). This retrospective study included patients with glaucoma, ocular hypertensive patients and glaucoma suspects who had previously undergone OCT examination with the RTVue-100. The parameters of GCC (average, superior, inferior, focal loss volume [FLV], global loss volume [GLV]) were correlated with the values of the ONH (cup volume, cup area, horizontal cup-to-disk ratio, vertical cup-to-disk ratio, and rim area) and RNFL (average, superior, and inferior) using Pearson's correlation coefficient. The sample included 74 eyes of 37 patients. All correlations between GCC parameters and RNFL were strong (r > 0.60). The correlation between GCC parameters and ONH were good for most parameters, except that for FLV and cup volume (r = 0.13), GLV and cup volume (r = 0.09), and GLV and cup area (r = 0.21). The GCC parameters can be used as structural measures of the glaucomatous optic neuropathy.

Entities:  

Mesh:

Year:  2014        PMID: 25183459     DOI: 10.1007/s10792-014-9988-7

Source DB:  PubMed          Journal:  Int Ophthalmol        ISSN: 0165-5701            Impact factor:   2.031


  19 in total

1.  Ability of fourier-domain optical coherence tomography to detect retinal ganglion cell complex atrophy in glaucoma patients.

Authors:  Mehmet Sahin Sevim; Bulent Buttanri; Banu Torun Acar; Alev Kahya; Ece Turan Vural; Suphi Acar
Journal:  J Glaucoma       Date:  2013-09       Impact factor: 2.503

2.  Structure-function relationship of the macular visual field sensitivity and the ganglion cell complex thickness in glaucoma.

Authors:  Jung Hwa Na; Michael S Kook; Youngrok Lee; Seunghee Baek
Journal:  Invest Ophthalmol Vis Sci       Date:  2012-07-31       Impact factor: 4.799

3.  Ability of optical coherence tomography-determined ganglion cell complex thickness to total retinal thickness ratio to diagnose glaucoma.

Authors:  Yoshiyuki Kita; Ritsuko Kita; Asuka Takeyama; Seiji Takagi; Chiaki Nishimura; Goji Tomita
Journal:  J Glaucoma       Date:  2013-12       Impact factor: 2.503

4.  Evaluation of retinal nerve fiber layer, optic nerve head, and macular thickness measurements for glaucoma detection using optical coherence tomography.

Authors:  Felipe A Medeiros; Linda M Zangwill; Christopher Bowd; Roberto M Vessani; Remo Susanna; Robert N Weinreb
Journal:  Am J Ophthalmol       Date:  2005-01       Impact factor: 5.258

5.  Glaucomatous eye macular ganglion cell complex thickness and its relation to temporal circumpapillary retinal nerve fiber layer thickness.

Authors:  Yoshiyuki Kita; Ritsuko Kita; Ai Nitta; Chiaki Nishimura; Goji Tomita
Journal:  Jpn J Ophthalmol       Date:  2011-05-03       Impact factor: 2.447

6.  Diagnostic accuracy of nerve fibre layer, macular thickness and optic disc measurements made with the RTVue-100 optical coherence tomograph to detect glaucoma.

Authors:  A Garas; P Vargha; G Holló
Journal:  Eye (Lond)       Date:  2010-10-08       Impact factor: 3.775

7.  Macular segmentation with optical coherence tomography.

Authors:  Hiroshi Ishikawa; Daniel M Stein; Gadi Wollstein; Siobahn Beaton; James G Fujimoto; Joel S Schuman
Journal:  Invest Ophthalmol Vis Sci       Date:  2005-06       Impact factor: 4.799

8.  Clinical validity of macular ganglion cell complex by spectral domain-optical coherence tomography in advanced glaucoma.

Authors:  Mi-Sun Sung; Byung-Wan Kang; Hwang-Gyun Kim; Hwan Heo; Sang-Woo Park
Journal:  J Glaucoma       Date:  2014-08       Impact factor: 2.503

9.  Comparison of ganglion cell and retinal nerve fiber layer thickness in primary open-angle glaucoma and normal tension glaucoma with spectral-domain OCT.

Authors:  Penpe Gul Firat; Selim Doganay; Ersan Ersin Demirel; Cemil Colak
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2012-08-18       Impact factor: 3.117

10.  Detection of macular ganglion cell loss in glaucoma by Fourier-domain optical coherence tomography.

Authors:  Ou Tan; Vikas Chopra; Ake Tzu-Hui Lu; Joel S Schuman; Hiroshi Ishikawa; Gadi Wollstein; Rohit Varma; David Huang
Journal:  Ophthalmology       Date:  2009-09-10       Impact factor: 12.079

View more
  1 in total

1.  Correlation between the ganglion cell complex and functional measures in glaucoma patients and suspects.

Authors:  Ivan C Teixeira; Erica Bresciani-Battilana; Diego T Q Barbosa; Cristiano Caixeta-Umbelino; Maurício D Paolera; Niro Kasahara
Journal:  Int Ophthalmol       Date:  2014-11-26       Impact factor: 2.031

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.