Literature DB >> 25183254

Surface properties correlated with the human gingival fibroblasts attachment on various materials for implant abutments: a multiple regression analysis.

Young-Sung Kim1, Seung-Yun Shin, Seung-Kyun Moon, Seung-Min Yang.   

Abstract

OBJECTIVES: To reveal the suitable surface condition of an implant abutment for fibroblast attachment, the correlation between the surface characteristics of various materials and the human gingival fibroblast (HGF-1) attachment to the surfaces were analyzed.
METHODS: Six kinds of surfaces comprised of machined titanium alloy (SM), machined Co-Cr-Mo alloy (CCM), titanium nitride coated titanium alloy (TiN), anodized titanium alloy (AO), composite resin coating on titanium alloy (R) and zirconia (Zr) were used. The measured surface parameters were Sa, Sq, Sz, Sdr, Sdq, Sal, Str and water contact angle (WCA). The HGF-1 cell attachment was investigated and the correlations were analyzed using a multiple regression analysis.
RESULTS: The HGF-1 cell attachment was greater in the SM, TiN and Zr groups than the other groups and smallest in the CCM group (p = 0.0096). From the multiple regression analysis, the HGF-1 cell attachment was significantly correlated with Sdr, Sdq and WCA. When the R group was excluded, only WCA showed significant correlation with the fibroblast attachment.
CONCLUSIONS: Within the limitations of this study, the cell attachment of human gingival fibroblasts was correlated with WCA, developed interfacial area ratio and surface slope. When the surfaces with Sa values of ∼ 0.2 μm or less were concerned, only WCA showed a correlation in a third order manner.

Entities:  

Keywords:  dental abutments; dental implants; fibroblasts; surface properties; wettability

Mesh:

Substances:

Year:  2014        PMID: 25183254     DOI: 10.3109/00016357.2014.949845

Source DB:  PubMed          Journal:  Acta Odontol Scand        ISSN: 0001-6357            Impact factor:   2.331


  11 in total

1.  [Effect of different plasma treated zirconia on the adhensive behaviour of human gingival fibroblasts].

Authors:  M Zheng; L L Zhan; Z Q Liu; H P Li; J G Tan
Journal:  Beijing Da Xue Xue Bao Yi Xue Ban       Date:  2019-04-18

2.  Effect Morphology and Surface Treatment of the Abutments of Dental Implants on the Dimension and Health of Peri-Implant Biological Space.

Authors:  Ibrahim Dib-Zaitum; Yasmina Guadilla-González; Javier Flores-Fraile; Juan Dib-Zakkour; Lorena Benito-Garzón; Javier Montero
Journal:  Materials (Basel)       Date:  2022-06-22       Impact factor: 3.748

3.  Pre- and post-surgical evaluation of the inflammatory response in patients with aortic stenosis treated with different types of prosthesis.

Authors:  Maria Elena Soto; Jose Luis Salas; Jesus Vargas-Barron; Ricardo Marquez; Alejandra Rodriguez-Hernandez; Rafael Bojalil-Parra; Israel Pérez-Torres; Veronica Guarner-Lans
Journal:  BMC Cardiovasc Disord       Date:  2017-04-14       Impact factor: 2.298

4.  Novel Bio-functional Magnesium Coating on Porous Ti6Al4V Orthopaedic Implants: In vitro and In vivo Study.

Authors:  Xiaokang Li; Peng Gao; Peng Wan; Yifeng Pei; Lei Shi; Bo Fan; Chao Shen; Xin Xiao; Ke Yang; Zheng Guo
Journal:  Sci Rep       Date:  2017-01-19       Impact factor: 4.379

5.  The efficacy of convenient cleaning methods applicable for customized abutments: an in vitro study.

Authors:  Sunjai Kim; Changhun Choi; Yunsu Cha; Jae-Seung Chang
Journal:  BMC Oral Health       Date:  2021-02-18       Impact factor: 2.757

6.  Laser microgrooved vs. machined healing abutment disconnection/reconnection: a comparative clinical, radiographical and biochemical study with split-mouth design.

Authors:  Renzo Guarnieri; Gabriele Miccoli; Rodolfo Reda; Alessandro Mazzoni; Dario Di Nardo; Luca Testarelli
Journal:  Int J Implant Dent       Date:  2021-03-17

7.  Evaluation of concordance between CAD/CAM and clinical positions of abutment shoulder against mucosal margin: an observational study.

Authors:  Jan K Pietruski; Anna Skurska; Anna Bernaczyk; Robert Milewski; Maria Julia Pietruska; Peter Gehrke; Małgorzata D Pietruska
Journal:  BMC Oral Health       Date:  2018-05-02       Impact factor: 2.757

8.  Influence of scaling procedures on the integrity of titanium nitride coated CAD/CAM abutments.

Authors:  Peter Gehrke; Emmanouil Spanos; Carsten Fischer; Helmut Storck; Florian Tebbel; Dirk Duddeck
Journal:  J Adv Prosthodont       Date:  2018-06-12       Impact factor: 1.904

9.  TiO2 Coating and UV Photofunctionalization Enhance Blood Coagulation on Zirconia Surfaces.

Authors:  Khalil Shahramian; Aous Abdulmajeed; Ilkka Kangasniemi; Eva Söderling; Timo Närhi
Journal:  Biomed Res Int       Date:  2019-04-01       Impact factor: 3.411

10.  3D engineered human gingiva fabricated with electrospun collagen scaffolds provides a platform for in vitro analysis of gingival seal to abutment materials.

Authors:  Wichurat Sakulpaptong; Isabelle A Clairmonte; Britani N Blackstone; Binnaz Leblebicioglu; Heather M Powell
Journal:  PLoS One       Date:  2022-02-03       Impact factor: 3.240

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.