Literature DB >> 25179340

Microbial contamination of used dental handpieces.

Gordon Smith1, Andrew Smith2.   

Abstract

Microbial contamination of used, unprocessed internal components of dental handpieces (HPs) was assessed. HPs were dismantled aseptically, immersed in phosphate-buffered saline, ultrasonicated, and cultured. A median of 200 CFU per turbine (n = 40), 400 CFU per spray channel (n = 40), and 1000 CFU per item of surgical gear (n = 20) was detected. Isolates included oral streptococci, Pseudomonas spp, and Staphylococcus aureus. Recovery of S aureus confirms the need for appropriate HP cleaning and sterilization after each patient to prevent cross-infection.
Copyright © 2014 Association for Professionals in Infection Control and Epidemiology, Inc. Published by Mosby, Inc. All rights reserved.

Entities:  

Keywords:  Biofilm; Cross-infection; Dental turbine; Staphylococcus aureus

Mesh:

Year:  2014        PMID: 25179340     DOI: 10.1016/j.ajic.2014.06.008

Source DB:  PubMed          Journal:  Am J Infect Control        ISSN: 0196-6553            Impact factor:   2.918


  5 in total

Review 1.  Cross-transmission in the Dental Office: Does This Make You Ill?

Authors:  C M C Volgenant; J J de Soet
Journal:  Curr Oral Health Rep       Date:  2018-10-25

2.  An Evaluation of Two Systems for the Management of the Microbiological Quality of Water in Dental Unit Waterlines: Hygowater® and IGN Calbénium®.

Authors:  Damien Offner; Anne-Marie Musset
Journal:  Int J Environ Res Public Health       Date:  2021-05-20       Impact factor: 3.390

3.  Clinical Observation on the Disinfection of Turbine Water System to Minimize Postoperative Complications of Minimally Invasive Tooth Extraction.

Authors:  Qingtao Cheng; Penglai Wang; Wei Wang; Zongxiang Liu; Gang Liu; Xinfeng Zhang; Bei Ren; Jun Zhang
Journal:  Iran J Public Health       Date:  2015-12       Impact factor: 1.429

4.  Infection control in healthcare settings: perspectives for mfDNA analysis in monitoring sanitation procedures.

Authors:  Federica Valeriani; Carmela Protano; Gianluca Gianfranceschi; Paola Cozza; Vincenzo Campanella; Giorgio Liguori; Matteo Vitali; Maurizio Divizia; Vincenzo Romano Spica
Journal:  BMC Infect Dis       Date:  2016-08-09       Impact factor: 3.090

5.  Contamination of dental unit waterlines: assessment of three continuous water disinfection systems.

Authors:  Damien Offner; Florence Fioretti; Anne-Marie Musset
Journal:  BDJ Open       Date:  2016-12-16
  5 in total