Literature DB >> 25175597

Macrophage embedded fibrin gels: an in vitro platform for assessing inflammation effects on implantable glucose sensors.

Matthew T Novak1, Fan Yuan1, William M Reichert2.   

Abstract

The erroneous and unpredictable behavior of percutaneous glucose sensors just days following implantation has limited their clinical utility for diabetes management. Recent research has implicated the presence of adherent inflammatory cells as the key mitigating factor limiting sensor functionality in this period of days post-implantation. Here we present a novel in vitro platform to mimic the cell-embedded provisional matrix that forms adjacent to the sensor immediately after implantation for the focused investigation of the effects of early stage tissue response on sensor function. This biomimetic surrogate is formed by imbibing fibrin-based gels with physiological densities of inflammatory RAW 264.7 macrophages. When surrounding functional sensors, macrophage-embedded fibrin gels contribute to sensor signal declines that are similar in both shape and magnitude to those observed in previous whole blood and small animal studies. Signal decline in the presence of gels is both metabolically-mediated and sensitive to cell type and activation. Computational modeling of the experimental setup is also presented to validate the design by showing that the cellular glucose uptake parameters necessary to achieve such experimental declines align well with literature values. Together, these data suggest this in vitro provisional matrix surrogate may serve as an effective screening tool for testing the biocompatibility of future glucose sensor designs.
Copyright © 2014 Elsevier Ltd. All rights reserved.

Entities:  

Keywords:  Biocompatibility; Biosensors; Immune response; Inflammation; Macrophage

Mesh:

Substances:

Year:  2014        PMID: 25175597      PMCID: PMC4164605          DOI: 10.1016/j.biomaterials.2014.08.002

Source DB:  PubMed          Journal:  Biomaterials        ISSN: 0142-9612            Impact factor:   12.479


  60 in total

1.  Development of a drug screening platform based on engineered heart tissue.

Authors:  Arne Hansen; Alexandra Eder; Marlene Bönstrup; Marianne Flato; Marco Mewe; Sebastian Schaaf; Bülent Aksehirlioglu; Alexander P Schwoerer; Alexander Schwörer; June Uebeler; Thomas Eschenhagen
Journal:  Circ Res       Date:  2010-05-06       Impact factor: 17.367

Review 2.  Thrombin generation and fibrin clot structure.

Authors:  Alisa S Wolberg
Journal:  Blood Rev       Date:  2007-01-08       Impact factor: 8.250

3.  Protein-mediated assembly of nanodiamond hydrogels into a biocompatible and biofunctional multilayer nanofilm.

Authors:  Houjin Huang; Erik Pierstorff; Eiji Osawa; Dean Ho
Journal:  ACS Nano       Date:  2008-02       Impact factor: 15.881

4.  Insulin-stimulated glucose transport in human adipocytes.

Authors:  T P Ciaraldi; O G Kolterman; J A Siegel; J M Olefsky
Journal:  Am J Physiol       Date:  1979-06

Review 5.  Mechanisms, markers and management of coagulation activation.

Authors:  P M Mannucci
Journal:  Br Med Bull       Date:  1994-10       Impact factor: 4.291

6.  Modeling the relative impact of capsular tissue effects on implanted glucose sensor time lag and signal attenuation.

Authors:  Matthew T Novak; Fan Yuan; William M Reichert
Journal:  Anal Bioanal Chem       Date:  2010-08-28       Impact factor: 4.142

7.  Hexose transporter GLUT1 harbors several distinct regulatory binding sites for flavones and tyrphostins.

Authors:  Alejandra Pérez; Paola Ojeda; Lorena Ojeda; Mónica Salas; Coralia I Rivas; Juan C Vera; Alejandro M Reyes
Journal:  Biochemistry       Date:  2011-09-27       Impact factor: 3.162

Review 8.  Initial responses to endotoxins and Gram-negative bacteria.

Authors:  Didier Heumann; Thierry Roger
Journal:  Clin Chim Acta       Date:  2002-09       Impact factor: 3.786

9.  Evidence that erythroid-type glucose transporter intrinsic activity is modulated by cadmium treatment of mouse 3T3-L1 cells.

Authors:  S A Harrison; J M Buxton; B M Clancy; M P Czech
Journal:  J Biol Chem       Date:  1991-10-15       Impact factor: 5.157

10.  Control of cell volume in the J774 macrophage by microtubule disassembly and cyclic AMP.

Authors:  R N Melmed; P J Karanian; R D Berlin
Journal:  J Cell Biol       Date:  1981-09       Impact factor: 10.539

View more
  8 in total

1.  Preclinical Performance Evaluation of Percutaneous Glucose Biosensors: Experimental Considerations and Recommendations.

Authors:  Robert J Soto; Mark H Schoenfisch
Journal:  J Diabetes Sci Technol       Date:  2015-06-17

Review 2.  In Vivo Chemical Sensors: Role of Biocompatibility on Performance and Utility.

Authors:  Robert J Soto; Jackson R Hall; Micah D Brown; James B Taylor; Mark H Schoenfisch
Journal:  Anal Chem       Date:  2016-11-21       Impact factor: 6.986

3.  Preclinical Evaluation of Poly(HEMA-co-acrylamide) Hydrogels Encapsulating Glucose Oxidase and Palladium Benzoporphyrin as Fully Implantable Glucose Sensors.

Authors:  Rachel M Unruh; Jason R Roberts; Scott P Nichols; Soya Gamsey; Natalie A Wisniewski; Michael J McShane
Journal:  J Diabetes Sci Technol       Date:  2015-06-17

4.  Influence of diabetes on the foreign body response to nitric oxide-releasing implants.

Authors:  Robert J Soto; Elizabeth P Merricks; Dwight A Bellinger; Timothy C Nichols; Mark H Schoenfisch
Journal:  Biomaterials       Date:  2017-11-30       Impact factor: 12.479

5.  Impact of CCL2 and CCR2 chemokine/receptor deficiencies on macrophage recruitment and continuous glucose monitoring in vivo.

Authors:  Ulrike Klueh; Caroline Czajkowski; Izabela Ludzinska; Yi Qiao; Jackman Frailey; Donald L Kreutzer
Journal:  Biosens Bioelectron       Date:  2016-06-23       Impact factor: 10.618

Review 6.  Monitoring with In Vivo Electrochemical Sensors: Navigating the Complexities of Blood and Tissue Reactivity.

Authors:  Pankaj Vadgama
Journal:  Sensors (Basel)       Date:  2020-06-02       Impact factor: 3.576

7.  Corrosion Protection of Al/Au/ZnO Anode for Hybrid Cell Application.

Authors:  Gymama Slaughter; Brian Stevens
Journal:  Membranes (Basel)       Date:  2015-11-16

8.  Porous, Dexamethasone-loaded polyurethane coatings extend performance window of implantable glucose sensors in vivo.

Authors:  Suzana G Vallejo-Heligon; Nga L Brown; William M Reichert; Bruce Klitzman
Journal:  Acta Biomater       Date:  2015-10-29       Impact factor: 8.947

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.