CT of the abdomen: degree and quality of enhancement obtained with two concentrations of the same iodinated contrast medium with fixed iodine delivery rate and total iodine load.

Francesco Paparo1, Isabella Garello1, Lorenzo Bacigalupo1, Andrea Marziano1, Athena Galletto Pregliasco1, Ludovica Rollandi2, Cristina Puppo1, Francesca Mattioli3, Matteo Puntoni4, Gian Andrea Rollandi5.   

Abstract

OBJECTIVES: to compare vascular and parenchymal enhancement in abdominal computed tomography (CT) using two iodine concentrations (370 vs 300mgI/mL) of the same contrast medium (CM) molecule (iopromide), using fixed iodine delivery rate (IDR, 1.2gI/s) and total iodine load (630mgI/kg).
METHODS: 144 patients were randomized into two groups: group A receiving iopromide 370 and group B receiving iopromide 300. Attenuation values (AV) were measured in correspondence to key anatomical structures on different phases and compared between groups with parametrical tests. Qualitative analysis was also performed. Peak injection pressure and local discomfort at the site of injection (pain and warmth) were registered.
RESULTS: mean AV of abdominal aorta in late arterial phase were 300.32±59.76 for group A and 298.2±59.14 for group B (p=0.8); mean AV of portal vein in portal phase were 190.5±29.92 for group A and 192.91±24.12 for group B (p=0.6). Mean AV of liver parenchyma in portal phase were 124.73±18.22 for group A and 125.11±15.7 for group B (p=0.9); mean AV of liver at equilibrium were 85.11±7.75 for group A and 85.41±8.09 for group B (p=0.8). Qualitative analysis did not show significant differences between groups (p>0.05). Median peak injection pressure was lower in group B (93psi, 76-172) than in group A (115psi, 88-288, p<0.0001), while discomfort at injection site was not significantly different (p>0.05).
CONCLUSIONS: with fixed IDR and total iodine load, comparable quantitative and qualitative enhancement can be achieved with different concentrations of the same CM. Peak injection pressure increases using CM with higher iodine concentration.
Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.

Entities:  

Keywords:  Abdominal imaging; Computed tomography; Contrast enhancement; Iodinated contrast media; injection pressure

Mesh:

Substances:

Year:  2014        PMID: 25174776     DOI: 10.1016/j.ejrad.2014.07.010

Source DB:  PubMed          Journal:  Eur J Radiol        ISSN: 0720-048X            Impact factor:   3.528


  3 in total

1.  Can Realistic Liver Tissue Surrogates Accurately Quantify the Impact of Reduced-kV Imaging on Attenuation and Contrast of Parenchyma and Lesions?

Authors:  Andre Euler; Justin Solomon; Paul F FitzGerald; Ehsan Samei; Rendon C Nelson
Journal:  Acad Radiol       Date:  2018-09-28       Impact factor: 3.173

Review 2.  Vascular CT and MRI: a practical guide to imaging protocols.

Authors:  D J Murphy; A Aghayev; M L Steigner
Journal:  Insights Imaging       Date:  2018-03-14

3.  The Image Quality and Diagnostic Performance of CT with Low-Concentration Iodine Contrast (240 mg Iodine/mL) for the Abdominal Organs.

Authors:  Moon-Hyung Choi; Young-Joon Lee; Seung-Eun Jung
Journal:  Diagnostics (Basel)       Date:  2022-03-19
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.