| Literature DB >> 25168192 |
Xuzhi Zhang1, Wenwen Liu2, Xun Lu3, J Justin Gooding3, Qiufen Li4, Keming Qu4.
Abstract
Loop-mediated isothermal amplification (LAMP) yields a large amount of DNA, as well as magnesium pyrophosphate precipitate, causing a decrease in ionic strength that can be measured with a conductivity meter. There is a clear relationship between the conductivity of the LAMP mixture solution and the duration of biochemical reaction. Moreover, there is also a clear relationship between the change in conductivity and the amount of initial template DNA over the range of 0.08 to 3.2 ng. These results demonstrate the feasibility not only for detecting the LAMP product qualitatively but also for real-time monitoring the biochemical reaction progression quantitatively using conductivity measurements.Entities:
Keywords: Conductivity; Gene analysis method; Loop-mediated isothermal amplification; Monitor biochemical reaction
Mesh:
Substances:
Year: 2014 PMID: 25168192 DOI: 10.1016/j.ab.2014.08.002
Source DB: PubMed Journal: Anal Biochem ISSN: 0003-2697 Impact factor: 3.365