Literature DB >> 25163423

LSO background radiation as a transmission source using time of flight.

Harold Rothfuss1, Vladimir Panin, Andrew Moor, John Young, Inki Hong, Christian Michel, James Hamill, Michael Casey.   

Abstract

LSO scintillators (Lu2Sio5:Ce) have a background radiation which originates from the isotope Lu-176 that is present in natural occurring lutetium. The decay that occurs in this isotope is a beta decay that is in coincidence with cascade gamma emissions with energies of 307,202 and 88 keV. The coincidental nature of the beta decay with the gamma emissions allow for separation of emission data originating from a positron annihilation event from transmission type data from the Lu-176 beta decay. By using the time of flight information, and information of the chord length between two LSO pixels in coincidence as a result of a beta emission and emitted gamma, a second time window can be set to observe transmission events simultaneously to emission events. Using the time when the PET scanner is not actively acquiring positron emission data, a continuous blank can be acquired and used to reconstruct a transmission image. With this blank and the measured transmission data, a transmission image can be reconstructed. This reconstructed transmission image can be used to perform emission data corrections such as attenuation correction and scatter corrections or starting images for algorithms that estimate emission and attenuation simultaneously. It is observed that the flux of the background activity is high enough to create useful transmission images with an acquisition time of 10 min.

Entities:  

Mesh:

Substances:

Year:  2014        PMID: 25163423     DOI: 10.1088/0031-9155/59/18/5483

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  17 in total

1.  Attenuation correction in emission tomography using the emission data--A review.

Authors:  Yannick Berker; Yusheng Li
Journal:  Med Phys       Date:  2016-02       Impact factor: 4.071

2.  Clinical evaluation of TOF versus non-TOF on PET artifacts in simultaneous PET/MR: a dual centre experience.

Authors:  Edwin E G W Ter Voert; Patrick Veit-Haibach; Sangtae Ahn; Florian Wiesinger; M Mehdi Khalighi; Craig S Levin; Andrei H Iagaru; Greg Zaharchuk; Martin Huellner; Gaspar Delso
Journal:  Eur J Nucl Med Mol Imaging       Date:  2017-01-26       Impact factor: 9.236

Review 3.  From simultaneous to synergistic MR-PET brain imaging: A review of hybrid MR-PET imaging methodologies.

Authors:  Zhaolin Chen; Sharna D Jamadar; Shenpeng Li; Francesco Sforazzini; Jakub Baran; Nicholas Ferris; Nadim Jon Shah; Gary F Egan
Journal:  Hum Brain Mapp       Date:  2018-08-04       Impact factor: 5.038

Review 4.  Advances in PET/MR instrumentation and image reconstruction.

Authors:  Jorge Cabello; Sibylle I Ziegler
Journal:  Br J Radiol       Date:  2016-07-22       Impact factor: 3.039

5.  Joint Reconstruction of Activity and Attenuation in Time-of-Flight PET: A Quantitative Analysis.

Authors:  Ahmadreza Rezaei; Christophe M Deroose; Thomas Vahle; Fernando Boada; Johan Nuyts
Journal:  J Nucl Med       Date:  2018-03-01       Impact factor: 10.057

6.  Quantitative image reconstruction for total-body PET imaging using the 2-meter long EXPLORER scanner.

Authors:  Xuezhu Zhang; Jian Zhou; Simon R Cherry; Ramsey D Badawi; Jinyi Qi
Journal:  Phys Med Biol       Date:  2017-02-27       Impact factor: 3.609

Review 7.  Total-Body PET: Maximizing Sensitivity to Create New Opportunities for Clinical Research and Patient Care.

Authors:  Simon R Cherry; Terry Jones; Joel S Karp; Jinyi Qi; William W Moses; Ramsey D Badawi
Journal:  J Nucl Med       Date:  2017-09-21       Impact factor: 10.057

Review 8.  MR Imaging-Guided Attenuation Correction of PET Data in PET/MR Imaging.

Authors:  David Izquierdo-Garcia; Ciprian Catana
Journal:  PET Clin       Date:  2016-01-26

Review 9.  Advances in time-of-flight PET.

Authors:  Suleman Surti; Joel S Karp
Journal:  Phys Med       Date:  2016-01-06       Impact factor: 2.685

10.  An Accurate Timing Alignment Method with Time-to-Digital Converter Linearity Calibration for High-Resolution TOF PET.

Authors:  Hongdi Li; Chao Wang; Shaohui An; Xingyu Lu; Yun Dong; Shitao Liu; Hossain Baghaei; Yuxuan Zhang; Rocio Ramirez; Wai-Hoi Wong
Journal:  IEEE Trans Nucl Sci       Date:  2015-06-03       Impact factor: 1.679

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.