Literature DB >> 25162561

Mini-implants and miniplates generate sub-absolute and absolute anchorage.

Alberto Consolaro.   

Abstract

The functional demand imposed on bone promotes changes in the spatial properties of osteocytes as well as in their extensions uniformly distributed throughout the mineralized surface. Once spatial deformation is established, osteocytes create the need for structural adaptations that result in bone formation and resorption that happen to meet the functional demands. The endosteum and the periosteum are the effectors responsible for stimulating adaptive osteocytes in the inner and outer surfaces. Changes in shape, volume and position of the jaws as a result of skeletal correction of the maxilla and mandible require anchorage to allow bone remodeling to redefine morphology, esthetics and function as a result of spatial deformation conducted by orthodontic appliances. Examining the degree of changes in shape, volume and structural relationship of areas where mini-implants and miniplates are placed allows us to classify mini-implants as devices of subabsolute anchorage and miniplates as devices of absolute anchorage.

Entities:  

Keywords:  Mechanotransduction; Mini-implants; Miniplates; Orthopedics; Osteocytes; Periosteum

Mesh:

Substances:

Year:  2014        PMID: 25162561      PMCID: PMC4296622          DOI: 10.1590/2176-9451.19.3.020-023.oin

Source DB:  PubMed          Journal:  Dental Press J Orthod        ISSN: 2176-9451


  17 in total

Review 1.  Effects of biomechanical stress on bones in animals.

Authors:  David B Burr; A G Robling; C H Turner
Journal:  Bone       Date:  2002-05       Impact factor: 4.398

2.  The effect of in vivo mechanical loading on estrogen receptor alpha expression in rat ulnar osteocytes.

Authors:  P J Ehrlich; B S Noble; H L Jessop; H Y Stevens; J R Mosley; L E Lanyon
Journal:  J Bone Miner Res       Date:  2002-09       Impact factor: 6.741

3.  Early strain-related changes in enzyme activity in osteocytes following bone loading in vivo.

Authors:  T M Skerry; L Bitensky; J Chayen; L E Lanyon
Journal:  J Bone Miner Res       Date:  1989-10       Impact factor: 6.741

4.  The cellular basis of bone turnover and bone loss: a rebuttal of the osteocytic resorption--bone flow theory.

Authors:  A M Parfitt
Journal:  Clin Orthop Relat Res       Date:  1977       Impact factor: 4.176

Review 5.  Mechanosensation and transduction in osteocytes.

Authors:  Jenneke Klein-Nulend; Astrid D Bakker; Rommel G Bacabac; Aviral Vatsa; Sheldon Weinbaum
Journal:  Bone       Date:  2012-10-18       Impact factor: 4.398

Review 6.  Osteocytes, strain detection, bone modeling and remodeling.

Authors:  L E Lanyon
Journal:  Calcif Tissue Int       Date:  1993       Impact factor: 4.333

7.  A three-dimensional distribution of osteocyte processes revealed by the combination of confocal laser scanning microscopy and differential interference contrast microscopy.

Authors:  H Kamioka; T Honjo; T Takano-Yamamoto
Journal:  Bone       Date:  2001-02       Impact factor: 4.398

8.  Sclerostin is a delayed secreted product of osteocytes that inhibits bone formation.

Authors:  Kenneth E S Poole; Rutger L van Bezooijen; Nigel Loveridge; Herman Hamersma; Socrates E Papapoulos; Clemens W Löwik; Jonathan Reeve
Journal:  FASEB J       Date:  2005-08-25       Impact factor: 5.191

9.  Mechanical loading stimulates rapid changes in periosteal gene expression.

Authors:  D M Raab-Cullen; M A Thiede; D N Petersen; D B Kimmel; R R Recker
Journal:  Calcif Tissue Int       Date:  1994-12       Impact factor: 4.333

10.  Glucocorticoid-treated mice have localized changes in trabecular bone material properties and osteocyte lacunar size that are not observed in placebo-treated or estrogen-deficient mice.

Authors:  Nancy E Lane; Wei Yao; Mehdi Balooch; Ravi K Nalla; Guive Balooch; Stefan Habelitz; John H Kinney; Lynda F Bonewald
Journal:  J Bone Miner Res       Date:  2005-11-14       Impact factor: 6.741

View more
  5 in total

1.  What changes in the biology of bone movement induced with mini-implants/miniplates is the synchronicity.

Authors:  Alberto Consolaro; Ertty Silva; Maurício de Almeida Cardoso
Journal:  Dental Press J Orthod       Date:  2022-07-04

2.  Intrusion of posterior teeth using miniplates: intrusive mechanics is not the same as intrusion force.

Authors:  Suzana T M P M Apolinário; Aparecida Fernanda Meloti; Ertty Silva; Mauricio de Almeida Cardoso; Alberto Consolaro
Journal:  Dental Press J Orthod       Date:  2021-10-25

Review 3.  Effect of local administration of bisphosphonate on orthodontic anchorage - A systematic review of animal studies.

Authors:  Sruthi Harikrishnan; Navaneethan Ramasamy
Journal:  J Orthod Sci       Date:  2022-08-24

4.  Orthodontic camouflage of skeletal Class III malocclusion with miniplate: a case report.

Authors:  Marcel Marchiori Farret; Milton M Benitez Farret; Alessandro Marchiori Farret
Journal:  Dental Press J Orthod       Date:  2016 Jul-Aug

5.  Biomechanical analysis of distalization of mandibular molars by placing a mini-plate: A finite element study.

Authors:  Myungsoon Park; Yonghyun Na; Minbong Park; Janghoon Ahn
Journal:  Korean J Orthod       Date:  2017-07-27       Impact factor: 1.372

  5 in total