BACKGROUND AND OBJECTIVE: Data on record regarding weight variation in depot-medroxyprogesterone acetate (DMPA) and levonorgestrel-releasing intrauterine system (LNG-IUS) users are controversial. To date, no studies have yet evaluated weight variation in DMPA and LNG-IUS users in up to ten years of use compared to non-hormonal contraceptive users. MATERIALS AND METHODS: A retrospective study analysed weight variations in 2138 women using uninterruptedly DMPA (150 mg intramuscularly, three-monthly; n = 714), the LNG-IUS (n = 701) or a copper-intrauterine device (Cu-IUD; n = 723). RESULTS: At the end of the first year of use, there was a mean weight increase of 1.3 kg, 0.7 kg and 0.2 kg among the DMPA-, LNG-IUS- and Cu-IUD users, respectively, compared to weight at baseline (p < 0.0001). After ten years of use, the mean weight had risen by 6.6 kg, 4.0 and 4.9 kg among the DMPA-, LNG-IUS- and Cu-IUD users, respectively. DMPA-users had gained more weight than LNG-IUS- (p = 0.0197) and than Cu-IUD users (p = 0.0294), with the latter two groups not differing significantly from each other in this respect (p = 0.5532). CONCLUSION: Users of hormonal and non-hormonal contraceptive methods gained a significant amount of weight over the years. DMPA users gained more weight over the treatment period of up to ten years than women fitted with either a LNG-IUS or a Cu-IUD.
BACKGROUND AND OBJECTIVE: Data on record regarding weight variation in depot-medroxyprogesterone acetate (DMPA) and levonorgestrel-releasing intrauterine system (LNG-IUS) users are controversial. To date, no studies have yet evaluated weight variation in DMPA and LNG-IUS users in up to ten years of use compared to non-hormonal contraceptive users. MATERIALS AND METHODS: A retrospective study analysed weight variations in 2138 women using uninterruptedly DMPA (150 mg intramuscularly, three-monthly; n = 714), the LNG-IUS (n = 701) or a copper-intrauterine device (Cu-IUD; n = 723). RESULTS: At the end of the first year of use, there was a mean weight increase of 1.3 kg, 0.7 kg and 0.2 kg among the DMPA-, LNG-IUS- and Cu-IUD users, respectively, compared to weight at baseline (p < 0.0001). After ten years of use, the mean weight had risen by 6.6 kg, 4.0 and 4.9 kg among the DMPA-, LNG-IUS- and Cu-IUD users, respectively. DMPA-users had gained more weight than LNG-IUS- (p = 0.0197) and than Cu-IUD users (p = 0.0294), with the latter two groups not differing significantly from each other in this respect (p = 0.5532). CONCLUSION: Users of hormonal and non-hormonal contraceptive methods gained a significant amount of weight over the years. DMPA users gained more weight over the treatment period of up to ten years than women fitted with either a LNG-IUS or a Cu-IUD.
Authors: Marcia A Ciccone; Stephanie A Whitman; Charlotte L Conturie; Niquelle Brown; Christina E Dancz; Begum Özel; Koji Matsuo Journal: Arch Gynecol Obstet Date: 2019-01-31 Impact factor: 2.344
Authors: Laureen M Lopez; Shanthi Ramesh; Mario Chen; Alison Edelman; Conrad Otterness; James Trussell; Frans M Helmerhorst Journal: Cochrane Database Syst Rev Date: 2016-08-28
Authors: Anderson Sanches de Melo; Rosana Maria Dos Reis; Rui Alberto Ferriani; Carolina Sales Vieira Journal: Open Access J Contracept Date: 2017-02-02