Literature DB >> 25154391

Pulse wave analysis with two tonometric devices: a comparison study.

D Agnoletti1, S C Millasseau, J Topouchian, Y Zhang, M E Safar, J Blacher.   

Abstract

Pulse wave analysis is a pivotal tool to estimate central haemodynamic parameters. Available commercial devices use applanation tonometry and have been validated against invasive catheterism. We previously observed differences on a radial second systolic peak (rSPB2) between two commonly used devices: SphygmoCor (AtCor, Australia) and PulsePen (DiaTecne, Italy). The aim of our study was to further quantify differences in radial and carotid signals from the two devices.We measured radial and carotid waveforms in 38 patients with minimal changes between systolic, diastolic blood pressure and heart rate.rSBP2, mean pressure, form factor and augmentation index were different with SphygmoCor providing lower values (mean differences: 2.2 ± 3.8 mmHg; 1.5 ± 1.7 mmHg; 3.2 ± 3.5%; 4.2 ± 8.4%, respectively). Carotid augmentation index and form factor were similar. However carotid systolic pressure (cSBP) from PulsePen was higher than cSBP from SphygmoCor (2.7 ± 4.4 mmHg, p < 0.001). For both carotid and radial signals, harmonics moduli were similar across the spectrum with the exception of the 1st harmonic.PulsePen and SphygmoCor sensors are not equivalent and provide different wave shapes despite similar harmonics content with more discrepancy on radial derived parameters than on carotid derived parameters. Further studies are required to compare invasive pressure parameters to indices derived from these two devices.

Entities:  

Mesh:

Year:  2014        PMID: 25154391     DOI: 10.1088/0967-3334/35/9/1837

Source DB:  PubMed          Journal:  Physiol Meas        ISSN: 0967-3334            Impact factor:   2.833


  7 in total

1.  Measuring the Carotid to Femoral Pulse Wave Velocity (Cf-PWV) to Evaluate Arterial Stiffness.

Authors:  Hongwei Ji; Jing Xiong; Shikai Yu; Chen Chi; Bin Bai; Jiadela Teliewubai; Yuyan Lu; Yi Zhang; Yawei Xu
Journal:  J Vis Exp       Date:  2018-05-03       Impact factor: 1.355

2.  Aortic Pulse Wave Velocity as Adjunct Risk Marker for Assessing Cardiovascular Disease Risk: Prospective Study.

Authors:  Carlos A Valencia-Hernández; Joni V Lindbohm; Martin J Shipley; Ian B Wilkinson; Carmel M McEniery; Sara Ahmadi-Abhari; Archana Singh-Manoux; Mika Kivimäki; Eric J Brunner
Journal:  Hypertension       Date:  2022-02-10       Impact factor: 9.897

3.  Measurement of central augmentation index by three different methods and techniques: Agreement among Arteriograph, Complior, and Mobil-O-Graph devices.

Authors:  Theodore G Papaioannou; John Thymis; Dimitrios Benas; Helen Triantafyllidi; Gavriela Kostelli; George Pavlidis; Fotini Kousathana; Kostantinos Katogiannis; Dimitrios Vlastos; Vaia Lambadiari; Evangelia Papadavid; John Parissis; Dimitrios Tousoulis; Ignatios Ikonomidis
Journal:  J Clin Hypertens (Greenwich)       Date:  2019-08-29       Impact factor: 3.738

4.  Northern Shanghai Study: cardiovascular risk and its associated factors in the Chinese elderly-a study protocol of a prospective study design.

Authors:  Hongwei Ji; Jing Xiong; Shikai Yu; Chen Chi; Ximin Fan; Bin Bai; Yiwu Zhou; Jiadela Teliewubai; Yuyan Lu; Henry Xu; Yi Zhang; Yawei Xu
Journal:  BMJ Open       Date:  2017-03-29       Impact factor: 2.692

5.  Associations between Type 2 Diabetes Mellitus and Arterial Stiffness: A Prospective Analysis Based on the Maine-Syracuse Study.

Authors:  Merrill F Elias; Georgina E Crichton; Peter J Dearborn; Michael A Robbins; Walter P Abhayaratna
Journal:  Pulse (Basel)       Date:  2017-08-26

6.  Less arterial stiffness in kidney transplant recipients than chronic kidney disease patients matched for renal function.

Authors:  Lynda Cheddani; Jean Philippe Haymann; Sophie Liabeuf; Nahid Tabibzadeh; Jean-Jacques Boffa; Emmanuel Letavernier; Marie Essig; Tilman B Drüeke; Michel Delahousse; Ziad A Massy
Journal:  Clin Kidney J       Date:  2020-09-03

Review 7.  Blood Pressure Sensors: Materials, Fabrication Methods, Performance Evaluations and Future Perspectives.

Authors:  Ahmed Al-Qatatsheh; Yosry Morsi; Ali Zavabeti; Ali Zolfagharian; Nisa Salim; Abbas Z Kouzani; Bobak Mosadegh; Saleh Gharaie
Journal:  Sensors (Basel)       Date:  2020-08-11       Impact factor: 3.576

  7 in total