Literature DB >> 25146037

Differences in cyclic fatigue resistance between ProTaper Next and ProTaper Universal instruments at different levels.

Juan J Pérez-Higueras1, Ana Arias2, José C de la Macorra1, Ove A Peters3.   

Abstract

INTRODUCTION: New designs and alloys have been developed to increase cyclic fatigue (CF) resistance of rotary files. The aim of this study was to compare CF resistance of ProTaper Universal (PTU; Dentsply Tulsa Dental, Tulsa, OK) and ProTaper Next (PTN, Dentsply Tulsa Dental) instruments at different points of curvature.
METHODS: A total of 420 files (240 PTU, S1, F1, F2, and F3 and 180 PTN, X1, X2, and X3) were divided in 14 groups of 30 instruments each. Instruments in groups S1-5, F1-5, X1-5, F2-5, X2-5, F3-5, and X3-5 were tested at 5 mm from the tip. Groups S1-12, X1-12, and F1-12 were tested at 12 mm from the tip because S1, X1, and F1 instruments have the same diameter at that level. Groups F2-8, X2-8, F3-8, and X3-8 were tested at 8 mm (F2/X2 and F3/X3, respectively, had the same diameter at 8 mm). All files were rotated at 300 rpm until fracture. CF resistance was tested in stainless steel curved canals (60°, r = 3 mm). Time to fracture was recorded. The mean half-life and beta and eta were calculated for each group and were compared with Weibull analysis.
RESULTS: PTN instruments will last significantly longer than PTU files with a probability higher than 98% at all tested levels except for S1, which was the significantly the most resistant instrument to CF at 5 mm from the tip.
CONCLUSIONS: PTU S1 was significantly the most resistant instrument at 5 mm from the tip. PTN files were significantly more resistant to CF than PTU instruments at all the other tested levels.
Copyright © 2014 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.

Entities:  

Keywords:  Cyclic fatigue resistance; M-Wire; ProTaper Next; ProTaper Universal; Weibull analysis

Mesh:

Substances:

Year:  2014        PMID: 25146037     DOI: 10.1016/j.joen.2014.02.025

Source DB:  PubMed          Journal:  J Endod        ISSN: 0099-2399            Impact factor:   4.171


  14 in total

1.  Performance of NiTi endodontic instrument under different temperatures.

Authors:  Ahmed Jamleh; Yoshio Yahata; Arata Ebihara; Amre R Atmeh; Turki Bakhsh; Hideaki Suda
Journal:  Odontology       Date:  2015-08-22       Impact factor: 2.634

2.  Analysis of the Importance of the Motion Used in the Resistance of Different Mechanical Instrumentation Systems in Endodontics: A Comparative Study.

Authors:  Jesús Mena-Álvarez; Manuel Almanzor-López; Norberto Quispe-López; Ana De Pedro-Muñoz; Cristina Rico-Romano
Journal:  Materials (Basel)       Date:  2022-06-24       Impact factor: 3.748

3.  Evaluation of the Fractured Surface of Five Endodontic Rotary Instruments: A Metallurgical Study.

Authors:  Mohsen Aminsobhani; Mohamad Saleh Khalatbari; Naghmeh Meraji; Abdollah Ghorbanzadeh; Ehsan Sadri
Journal:  Iran Endod J       Date:  2016

4.  Alternating versus continuous rotation: Root canal transportation and centering ratio with the ProTaper Next.

Authors:  Juan González-Chapela; Pablo Castelo-Baz; Purificación Varela-Patiño; Benjamín Martín-Biedma; Manuel Ruíz-Piñón
Journal:  J Conserv Dent       Date:  2017 Jul-Aug

5.  Wear of the Primary WaveOne single file when shaping vestibular root canals of first maxillary molar.

Authors:  Daniel Aracena; Eduardo Borie; Pablo Betancourt; Angella Aracena; Mario Guzmán
Journal:  J Clin Exp Dent       Date:  2017-03-01

6.  The geometric effect of an off-centered cross-section on nickel-titanium rotary instruments: A finite element analysis study.

Authors:  Jung-Hong Ha; Sang Won Kwak; Antheunis Versluis; Chan-Joo Lee; Se-Hee Park; Hyeon-Cheol Kim
Journal:  J Dent Sci       Date:  2017-03-14       Impact factor: 2.080

7.  A comparative study of root canal shaping using protaper universal and protaper next rotary files in preclinical dental education.

Authors:  Gül Çelik; Feyza Özdemir Kısacık; Emir Faruk Yılmaz; Arife Mersinlioğlu; İhsan Furkan Ertuğrul; Hikmet Orhan
Journal:  PeerJ       Date:  2019-08-19       Impact factor: 2.984

Review 8.  Nickel-Titanium Rotary File Systems: What's New?

Authors:  Sadia Tabassum; Kamil Zafar; Fahad Umer
Journal:  Eur Endod J       Date:  2019-10-18

9.  An in vitro cyclic fatigue resistance comparison of conventional and new generation nickel-titanium rotary files.

Authors:  Celia Ruiz-Sánchez; Vicente Faus-Matoses; Teresa Alegre-Domingo; Ignacio Faus-Matoses; Vicente-José Faus-Llácer
Journal:  J Clin Exp Dent       Date:  2018-08-01

10.  Fracture and deformation of ProTaper Next instruments after clinical use.

Authors:  Gema Fernández-Pazos; Benjamín Martín-Biedma; Purificación Varela-Patiño; Manuel Ruíz-Piñón; Pablo Castelo-Baz
Journal:  J Clin Exp Dent       Date:  2018-11-01
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.