BACKGROUND: Graves' disease represents a relative contraindication for robotic thyroidectomy due to increased vascularity with a higher risk of intraoperative bleeding. With a novel robotic instrumentation, however, it is possible to reduce this risk considerably. METHODS: A 30-year-old female patient with Graves' disease and keloid-prone olive skin underwent a single-incision transaxillary robotic total thyroidectomy through the left axilla using an 8-mm Fenestrated bipolar forceps instead of the standard 8-mm ProGrasp forceps. RESULTS: Total blood loss was 25 ml, and robotic console time was 132 min. There was no postoperative recurrent palsy. Postoperative parathormone level was 47 ng/l (preop.: 56 ng/l), and serum calcium level was normal at 2,17 mmol/l (preop.: 2,23 mmol/l). CONCLUSION: Transaxillary robotic surgery (TARS) with unilateral single-incision access is feasible and safe for Graves' disease with minimal blood loss and reduced risk of conversion thanks to the bipolar capability of the 8-mm Fenestrated bipolar forceps.
BACKGROUND:Graves' disease represents a relative contraindication for robotic thyroidectomy due to increased vascularity with a higher risk of intraoperative bleeding. With a novel robotic instrumentation, however, it is possible to reduce this risk considerably. METHODS: A 30-year-old female patient with Graves' disease and keloid-prone olive skin underwent a single-incision transaxillary robotic total thyroidectomy through the left axilla using an 8-mm Fenestrated bipolar forceps instead of the standard 8-mm ProGrasp forceps. RESULTS: Total blood loss was 25 ml, and robotic console time was 132 min. There was no postoperative recurrent palsy. Postoperative parathormone level was 47 ng/l (preop.: 56 ng/l), and serum calcium level was normal at 2,17 mmol/l (preop.: 2,23 mmol/l). CONCLUSION: Transaxillary robotic surgery (TARS) with unilateral single-incision access is feasible and safe for Graves' disease with minimal blood loss and reduced risk of conversion thanks to the bipolar capability of the 8-mm Fenestrated bipolar forceps.
Authors: E Kandil; S Noureldine; M Abdel Khalek; S Alrasheedi; R Aslam; P Friedlander; F C Holsinger; C F Bellows Journal: J Visc Surg Date: 2011-11-25 Impact factor: 2.043
Authors: Sang-Wook Kang; Jong Ju Jeong; Kee-Hyun Nam; Hang Seok Chang; Woong Youn Chung; Cheong Soo Park Journal: J Am Coll Surg Date: 2009-06-12 Impact factor: 6.113
Authors: Sang-Wook Kang; Seung Chul Lee; So Hee Lee; Kang Young Lee; Jong Ju Jeong; Yong Sang Lee; Kee-Hyun Nam; Hang Seok Chang; Woong Youn Chung; Cheong Soo Park Journal: Surgery Date: 2009-10-30 Impact factor: 3.982