Literature DB >> 25137378

Can POCIS be used in Water Framework Directive (2000/60/EC) monitoring networks? A study focusing on pesticides in a French agricultural watershed.

Gaëlle Poulier1, Sophie Lissalde2, Adeline Charriau2, Rémy Buzier2, François Delmas3, Kéwin Gery3, Aurélie Moreira3, Gilles Guibaud2, Nicolas Mazzella4.   

Abstract

In this study, the main current limitations in the application of the Polar Organic Chemical Integrative Sampler (POCIS) in regulatory monitoring programmes were evaluated. POCIS were exposed from March to December by successive periods of 14 days in the River Trec (Lot et Garonne, France) and analysed for 34 pesticides. The study of the uncertainty related to the POCIS data was performed and we concluded that it might be up to 138%, which is higher than European Union requirements but this issue was adequately counterbalanced by the gain of temporal representativeness. Comparison with data from the official monitoring programme from the French Water Agency showed that the POCIS is already suitable for both operational and investigative monitoring. The sampled fraction issue, and then compliance with Environmental Quality Standards, was also addressed. It was confirmed that POCIS samples only the dissolved fraction of dimethenamid and showed that for compounds like atrazine, desethylatrazine and metolachlor, the POCIS concentration is equivalent to the whole water concentration. For dimethenamid, which exhibited a tendency to adsorb on suspended matter, a method was suggested to assess the raw water concentration from the POCIS measure. Finally, an innovative procedure for using passive sampler data for compliance checks in the framework of surveillance monitoring is proposed.
Copyright © 2014 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  POCIS; Pesticides; Sampled fraction; Uncertainty; Water Framework Directive; Water monitoring

Mesh:

Substances:

Year:  2014        PMID: 25137378     DOI: 10.1016/j.scitotenv.2014.08.001

Source DB:  PubMed          Journal:  Sci Total Environ        ISSN: 0048-9697            Impact factor:   7.963


  11 in total

1.  Evaluating polar pesticide pollution with a combined approach: a survey of agricultural practices and POCIS passive samplers in a Tunisian lagoon watershed.

Authors:  Takoua Mhadhbi; Olivier Pringault; Habiba Nouri; Sylvie Spinelli; Hamouda Beyrem; Catherine Gonzalez
Journal:  Environ Sci Pollut Res Int       Date:  2018-11-05       Impact factor: 4.223

2.  Risk estimation and annual fluxes of emerging contaminants from a Scottish priority catchment to the estuary and North Sea.

Authors:  Zulin Zhang; Melanie Lebleu; Mark Osprey; Christine Kerr; Estelle Courtot
Journal:  Environ Geochem Health       Date:  2017-06-28       Impact factor: 4.609

3.  How do PDMS-coated stir bars used as passive samplers integrate concentration peaks of pesticides in freshwater?

Authors:  A Assoumani; C Margoum; A Lombard; C Guillemain; M Coquery
Journal:  Environ Sci Pollut Res Int       Date:  2016-04-28       Impact factor: 4.223

4.  Two sampling strategies for an overview of pesticide contamination in an agriculture-extensive headwater stream.

Authors:  Robin Guibal; Sophie Lissalde; Julie Leblanc; Karine Cleries; Adeline Charriau; Gaëlle Poulier; Nicolas Mazzella; Jean-Pierre Rebillard; Yoann Brizard; Gilles Guibaud
Journal:  Environ Sci Pollut Res Int       Date:  2017-08-26       Impact factor: 4.223

5.  Towards the review of the European Union Water Framework Directive: Recommendations for more efficient assessment and management of chemical contamination in European surface water resources.

Authors:  Werner Brack; Valeria Dulio; Marlene Ågerstrand; Ian Allan; Rolf Altenburger; Markus Brinkmann; Dirk Bunke; Robert M Burgess; Ian Cousins; Beate I Escher; Félix J Hernández; L Mark Hewitt; Klára Hilscherová; Juliane Hollender; Henner Hollert; Robert Kase; Bernd Klauer; Claudia Lindim; David López Herráez; Cécil Miège; John Munthe; Simon O'Toole; Leo Posthuma; Heinz Rüdel; Ralf B Schäfer; Manfred Sengl; Foppe Smedes; Dik van de Meent; Paul J van den Brink; Jos van Gils; Annemarie P van Wezel; A Dick Vethaak; Etienne Vermeirssen; Peter C von der Ohe; Branislav Vrana
Journal:  Sci Total Environ       Date:  2016-10-28       Impact factor: 7.963

6.  Advanced Photocatalytic Treatment of Wastewater Using Immobilized Titanium Dioxide as a Photocatalyst in a Pilot-Scale Reactor: Process Intensification.

Authors:  Abdoulaye Kane; Achraf Amir Assadi; Atef El Jery; Ahmad K Badawi; Hamza Kenfoud; Oussama Baaloudj; Aymen Amin Assadi
Journal:  Materials (Basel)       Date:  2022-06-28       Impact factor: 3.748

7.  Active and passive sampling for the assessment of hydrophilic organic contaminants in a river basin-ecotoxicological risk assessment.

Authors:  Evangelia Terzopoulou; Dimitra Voutsa
Journal:  Environ Sci Pollut Res Int       Date:  2015-11-17       Impact factor: 4.223

8.  "Modern agriculture" transfers many pesticides to watercourses: a case study of a representative rural catchment of southern Brazil.

Authors:  José Augusto Monteiro de Castro Lima; Jérôme Labanowski; Marília Camotti Bastos; Renato Zanella; Osmar Damian Prestes; Jocelina Paranhos Rosa de Vargas; Leslie Mondamert; Eugenie Granado; Tales Tiecher; Mohsin Zafar; Alexandre Troian; Thibaut Le Guet; Danilo Rheinheimer Dos Santos
Journal:  Environ Sci Pollut Res Int       Date:  2020-01-15       Impact factor: 4.223

9.  Calibration and application of the Chemcatcher® passive sampler for monitoring acidic herbicides in the River Exe, UK catchment.

Authors:  Ian Townsend; Lewis Jones; Martin Broom; Anthony Gravell; Melanie Schumacher; Gary R Fones; Richard Greenwood; Graham A Mills
Journal:  Environ Sci Pollut Res Int       Date:  2018-06-25       Impact factor: 4.223

Review 10.  Improving Toxicity Assessment of Pesticide Mixtures: The Use of Polar Passive Sampling Devices Extracts in Microalgae Toxicity Tests.

Authors:  Sandra Kim Tiam; Vincent Fauvelle; Soizic Morin; Nicolas Mazzella
Journal:  Front Microbiol       Date:  2016-09-09       Impact factor: 5.640

View more