Literature DB >> 25130763

Does Biolox Delta ceramic reduce the rate of component fractures in total hip replacement?

P Massin1, R Lopes2, B Masson3, D Mainard4.   

Abstract

UNLABELLED: Biolox Delta ceramic has been optimized with nano-sized, yttria-stabilized tetragonal zirconium and strontium oxide to help limit cracking propagation. Although its mechanical properties are better than those of earlier generation ceramics, existing data on this material are limited, thus the goals of this study were to determine: 1) the remaining rate of implant fracture; 2) the ideal combination of head diameter and component position. Hypothesis. We hypothesized that the use of the ceramic composite Biolox Delta had reduced the risk of implant fracture. Materials and methods. The bibliographic search (in Pubmed database with the key words «ceramic fracture» and «total hip prosthesis ») identified 46 articles on fractures in third or fourth generation ceramic components, including 5 involving Biolox Delta. Manufacturer's data and ANSM (Agence nationale de sécurité du médicament et des produits de santé) (National Agency for Safety of Drugs and Medical Products) reports were compared with the few clinical cases published in the literature. Results. According to the manufacturer (CeramTec GmbH, Plochingen, Germany), the use of Biolox Delta ceramic has reduced the rate of femoral head fractures to 0.003% compared to 0.021% with alumina ceramic. The fracture rate of liners has remained stable, at approximately 0.03%. The number of ANSM reports confirmed these tendencies. The rate of head component fractures decreases as the head diameter increases. The quality of impaction on the morse taper (cleanliness of the taper, insertion along the axis) plays an important role. Although it is generally only available for cup sizes above 50mm, a 36-mm head diameter seems to be optimal because it prevents impingement between the cup rim and the neck of the stem, without increasing micro-separation with larger diameters. Conclusion. Although Biolox Delta ceramic is more resistant to fractures than alumina ceramic, it can be fractured under suboptimal implantation conditions including edge loading. Its use requires the same precautions as other hard-on-hard bearings and requires special attention to cup position, insertion on or in morse tapers and adjustment of leg length. LEVEL OF EVIDENCE: V expert's opinion.
Copyright © 2014 Elsevier Masson SAS. All rights reserved.

Entities:  

Keywords:  Biolox(®) Delta ceramic; Ceramic fracture; Edge loading; Total hip arthroplasty

Mesh:

Year:  2014        PMID: 25130763     DOI: 10.1016/j.otsr.2014.05.010

Source DB:  PubMed          Journal:  Orthop Traumatol Surg Res        ISSN: 1877-0568            Impact factor:   2.256


  30 in total

1.  Revision for taper corrosion at the head-neck junction: pearls and pitfalls.

Authors:  Brian J McGrory; Brigham R McKenney
Journal:  Curr Rev Musculoskelet Med       Date:  2016-03

2.  CORR Insights(®): primary ceramic-on-ceramic total hip arthroplasty using a 32-mm ceramic head with a titanium-alloy sleeve.

Authors:  James A D'Antonio
Journal:  Clin Orthop Relat Res       Date:  2015-06-20       Impact factor: 4.176

3.  Do alumina matrix composite bearings decrease hip noises and bearing fractures at a minimum of 5 years after THA?

Authors:  Seung-Hoon Baek; Won Keun Kim; Jun Young Kim; Shin-Yoon Kim
Journal:  Clin Orthop Relat Res       Date:  2015-12       Impact factor: 4.176

4.  Outcome of Ceramic-on-Ceramic Total Hip Arthroplasty with 4th Generation 36 mm Head Compared to that with 3rd Generation 28 mm Head by Propensity Score Matching.

Authors:  Soong Joon Lee; Kang Sup Yoon
Journal:  Indian J Orthop       Date:  2020-09-02       Impact factor: 1.251

5.  Long-term survivorship of an exchangeable-neck hip prosthesis with a Ti-alloy/Ti-alloy neck-stem junction.

Authors:  Massimiliano Baleani; Aldo Toni; Cristina Ancarani; Susanna Stea; Barbara Bordini
Journal:  Arch Orthop Trauma Surg       Date:  2022-09-30       Impact factor: 2.928

6.  A case-driven hypothesis for multi-stage crack growth mechanism in fourth-generation ceramic head fracture.

Authors:  Stefano Lucchini; Massimiliano Baleani; Federico Giardina; Andrea Martelli; Francesco Castagnini; Barbara Bordini; Francesco Traina
Journal:  J Orthop Surg Res       Date:  2022-06-03       Impact factor: 2.677

7.  Ion release in ceramic bearings for total hip replacement: Results from an in vitro and an in vivo study.

Authors:  Jan Philippe Kretzer; Ulrike Mueller; Marcus R Streit; Hartmuth Kiefer; Robert Sonntag; Robert M Streicher; Joern Reinders
Journal:  Int Orthop       Date:  2017-07-20       Impact factor: 3.075

8.  Do the Reasons for Ceramic-on-ceramic Revisions Differ From Other Bearings in Total Hip Arthroplasty?

Authors:  Henri Migaud; Sophie Putman; Grégory Kern; Ronald Isida; Julien Girard; Nassima Ramdane; Christian P Delaunay; Moussa Hamadouche
Journal:  Clin Orthop Relat Res       Date:  2016-10       Impact factor: 4.176

9.  What Is the Frequency of Fracture of Ceramic Components in THA? Results from the Norwegian Arthroplasty Register from 1997 to 2017.

Authors:  Geir Hallan; Anne Marie Fenstad; Ove Furnes
Journal:  Clin Orthop Relat Res       Date:  2020-06       Impact factor: 4.755

10.  Cobalt toxicity after revision to a metal-on-polyethylene total hip arthroplasty for fracture of ceramic acetabular component.

Authors:  Andrew Harris; Joey Johnson; P Kaveh Mansuripur; Richard Limbird
Journal:  Arthroplast Today       Date:  2015-10-31
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.