Literature DB >> 25130513

Urodynamic testing: physiological background, setting-up, calibration and artefacts.

Orit Raz1, Vincent Tse, Lewis Chan.   

Abstract

Urodynamics (UDS) is an interactive diagnostic study of lower urinary tract function. It is composed of several tests that can be used to obtain functional information about urine storage and expulsion. Its main goal is to reproduce the patients' symptoms and determine their cause. The present article is a review of the physiological concepts behind UDS, and explains the various normal and abnormal forces and parameters that are measured and used during the tests to assist the physician in making a diagnosis. It outlines the importance and methods of the calibration of UDS equipment to optimise diagnostic accuracy and reliability, which would have a crucial impact over the treatment's decision, and consequently the patient's outcome.
© 2014 The Authors. BJU International © 2014 BJU International.

Entities:  

Keywords:  calibration; lower urinary tract; urodynamic

Mesh:

Year:  2014        PMID: 25130513     DOI: 10.1111/bju.12633

Source DB:  PubMed          Journal:  BJU Int        ISSN: 1464-4096            Impact factor:   5.588


  5 in total

1.  Evaluation of voiding assays in mice: impact of genetic strains and sex.

Authors:  Dale E Bjorling; Zunyi Wang; Chad M Vezina; William A Ricke; Kimberly P Keil; Weiqun Yu; Lianyu Guo; Mark L Zeidel; Warren G Hill
Journal:  Am J Physiol Renal Physiol       Date:  2015-04-22

2.  Trained and dedicated staff appears to be the main factor in decreasing anxiety and improving overall satisfaction during urodynamic testing: A prospective, randomized trial.

Authors:  Rose Khavari; Cindy Gu; Anastasia C Tran; Robert Chan
Journal:  Can Urol Assoc J       Date:  2016 May-Jun       Impact factor: 1.862

3.  Measurement of Urinary Bladder Pressure: A Comparison of Methods.

Authors:  Ingelin Clausen; Lars Geir W Tvedt; Thomas Glott
Journal:  Sensors (Basel)       Date:  2018-07-03       Impact factor: 3.576

4.  A novel human cadaver model to investigate a retrourethral transobturator male sling procedure.

Authors:  Sean F Mungovan; William I Jaffe; Petra L Graham; Manish I Patel; Jaspreet S Sandhu
Journal:  Investig Clin Urol       Date:  2019-08-19

5.  Good urodynamic practice: Pressure signal quality immediately after catheter insertion for cystometry with a water-filled pressure transducer system and its relevance for the ICS zero procedure.

Authors:  Peter F W M Rosier
Journal:  Neurourol Urodyn       Date:  2020-11-03       Impact factor: 2.367

  5 in total